• europages
  • >
  • COMPANIES - SUPPLIERS - SERVICE PROVIDERS
  • >
  • air blades

Results for

Air blades - Import export

Manufacturer/producer

Turkey

BKD 100 TYPE AIR DAMPER BKD100 Type Air Dampers; are used for Air Handling Units, Ventilating Ducts, Industrial Air Conditioners to control air volume and to shut-up air movement. Features * Galv. Frame+Al. Blade * Al. Frame+Al. Blade * Stainless Leakage sheet * Manuel or Motorised Control * EPDM or silicone leakage gasket * Fiberglass Nylon Bearing * Parallel or Opposite Blade * Operating Temp.: -20C to 80C.

Request for a quote

Germany

Verified by Europages

AVOLA Circular saw blade HM/A/PH for cutting polystyrene and wood Special benefits of our patented development: One saw blade for two materials For polystyrene (Styrodur and styrofoam) and wood No jamming and sticking, because the newly developed openings in the master blade ensure sufficient air cooling Even without blade replacement More safety and occupational protection Faster, more effective and environmentally friendly operation

Request for a quote

Germany

Verified by Europages

Compressed air blade To monitor the progress of certain processes, there is no alternative but to take frequent samples at the machine itself. This is normally possible only while the product is either moving slowly or stopped, and often results in complicated work-arounds to enable continual production (continuously running winders, etc.). The Samplecut FSC is the solution to the problem. The tried and tested sample cutter Samplecut FSC takes samples from fast running product.

Request for a quote

Germany

Cellular wheel sluices Cellular wheel sluices are used as discharge devices under filters, cyclones and silos, as well as for channelling materials into pneumatic conveying systems. In a special tested version, however, these can also be used at the same time for the explosive decoupling of complex plant systems in the sense of the ATEX regulations. Multi-cutter The multi-cutter is ideally suited for the chopping up of paper or plastic waste strips as well as veneer residues in extraction pipes. It works with a set of fast-rotating, but air-permeable blades. The connection diameter is DN 160 and the motor has a rated drive power of 0.75 KW. In order to be able to definitely assess the usability for the application, it is advisable to provide us with representative material samples. The assessment is also often proven by pilot plant trials. The advantage of this is that the degree of chopping can also be determined. ATEX non-return valves (EX) Non-return valves are passive decoupling elements in pipelines for preventing dust explosion effects from running in the opposite direction to the conveying direction. The non-return valves are type-tested protective systems in accordance with directive 94/9/EC, better known under the synonym ATEX 95. Function In normal operation, the top-mounted flap swims on the air stream in the housing of the non-return valve and in this way is held open. At a standstill the valve flap closes under its own weight and rests on the diagonally cut inflow pipe. If an explosion occurs behind the non-return valve, the air flow direction is reversed due to the increased counter-pressure. This causes the flap to close. The valve flap is additionally pressed against the inflow pipe by the pressure of the explosion, thus reliably sealing the pipeline against an explosion backdraught. These non-return valves function without external energy. The RSK and BPF-M series are available in the sizes DN 160, 200, 250, 280, 315, 355, 400, 450, 500, 560, 600, 630, 710, 800, 900 and 1,000. The two series differ in that they have different versions and application possibilities. The non-return valves, as type-tested protective systems, are sold through Brilex Gesellschaft für Explosionsschutz mbH, Hinterm Gallberg 15-17, D-59929 Brilon; www.brilex.de

Request for a quote

Turkey

PRODUCT INFORMATION DC 421 MS is designed for the strait or angular cutting operations of large size of profiles made of aluminum and PVC materials by means of double head sawing units equipped with Ø 420 mm of saw blades. Two-hand run safety operation Manual adjustment of intermediate tilting angles from 90° to 45° inwards Hydro-pneumatic saw blade feed Cutting accuracy +/- 0.2 mm Manual positioning of cutting units Solid steel construction of the body Conveyor & 2 x pneumatic profile supports Automatically closing safety guards Horizontal pneumatic material clamps to ensure optimum material fixing STANDARD ACCESSORIES • Equiped with Ø 420 mm of saw blades • Roller conveyor & 2 x manual profile supports • 4 x horizontal clamps • Air gun • Spray saw blade lubrication system OPTIONAL ACCESSORIES • Profile Length Stop for cutting short pieces (DKN 70 with digital unit, DKN 71 with ruler) • Machine with the length of 5m and 6m • VCE 1570 Chip vacuum extractor

Request for a quote

Do you sell or make similar products?

Sign up to europages and have your products listed

Add my business

Switzerland

The FlexLiner inserting system stands for reliable and trendsetting insert marketing for newspaper and mailshot producers. The size range, from smaller than A4 up to Nordisch newspaper format as well as a wide variety of product openings such as low folio lap, suckers, or air blades, guarantee a wide and flexible range of applications for newspaper, mailings, and magazine production. The inserting system in the midrange segment enables you to expand your product range by introducing new ideas and groundbreaking business models.

Request for a quote

United Kingdom

Fire and Smoke Dampers play a crucial role in the safety in ducting connected to a heating, ventilation and air conditioning system. They prevent the spread of fire and smoke through ductworks. Fire and smoke dampers are known as shut off dampers this is because the blades inside the metal panels will close and allow no additional air to flow through - the blades are forced to shut, this happens because of a fusible link which is set to trigger at It is a legal requirement to have these dampers tested at a minimum once every two years. Failure to do so can result in a fine, prison sentence and closure of business premises until rectified. AJS offer this essential fire safety service of a full fire & smoke damper testing and certifications with nationwide coverage. All test are carried out by fully qualified and trained technicians. Testing will include: Identify and locate each fire damper Retrofit access doors if any of these are inaccessible Carry out fire damper test

Request for a quote

Denmark

Northern Light® is the most efficient system for disinfection and distribution of clean air*. The product line of patented HVLS fans comes with integrated UVC light in the air blades. The fan silently circulates massive amounts of air across the UVC lamps elegantly integrated on the upper side of the air blades. This effectively deactivates airborne pathogens as they’re continuously exposed to UVC light.

Request for a quote