The dual-channel thermopile is optimized for the measurement of carbon monoxide (CO) through an optical filter with a CWL of 4650 ± 40 nm and a HBW of 180 ± 20 nm. Medical technology, process or room air analysis are typical application fields for the MTS2SENS200 carbon monoxide. The MTS2SENS200 carbon monoxide dual detector is suitable for demanding applications at ambient temperatures from -20 to 85 °C. It has a particularly high detectivity. It has a particularly high detectivity of up to 6.27*10^8 cm√Hz/W and a sensitivity of up to 171 V/W. This signal quality is comparable to pyro detectors. The integrated thermistor for reference temperature determination and an additional reference channel (CWL: 3910 ± 28, HBW: 70 ± 10 nm) complete the product. The detector has as technological basis 2 chips with 200 bismuth antimony/antimony thermocouples each. Other applications of the detector include metabolic monitoring, spirometry, biotechnology and food technology.

Request for a quote

Germany

2 channel premium thermopile sensor for the measurement of hydrocarbons (HC). IR filters with a CWL of 3400 ± 20 nm and a HBW of 140 ± 20 nm and a particularly high detectivity of up to 6.27*10^8 cm√Hz/W as well as a very high sensitivity of up to 171 V/W guarantee precise and long-term stable measurement results. The Thermopile is suitable for demanding industrial applications such as industrial gas measurement, coolant monitoring or process analysis. Two detector chips with 200 bismuth antimony/antimony thermopiles each form the core for this 2 channel thermopile. The signal quality is comparable to that of pyroelectric detectors. The integrated thermistor for reference temperature determination, an interference absorber and an additional reference channel (CWL: 3910 ± 28, HBW: 70 ± 10 nm) optimize the measurement results of the dual IR detector. For this product, customer-specific adaptations are possible as well as agreements on graduated prices.

Request for a quote

Germany

This premium pyroelectric quad detector is tailored for measurement applications for the analysis of nitrogen oxides (NOX) in environments from -20 to 85 °C. The filters determine the infrared detection of the following gases: water vapor (H2O) (CWL: 6580 ± 40, HBW: ± 35 nm), nitric oxide (NO) (CWL: 5300 ± 30, HBW: ± 20 nm), sulfur dioxide (SO2) (CWL: 7300 ± 50, HBW: 180 ± 20 nm) and an embedded reference channel (CWL: 5060 ± 25, HBW: 100 ± 15 nm). The four-channel IR pyrodetector achieves a high detectivity of up to 4.0*10^8 cm√Hz/W and sensitivity of up to 200000 V/W. The MPS4SENS NOX provides reliable measurement values in ambient temperatures between -20 and 85 °C, e.g. for industrial gas measurement or process analysis in various industry and manufacturing areas, such as chemical, textile, environmental technology, recycling or exhaust gas technology. Micro-Hybrid is the only manufacturer of pyroelectric 4-channel detectors with a high performance membrane in a TO39 package.

Request for a quote

Germany

2 channel premium thermopile sensor for the measurement of hydrocarbons (HC). IR filters with a CWL of 3400 ± 20 nm and a HBW of 140 ± 20 nm and a particularly high detectivity of up to 6.27*10^8 cm√Hz/W as well as a very high sensitivity of up to 171 V/W guarantee precise and long-term stable measurement results. The Thermopile is suitable for demanding industrial applications such as industrial gas measurement, coolant monitoring or process analysis. Two detector chips with 200 bismuth antimony/antimony thermopiles each form the core for this 2 channel thermopile. The signal quality is comparable to that of pyroelectric detectors. The integrated thermistor for reference temperature determination, an interference absorber and an additional reference channel (CWL: 3910 ± 28, HBW: 70 ± 10 nm) optimize the measurement results of the dual IR detector. For this product, customer-specific adaptations are possible as well as agreements on graduated prices.

Request for a quote

Germany

The narrow band filter of the MPS2SENS carbon dioxide with a CWL of 4265 ± 25 nm and a HBW of 120 ± 10 nm is optimized for the measurement of carbon dioxide (CO2) with reference channel (CWL: 3910 ± 28, HBW: 70 ± 10 nm). The detector suits for demanding applications in medical, industry and environmental technology. With its very high read-out rate of up to 100 Hz and a short response time, it provides precise measurement results reliably and quickly. The pyrodetector MPS2SENS carbon dioxide is based on 2 chips with a thin film CPM membrane. Thanks to the Ceramic Pyroelectrical Material (CPM) the detector features a very high detectivity of up to 4.0*10^8 cm√Hz/W and sensitivity of up to 200000 V/W. The signal quality of our pyroelectric sensors is unchallenged. The detector operates within ambient temperatures ranging from -20 to 85 °C and covers a wide range of applications: NDIR gas analysis, industrial process and exhaust gas measurement, and respiratory gas monitoring.