• europages
  • >
  • COMPANIES - SUPPLIERS - SERVICE PROVIDERS
  • >
  • gas analysers

Results for

Gas analysers - Import export

GermanyWeimar and ThuringiaManufacturer/producer

Germany

The NDIR bundle CO2 is a set of perfectly matching components for the gas analysis of carbon dioxide and offers research teams, institutes and laboratories the right solution for the demand of short term required IR components in small volumes. Micro-Hybrid is combining a NAC-based IR emitter with reflector of the JSIR 350 series with the highly sensitive thermopile dual detector of the MTS 2 SENS series. The narrow band filter of the dual detector is optimized to absorb carbon dioxide (CWL: 4265 ± 25 nm / HBW: 120 ± 10 nm) and has an additional reference channel (CWL: 3910 ± 28, HBW: 70 ± 10 nm). Designed for use in research projects in the fields of cell growth, plant cultivation or industrial gas measurement, our NDIR bundle CO2 provides developers with immediate results in gas analysis.

Request for a quote

Germany

The IR Thermopile can be used to measure methanol (CH4O / half structure formula: CH3OH) & ethanol (C2H5OH) at ambient temperatures between -20 and 85 °C. With its very high detectivity of up to 6.27*10^8 cm√Hz/W and a sensitivity of up to 171 V/W, the 2-channel detector is the high end solution for demanding applications in medical technology or industrial production and process applications. The optical filter window with a CWL of 9663 ± 80 nm and a HBW of 240 ± 40 nm is specifically designed for NDIR gas analysis of these typical alcohol compounds. These signal values, which are comparable to pyrodetectors, are achieved by the interaction of chip design, integrated thermistor for reference temperature determination, an interference absorber and backgassing with krypton. The precise measurement results are further secured by the second reference channel (CWL: 5060 ± 25, HBW: 100 ± 15 nm).

Request for a quote

Germany

The narrow-band filter of the MTS2SENS200 carbon dioxide with a CWL of 4265 ± 25 nm and an HBW of 120 ± 10 nm is optimized for the measurement of carbon dioxide (CO2) with reference channel (CWL: 3910 ± 28, HBW: 70 ± 10 nm). The detector is characterized by an integrated thermistor for reference temperature determination and an interference absorber. They both ensure that the signal is converted as efficiently as possible from radiant energy to thermal energy. The basis of the IR thermopile MTS2SENS200 carbon dioxide are 2 chips with 200 bismuth-antimony/antimony thermocouples each. Thanks to them and the filling with krypton, the detector convinces with a detectivity of up to 6.27*10^8 cm√Hz/W and sensitivity of up to 171 V/W. The signal quality is comparable to pyroelectric detectors. The detector can be used at ambient temperatures between -20 and 85 °C in numerous industrial, aerospace and medical applications: Exhaust gas measurement, breath gas analysis or patient monitoring.

Request for a quote

Germany

The NDIR bundle N2O is made up of optimally matched thin film infrared emitters and a corresponding IR thermopile detector to measure nitrous oxide in gas mixes. The kit has a short delivery time and therefore achieves measurement results in a short time. This is especially an advantage for developers in research projects with a limited time span. The two-channel detector's optical filter has been optimized for the absorption spectrum of N2O (CWL: 4525 ± 20 nm / HBW: 83 ± 6 nm) and can provide important data, especially in the analysis of exhaust gases in the automotive, railway and marine sectors, the monitoring of industrial exhaust emissions and environmental monitoring.

Request for a quote

Germany

The 2 channel premium pyrodetector is specially designed for the analysis of nitric oxide (NO). The optical filter with a CWL of 5300 ± 30 nm and a HBW of ± 20 nm as well as an additional reference channel (CWL: 3910 ± 28, HBW: 70 ± 10 nm) optimize the measurement results of the dual IR detector. Its main application lies in the measurement of process gases or exhaust gases in industrial production and process engineering. Storage and operation can take place between -20 and 85 °C. The particularly high detectivity of up to 4.0*10^8 cm√Hz/W as well as the very high sensitivity up to 200000 V/W provide an extraordinary signal quality in the sector of pyroelectric detectors. Two sensor chips with a thin film CPM membrane form the core of the dual detector MPS2SENS nitrogen monoxide. Thanks to the Ceramic Pyroelectrical Material (CPM) and the unique product design the detector features a high read-out rate up to 100 Hz as well as a short response time.

