• europages
  • >
  • COMPANIES - SUPPLIERS - SERVICE PROVIDERS
  • >
  • process calibrators

Results for

Process calibrators - Import export

Germany

Germany

Verified by Europages

The DIGISTANT® model 4420 universal calibrator, built to use in the field, is ideal for checking and calibrating temperature measurement and control devices. The versatile functions of this portable unit allow to be used on-site or at a fixed location, on the test floor or in the laboratory. The unit allows the simulation and measurement of voltages, currents, temperatures and resistances.Simultaneous transmission and measurement allow, for example, controllers to be checked precisely. The automatic ramp function is used for controlling processes. The universal calibrator measures and simulates 14 models of thermocouples and Pt100. Features: Calibration and measurement unit for voltages, currents, temperatures and resistances All functions can be fully controlled and configured via RS232 interface Simultaneous transmission and measurement Automatic ramp function Simple menu assistance via display Voltage range ± 1 μV to ± 11.000 V Current range ± 200 nA to ± 22.000 mA

Request for a quote

Germany

Verified by Europages

Absolut transducer for precise measuring and control applications with integrated signal processing. Replaceable without new calibration.

Request for a quote

Germany

Verified by Europages

With the software Z+F SynCaT®, Zoller+Fröhlich creates a connection between the Z+F PROFILER® 9012 and external positioning and navigation systems. SynCaT stands for synchronization, calibration and transformation - also representing the main tasks of the software. Z+F SynCat® includes all the features below: Calibration: Processing of calibration parameters due to different system integrations (translation, rotation offsets between the coordinate systems of the navigation-unit (trajectory) and the Z+F PROFILER® 9012 laser scanner) Synchronization: Synchronize Z+F PROFILER® 9012 laser scanner data with trajectory data and generate 3D point cloud files Transformation: Transform 3D point cloud data to different local coordinate systems and apply different local/global height correction models (geoid correction files) Correction: Individual offset estimation referring to predefined ground control points (GCP’s) Z+F SynCaT® is a modular structured mobile mapping software.

Request for a quote

Germany

Verified by Europages

The digital pressure gauge DM 01 is a precision device fulfilling highest demands. It was conceived especially for the process monitoring and calibration. The advantage: With the digital display DM 01, different pressure transmitters can be used for various measurement ranges. Outstanding measuring qualities, an intuitive operation, as well as an innovative, modular sensor concept characterise the DM 01. The battery-powered digital pressure gauge can be used e.g. for controlling pressure courses or calibrating pressure transmitters. Features: — nominal pressure: 0 ... 100 mbar up to 0 ... 400 bar — accuracy: 0.05 % FSO BFSL (class 0.05) — modular sensor concept — graphics-capable display — background illumination — communication interface USB 2.0 — stainless steel housing d = 100 mm — zero point calibration — data logger Optional Features: — accredited calibration certificate — IS-version zone 0/1

Request for a quote

Germany

Over the last few years, we at EP-E have designed and introduced a series of primary standards for gases, designed for use in calibration laboratories. As a technology partner of the Physikalisch-Technische Bundesanstalt (PTB) in Braunschweig, our solutions are based on the highest standards. The EP gas bell plungers generate a volume flow which is traceable to the SI units length and time. The pistons are driven by a stepper motor via a spindle. In the initial state one piston is fully retracted and the other fully extended. The volume flow can be set with high precision via the piston cross section and the travel speed. At the end of the calibration process, both pistons are in the opposite position to the initial position. The calibration device is preferably operated with air, which can be supplied with up to 6 bar. The EP gas bell pistons convince by highest measuring accuracy up to 0.15% (k=2).

Request for a quote

Do you sell or make similar products?

Sign up to europages and have your products listed

Add my business

Germany

High accuracy certified through serious accuracy calibration process Faster scanning speed Make high resolution 3D modeling accessible to professional users Meet your demands for highquality 3D modeling of reverse engineering and design

Request for a quote

Germany

The resistance thermometer is suited for operation on tanks and pipes. All standard types of process connections are available. The change in resistance, dependent on the measurement temperature, can be detected by a transmitter and converted into a standardized signal. A variety of transmitters for head mounting is available for different applications. For In-process calibration the integration of a special measuriung insert with additional test pipe is possible (data sheet T4-025-45,Type GA3100, reference sensor: data sheet T4-025-46, Type GA3110).

Request for a quote

Germany

Resistance thermometer Pt 100 without thermowell - GA2500 Features: Resistance thermometer for additional thermowell Pt 100 connection 3- and 4-wire technology Measuring insert interchangeable Measuring insert 1 x Pt 100 or 2 x Pt 100 Various designs available Options: Explosion protection Classification per SIL2 Approval German Lloyd Transmitter can be integrated Measuring insert for In-process calibration

Request for a quote

Germany

The resistance thermometer is suited for operation on tanks and pipings especially in hygienic applications. All standard types of process connections are available. Because of its robust design it is suitable for use in a great number of technological processes. The change in resistance, dependant on the measurement temperature, can be detected by a transmitter and converted into a standardized signal. A variety of transmitters for head mounting is available for different applications. For In-process calibration the integration of a special measuriung insert with additional test pipe is possible (data sheet T4-025-45,Type GA3100, reference sensor: data sheet T4-025-46, Type GA3110).

Request for a quote