Premium infrared emitter with a high performance nanoamorphous carbon membrane. This achieves membrane temperatures of up to 850 °C for high and long-term stable radiation output. The JSIR 350 IR emitter is ideal for various gas analysis applications in medicine, industry and other demanding application fields. The packaging version in the standard TO39 housing with reflector is suitable for measurement distances from 2 cm. The combination of filling gas (nitrogen) and optical window (CaF2) optimizes the emission in the wavelength range from UV to 12 µm. The emitter can be used with MTS thermopile detectors or with MPS pyro detectors. The combination with Micro-Hybrid IR detectors guarantees optimum performance and ensures precise measurement results for the analysis of gas concentrations. Our sales team will be happy to advise you on customization and scale prices for high volumes. For further technical information please refer to the data sheet.

Request for a quote

Germany

Premium infrared emitter with a high performance nanoamorphous carbon membrane. This achieves membrane temperatures of up to 850 °C for high and long-term stable radiation output. The JSIR 350 IR emitter is ideal for various gas analysis applications in medicine, industry and other demanding application fields. With a very low input power of 175 mW, this infrared radiation source can also be used for mobile devices and hand held devices. The combination of filling gas and the optical window (CaF2) optimizes the emission in the wavelength range from UV to 12 µm. The packaging version in the standard TO46 housing with reflector is suitable for measurement distances from 2 cm. The emitter can be used with MTS thermopile detectors or with MPS pyro detectors. The combination with Micro-Hybrid IR detectors guarantees optimum performance and ensures precise measurement results for the analysis of gas concentrations. For further technical information please refer to the data sheet.

Request for a quote

Germany

Premium infrared emitter with a high performance nanoamorphous carbon membrane. This achieves membrane temperatures of up to 850 °C for high and long-term stable radiation output. The JSIR 350 IR emitter is ideal for various gas analysis applications in medicine, industry and other demanding application fields. The packaging version in the standard TO39 housing with reflector is suitable for measurement distances from 2 cm. The combination of filling gas (nitrogen) and optical window (BaF2) optimizes the emission in the wavelength range from UV to 14 µm. The emitter can be used with MTS thermopile detectors or with MPS pyro detectors. The combination with Micro-Hybrid IR detectors guarantees optimum performance and ensures precise measurement results for the analysis of gas concentrations. Our sales team will be happy to advise you on customization and scale prices for high volumes. For further technical information please refer to the data sheet.

Request for a quote

Germany

Premium infrared emitter with a high performance nanoamorphous carbon membrane. This achieves membrane temperatures of up to 850 °C for high and long-term stable radiation output. The JSIR 350 IR emitter is ideal for various gas analysis applications in medicine, industry and other demanding application fields. The packaging version in the standard TO39 housing with reflector is suitable for measurement distances from 2 cm. The combination of filling gas and optical window (Sapphire) optimizes the emission in the wavelength range from UV to 5.5 µm. The emitter can be used with MTS thermopile detectors or with MPS pyro detectors. The combination with Micro-Hybrid IR detectors guarantees optimum performance and ensures precise measurement results for the analysis of gas concentrations. Our sales team will be happy to advise you on customization and scale prices for high volumes. For further technical information please refer to the data sheet.

Request for a quote

Germany

The IR Thermopile can be used to measure methanol (CH4O / half structure formula: CH3OH) & ethanol (C2H5OH) at ambient temperatures between -20 and 85 °C. With its very high detectivity of up to 6.27*10^8 cm√Hz/W and a sensitivity of up to 171 V/W, the 2-channel detector is the high end solution for demanding applications in medical technology or industrial production and process applications. The optical filter window with a CWL of 9663 ± 80 nm and a HBW of 240 ± 40 nm is specifically designed for NDIR gas analysis of these typical alcohol compounds. These signal values, which are comparable to pyrodetectors, are achieved by the interaction of chip design, integrated thermistor for reference temperature determination, an interference absorber and backgassing with krypton. The precise measurement results are further secured by the second reference channel (CWL: 5060 ± 25, HBW: 100 ± 15 nm).

Request for a quote

Do you sell or make similar products?

Sign up to europages and have your products listed

Add my business

Germany

Edmund Optics features the world’s largest inventory of off-the-shelf Optical Components, including a wide selection of Optical Lenses, Optical Filters, Optical Mirrors, Windows, Prisms, Beamsplitters, or Diffraction Gratings. Optical Lenses are designed for focusing or diverging lighting. Optical Filters are used to selectively pass or block a specific wavelength or wavelength range. Optical Mirrors, Prisms, or Beamsplitters split or alter the path of light. Windows are used to protect sensitive components such as electronic detectors or sensors from outside environments.

Request for a quote
Filters

Results for

Optical windows - Import export

Number of results

7 Products