• europages
  • >
  • COMPANIES - SUPPLIERS - SERVICE PROVIDERS
  • >
  • gas detectors

Results for

Gas detectors - Import export

GermanyWeimar and ThuringiaManufacturer/producer

Germany

The MicroSENS 180-HS is an NDIR sensor for measuring 5 vol.-% CO2 in cell incubators. So our diffusion sensor is indispensable for controlling ideal cell and tissue growth. The sensor head is placed in the incubation chamber to measure the gas concentration in the cell culture environment. Based on IR absorption of the gas molecules the sensor determines the concentration of CO2. Our CO2 gas sensor convinces with a high reliability and a long lifetime thanks to its specifically developed dual-beam IR method without drift and susceptibility to interference. Decontaminate the CO2 diffusion sensor in an easy, effective and reliable way by heat sterilization at typ. 180 °C. Thanks to the digital and analogue interfaces, the sensor is easy to integrate. Find all technical information in our data sheet. Benefit from precise and reliable measurement of CO2, easy handling and minimal maintenance costs.

Request for a quote

Germany

Verified by Europages

In order to ensure that castings, valves, pumps, hoses and other components or groups have been manufactured free of leakage, they are tested in non-destructive leakage tests. Oxygen, air, nitrogen or sulfur hexafluoride (SF6) can be used as the test medium.

Request for a quote

Germany

2 channel premium thermopile detector for IR gas analysis of nitric oxide (NO) with a CWL of 5300 ± 30 nm and a HBW of 200 ± 20 nm. Application areas of such measurement applications are mainly in the industrial gas measurement of process gases or exhaust gases. The particularly high detectivity of up to 6.27*10^8 cmHz^1/2/W, as well as the very high sensitivity of up to 171 V/W, provide a signal quality comparable to pyroelectric detectors. The integrated thermistor for reference temperature determination, an interference absorber and an additional reference channel (CWL: 3910 ± 28, HBW: 70 ± 10 nm) optimize the measurement results of the dual IR detector. Storage and operation can be performed between -20 and 85 °C. Two sensor chips with 200 bismuth antimony/antimony thermopiles each form the core for the 2 channel thermopile MTS2SENS200 nitrogen monoxide. Due to its high-end materials, the thermopile is particularly durable and delivers precise measurement results.

Request for a quote

Germany

The NDIR bundle HC made by Micro-Hybrid is a set of perfectly matched IR emitters and detectors for hydrocarbon gas analysis which includes a NAC based IR emitter with reflector of the JSIR 350 series, completed with the highly sensitive thermopile dual detector of the MTS 200 series. The optical filter of the detector is adapted to the characteristic wavelength (CWL: 3400 ± 20 nm / HBW: 140 ± 20 nm) range of hydrocarbons. In order to get fast test results in biogas plants or for the development of hydrocarbon probes to control and monitor chemical processes, Micro-Hybrid is the only manufacturer worldwide to offer both infrared components for the analysis of infrared active gases.

Request for a quote

Germany

The pyroelectric detector with 2 channels is precisely made for measuring halothane (C2HBrClF3). With a CWL of 7665 ± 77 nm and a HBW of 242 ± 40 nm, the narrow-band filter combined with a reference channel (CWL: 5060 ± 25, HBW: 100 ± 15 nm) ensures precise results. Its signal strength is exceptional in the range of pyroelectric detectors: High detectivity up to 4.0*10^8 cm√Hz/W and high sensitivity up to 200000 V/W. The MPS2SENS halothane provides reliable detections in environments between -20 and 85 °C, e.g. for anesthetic gas monitoring. The detector features two chips with a thin film membrane made of ceramic pyroelectric material. The high read-out rate up to 100 Hz as well as the short response time ensure precise and fast measurement results for NDIR gas analysis. The low microphone effect, the low temperature dependence as well as the amplified signal in current mode are further important product features for long-term use in demanding medical applications.

Request for a quote

Do you sell or make similar products?

Sign up to europages and have your products listed

Add my business

Germany

The high detectivity up to 4.0*10^8 cm√Hz/W as well as the high sensitivity up to 200000 V/W characterize the MPS2SENS flourane. The optical characteristics of the infrared filter windows perfectly suit the analysis of flouranes (CWL of 8620 ± 45 nm, HBW of 540 ± 45 nm, reference channel with CWL: 5060 ± 25, HBW: 100 ± 15 nm). The MPS2SENS sulfur dioxide provides reliable readings in environments between -20 and 85 °C for NDIR gas measurement in medical applications, e.g. anesthetic gas monitoring. The pyroelectric detector has 2 chips with a thin film CPM membrane in the core. (CPM: Ceramic Pyroelectrical Material). Other key product features for long-term use in demanding applications: wide spectral sensitivity 2 - 15 µm (optimized from 3 - 5 µm), high sensitivity with a modulation frequency of up to 100 Hz, low microphone effect due to the low membrane mass, very low temperature dependence, amplified signal in current mode.

Request for a quote
Filters

Results for

Gas detectors - Import export

Number of results

7 Products