• europages
  • >
  • COMPANIES - SUPPLIERS - SERVICE PROVIDERS
  • >
  • laser equipment

Results for

Laser equipment - Import export

GermanyMunich, Nuremberg and BavariaManufacturer/producer

Germany

Verified by Europages

Many materials cannot be measured tactilely, therefore non-contact thickness measurements become necessary. Especially e.g. with glowing materials, or wet processes, a continuous tactile measurement is nearly impossible. Furthermore, web speeds in plant engineering and production have increased, requiring a corresponding fast sampling rate of the measuring systems. In addition, high measuring widths are often required. Why is contact free measurement technology so perfect for this application? Can be used in any web width, Scalable measurement thicknesses from a few millimetres to several meters, Thickness and coating thickness can be measured for different materials, Vibrations of the web materials, can be compensated, Turnkey solution for mechanical engineering, Non-contact and non-destructive measurement method, Large distances to the measured object are possible, Measurement of free forms,

Request for a quote

Germany

Verified by Europages

The QuellTech laser sensor family Q4 or Q5 used for these tasks is generally mounted on an arm of a rotational axis, to scan along the complete 360° angle of the internal surface in a sequence of strips. The Q4 sensors can also be used to control the weld seam tracking itself for rapid setup and ease of use. Even during a project, the range and scope of the Q Series sensor demonstrates the advantages of a modular system to quickly adapt to project needs, where the smallest system has provided fast analysis of pipes as small as 105mm. The low power, with standard communication protocols, enable battery powered systems to transmit wireless data to other systems for review and cloud back up.

Request for a quote

Germany

Verified by Europages

Particular Challenges of the Application: By tactile equipment, determination of the deepest point on a rough metal surface is neither simple or precise. As a consequence, often either too much material is removed, or the surface is still covered with defects which have to be eliminated by a following milling cycle. The equipment is arranged in parallel, so that the complete width of the slabs is covered. The sensors are calibrated to a common coordinate system and mounted on a movable gantry. Before measurement, the slabs are fixed in place. The scanners mounted on the gantry are guided over the measuring object, driven by an electric motor. The point cloud recorded by the four scanners is consolidated in a PC by means of the QuellTech image processing software which calculates the difference between highest and lowest point of the corresponding surface and compensates for possible inclination of the slab (detrending).

Request for a quote

Germany

Verified by Europages

The optoNCDT BL models are equipped with a blue laser diode and are used when standard sensors with a red laser diode are operating at their performance limits. Due to its shorter wavelength, the blue laser does not penetrate the target surface, projecting a small light spot on the surface and therefore providing stable and precise results. As Blue Laser sensors are equipped with a special filter, they are insensitive to highly emitting objects such as glowing metals. Blue Laser sensors are preferably used with measurements on organic and (semi-)transparent objects, as well as for red-hot glowing metals.

Request for a quote

Germany

The ALFlak systems offer you many options in the field of mobile laser and repair welding. With an extended range and increased travel range, welding positions in deep, complex shapes can be processed easily thanks to the long laser arm - even in deep, bulky shapes. Deposition welding with wire or powder is possible with this laser machine. Likewise, automated welding tasks. The laser device is equipped with a fiber source that guarantees high efficiency and a special beam quality. Both pulsed and CW mode can be used. The integrated performance monitoring ensures reproducible welds. This system is available with laser powers of 300/450/600 and 900 watts.

Request for a quote

Germany

The wavelength meters of the WS series accomplish wavelength measurements with highest accuracy. Both cw and pulsed lasers with narrow-band emission can be examined, monitored and even actively controlled. Various models of the WS series are available, covering UV to IR wavelength ranges (192 nm - 11 µm). Based on a rugged Fizeau interferometer setup without any moving components, the wavelength meters provide quasi unlimited lifetime.The spectrum analyzers LSA and HDSA allow for multi-line or broadband spectrum of light sources like cw and pulsed lasers, gas discharge lamps, super luminescence diodes, semiconductor laser diodes and LEDs.

Request for a quote

Do you sell or make similar products?

Sign up to europages and have your products listed

Add my business