• europages
  • >
  • COMPANIES - SUPPLIERS - SERVICE PROVIDERS
  • >
  • gas installation

Results for

Gas installation - Import export

GermanyMunich, Nuremberg and Bavaria

Germany

Verified by Europages

— For the reliable fuel supply with gas — Preassembled for fast installation — Rigorous compliance with official requirements — Increased operating reliability — Also for biogas- and hydrogen-fuelled systems Highly efficient boiler systems with perfectly matched boiler house components ensure that low levels of energy consumption and emissions are achieved.

Request for a quote

Germany

Combustible Gas Detection - upgrade to upper class! Monitoring the environment for explosive gases most of the time you would be looking for hydrocarbons. It is a characteristic of hydrocarbons that they have a number of C - H bonds. These bonds absorb infrared light at a wavelength of 3,4 mm ( unsaturated hydrocarbons absorb at 3,3 mm ). This effect can be used to reliably detect these substances The most important advantage is that they are resistant against catalyst poisons and high concentrations. They can even be used in oxygen free atmosphere. Another important advantage of this technology is that a failure cannot go unnoticed. If an important component such as the lamp or the detector fails, the system will recognise this as 100 % absorption (an alarm situation). Most infrared gas detectors are designed as so - called NDIR (Non Dispersive Infra Red) double- beam detectors. This means, the light beam is divided in two portions with different wavelengthes. One is the measuring beam that will be absorbed by gas, the other is a reference beam at a wavelength that will not be absorbed by gas. This beam compensates for intensity variations of the lamp, dirt and corrosion. As the optics are mostly self maintained, an eventual inspection only checks if there is gas access to the sensor. Therefore much longer maintenance intervals compared to the catalytic sensor can be justified. As a rule of thumb, twice as long is OK. For plants which already have installed a combustible gas detection system, there is now a chance for a very cost- effective upgrade: The Statox 501 LC IR or LC MR! It consists of an EEx e (enhanced safety) terminal box and a sensor with integrated electronics. This sensor operates at the same supply voltage as a catalytic sensor. Its output signal is also identical to the signal of a catalytic sensor! This new innovative technical approach keeps the price in the same ballpark as catalytic sensors! All advantages of an infrared gas detector are now available for nearly the same price as a catalytic sensor and existing gas detection systems can now be upgraded without replacing the existing hardware. Of course the miniaturised chip inside the sensor cannot provide the same powerful electronics and software package as a high- end instrument, but however the new Compur Statox 501 IR LC features the most important advantages of an infrared system. So the next time maintenance is due with your gas detection system, check with Compur Monitors. The investment for an upgrade might pay back within one maintenance interval.

Request for a quote

Germany

Compur Statox 502 Control - and Common Alarm Module The All – Rounder in Gas Detection No matter if you want to detect toxic or combustible gases: This control module works with any sensor head. It provides the power supply and processes the signal. Three highly rated relays and a 4 – 20 mA output are the interfaces to peripheral instrumentation. Potential front ends may be the Statox 501 or Statox 505 transmitters with electrochemical or infrared sensors, or sensor heads with a Wheatstone bridge signal such as Statox 501 PID, catalytic or the Statox 501 LC and MC series with infrared sensors. Just by the push of a button you can program the module to handle 4 – 20 mA sink or source. Even the bridge voltage can be set to any value between 2 and 5.2 V, it even works with sensor heads of other manufacturers. So there is no restriction at all when selecting the appropriate sensor head for you application. With its two “sense” lines it can even compensate the voltage drop in the cable for very remote sensor heads or if there are extreme temperature variations. For maximum flexibility the measuring range is user programmable. You can also select the unit, no matter if it is ppb, ppm, % LEL or % volume. Easy installation The control module is mounted on a standard DIN rail. With an optional power rail you can interface the 24 V DC power and the alarm signals. This way you can program one of the modules to operate as a common alarm module. Even this function can be programmed just by push button. The application of a control module as a common alarm module is a very useful feature. It displays when any of the modules goes into Alarm 1, 2 or system alarm, and controls peripheral alarm devices. All electrical contacts are located easily accessible on the front side. The terminals for alarm signals, analog output, sensor head connection run into 6 pluggable terminal blocks. This makes not only the first installation quick and easy, but also any service event or system modification. A module can easily be removed out of its row, without interrupting its neighbors or disconnecting wires. Intuitive User Interface You want a gas detection system that needs little or no attention. No matter if setting the initial parameters or performing scheduled calibrations or proof tests: The handling shall be safe, quick and easy. The password - protected Statox 502 software structure is so clear that most menu items are self - explanatory. The “Reset” button brings you time back into the measuring mode at any time. Even if you have to interrupt your work and forget to reset, the watchdog function returns the system into the measuring mode, if no button has been pushed for a while. Functional safety paired with utmost system flexibility The Statox 502 complies with the standards DIN EN 61508 and 61511 functional safety, level SIL 2. In context with the HRC or ARE sensor heads you can create a complete gas detection system for combustible gases complying with SIL 2 standard. In larger installations signals of gas detectors often run into SIL certified process control systems, in smaller plants there is a need for a control module complying with SIL requirements. As any combination sensor head / control module forms a complete gas detection system, this system closes the gap. It is expandable without limits, and there is no restriction to the mix of sensor heads connected. Connecting other front ends The versatility of the Statox 502 does not end with gas detection. You can connect any front end providing a 4 – 20 mA analog signal or a Wheatstone bridge signal. So you can create your own compact control system for a variety of sensors with just one type control device. Accessories Useful accessories such as calibration adapters, intrinsically safe repeaters, Power supplies etc. complete the system. 205 VAC, 8 A min. make or break power >/= 12 V, 10 mA, contakte silver / nickel

Request for a quote

Do you sell or make similar products?

Sign up to europages and have your products listed

Add my business
Filters

Results for

Gas installation - Import export

Number of results

3 Products