• europages
  • >
  • COMPANIES - SUPPLIERS - SERVICE PROVIDERS
  • >
  • heating ovens

Results for

Heating ovens - Import export

GermanyWeimar and Thuringia

Germany

Plunger Force Adjustment Video Tutorial ILS glass syringes are manufactured to exacting standards and are quality tested to meet or exceed our minimum performance specifications for accuracy and precision. Our testing methods are in accordance GLP protocols and utilize equipment that is traceable to NIST standards. Copies of actual test result are available upon request. Syringe use: - eliminate the carry over between the samples. Rinse the syringe with the to be examined liquid 10-20 times. Wash the syringe and discard the first 2 -3 washes. - for injection overfill the microlitersyringe. Press the plunger until the accurate volume. Syringe cleaning - pull the piston out of the glass body of the microsyringe - rinse inside the glass body with detergents (in the final rinsing cycle it is best to use a low boiling point, solvent or alcohol) - dry the glass body by air flow, e.g. with a vacuum pump CAUTION: DO NOT IMMERSE THE MICROSYRINGE IN THE SOLVENT: THE GLUE PARTS CAN BE SOLVED. Needle blocked: - use the cleaning wires from ILS you find a wide range at www.microsyringes.com Plunger with seal - if you want reduce the plunger force, heat the assembled syringe in oven at 60°C 15 minutes - Silicone or other lubricants that are compatible with your sample may also be used to wet the plunger tips CAUTION: RUNNING A TEFLON-TIPPED PLUNGER DRY MAY CAUSE THE PTFE TO SHRED OR PULL LOOSE FROM THE PLUNGER ROD, RESULTING IN LEAKS. Plunger Tip ss*=stainless steel (N- Series) -clean the plunger in an ultra sonic bath - wipe the piston with a fibre-free cloth (i.e. no paper towel) Plunger of zero dead volume syringes (T- Series) - loose the nut before pull out or insert the plunger - wipe the piston with a fibre-free cloth (i.e. not paper towel)

Germany

Device details: ■ 2 in 1: device contains the Hot Set Test as well as the Heat Pressure Test ■ Robust and compact set including the device and an equipment case ■ Possibility to attach a thermometer directly near the sample ■ Measurement according to the standards IEC EN 60811-507 (Hot Set Test) and IEC EN 60811-508 (Heat Pressure Test) regarding sample attachment and weight attachment ■ Precise choice of weights due to practical containers ■ Simultaneous measurement of up to 3 samples Optional - Hot Set Test complete ■ Sample rack for heat pressure and heat elongation test ■ Laser gauge ■ Thermal heat oven UN55 Size (WxLxH): 585 x 514 x 784 mm (23 x 20.2 x 30.9“) Weight: 57 kg (125.6 lbs) Volumen: 53 l Air exchange rate: 8-20x ■ Thermal heat oven UN110 Size (WxLxH): 745 x 584 x 864 mm (29 x 23 x 34“) Weight: 74 kg (163 lbs) Volumen: 108 l Air exchange rate: 8-20x

Request for a quote

Do you sell or make similar products?

Sign up to europages and have your products listed

Add my business
Filters

Results for

Heating ovens - Import export

Number of results

2 Products