Request for a quote

Do you sell or make similar products?

Sign up to europages and have your products listed

Add my business

Germany

This 2 channel premium pyrodetector offers an optimal performance for the measurement of carbon compounds (CxHy) through the narrowband infrared filter with a CWL of 3400 ± 20 nm and a HBW of 140 ± 20 nm as well as an additional reference channel (CWL: 3910 ± 28, HBW: 70 ± 10 nm). The particularly high detectivity of up to 4.0*10^8 cm√Hz/W as well as the very high sensitivity of up to 200000 V/W guarantee precise and long-term stable measurement results. The pyroelectric detector allows demanding applications in gas measurement and gas analysis in various industries such as aerospace, medical or industrial process technology. Two detector chips with a ceramic pyroelectric thin film diaphragm form the core of this 2 channel pyroelectric detector. The low microphone effect due to the low membrane mass, the very low temperature dependence and an amplified signal in current modes enhance the measurement signals of the dual IR detector.

Request for a quote

Germany

The dual channel pyrodetector is specially designed for the measurement of carbon monoxide (CO) using an optical filter with a CWL of 4650 ± 40 nm and a HBW of 180 ± 20 nm. Medical, industrial gas analysis and environmental technology are typical fields of application for the MPS2SENS carbon monoxide. The dual detector meets demanding needs at ambient temperatures ranging from -20 to 85 °C. It has a particularly high detectivity of up to 4.0*10^8 cm√Hz/W and sensitivity of up to 200000 V/W. An additional reference channel (CWL: 3910 ± 28, HBW: 70 ± 10 nm) completes the product. The detector is equipped with 2 chips with a thin film membrane made of ceramic-pyroelectric material as technological basis. The unique detector design of Micro-Hybrid enables the high read-out rate up to 100 Hz as well as the short response time and guarantees precise and fast measurement results for NDIR gas analysis.

Request for a quote

Germany

The dual-channel thermopile is optimized for the measurement of carbon monoxide (CO) through an optical filter with a CWL of 4650 ± 40 nm and a HBW of 180 ± 20 nm. Medical technology, process or room air analysis are typical application fields for the MTS2SENS200 carbon monoxide. The MTS2SENS200 carbon monoxide dual detector is suitable for demanding applications at ambient temperatures from -20 to 85 °C. It has a particularly high detectivity. It has a particularly high detectivity of up to 6.27*10^8 cm√Hz/W and a sensitivity of up to 171 V/W. This signal quality is comparable to pyro detectors. The integrated thermistor for reference temperature determination and an additional reference channel (CWL: 3910 ± 28, HBW: 70 ± 10 nm) complete the product. The detector has as technological basis 2 chips with 200 bismuth antimony/antimony thermocouples each. Other applications of the detector include metabolic monitoring, spirometry, biotechnology and food technology.

Request for a quote

Germany

The MTS2SENS200 sulfur dioxide is tuned by its filter window for the analysis of sulfur dioxide (SO2) with a CWL of 7300 ± 50 nm and a HBW of 180 ± 20 nm. The signal strength of the detector is comparable to that of a pyro detector - high detectivity of up to 6.27*10^8 cm√Hz/W and high sensitivity of up to 171 V/W with krypton as filling gas. The dual-channel IR thermopile for NDIR gas analysis has 2 chips in the core, each with 200 BiSb/Sb thermopairs. The interference absorber, an integrated thermistor for reference temperature determination and the reference channel (CWL: 5060 ± 25, HBW: 100 ± 15 nm) are further important product features for long-term use in demanding applications. The MTS2SENS200 sulfur dioxide provides reliable measurement values in environments between -20 and 85 °C, e.g. for biotechnology or quality assurance. Our sales team will be happy to discuss further scale prices and possible individual customizations with you.

Request for a quote
Filters

Results for

Gas analysers - Import export

Number of results