• europages
  • >
  • COMPANIES - SUPPLIERS - SERVICE PROVIDERS
  • >
  • detector

Results for

Detector - Import export

GermanyMunich, Nuremberg and Bavaria

Germany

Verified by Europages

Piping and hoses, for example steel bottles, compressors, breathing devices, oxyacetylene gas and inert-gas arc welding devices and burners Fittings, flanges, valves, screwed connections, soldered and welded connections of pressure gas systems and lines Suitable for compressed air, refrigerant, acetylene, butane, natural gas, carbon dioxide, gaseous oxygen, propane, town gas, nitrogen, hydrogen and, ammonia Advantages and benefits Acts non-corrosive Allows direct visual inspection of the leakage point through bubble formation Also available as spray version OKS 2801 Spray version tested by the DVGW in accordance with DIN EN 14291 Spray version suitable for spraying overhead

Request for a quote

Germany

Verified by Europages

CONVEYOR SYSTEM FOR THE EXAMINATION OF ROUND LOGS IN THE LUMBER YARD. Optimal partner for the metal detector METRON 05 CO Low maintenance and long – living construction Tailor made for perfect integration

Request for a quote

Germany

Verified by Europages

Mid-Range tunnel metal detector with integrated control panel used for the inspection of packed, bulk or web products. - Detects all metals encapsulated or as loose parts. - High sensitivity in all industrial environments. - User friendly and reliable technology, proven for many years. - Used either in quality control or for machine protection. - Specifically tailored system solutions with reliable conveying technology and selected accessories.

Request for a quote

Germany

Verified by Europages

Piping and hoses, for example steel bottles, compressors, breathing devices, oxyacetylene gas and inert-gas arc welding devices and burners Fittings, flanges, valves, screwed connections, soldered and welded connections of pressure gas systems and lines Suitable for compressed air, refrigerant, acetylene, butane, natural gas, carbon dioxide, gaseous oxygen, propane, town gas, nitrogen, hydrogen and, ammonia Advantages and benefits Acts non-corrosive Allows direct visual inspection of the leakage point through bubble formation Tested by the DVGW in accordance with DIN EN 14291 Suitable for spraying overhead

Request for a quote

Germany

Verified by Europages

Leak detector high detection sensitivity for pressurised piping and containers, e.g. on compressors, steel bottles, fittings, shut-off valves, breathing devices, oxyacetylene gas and inert-gas arc welding devices, Bunsen burners, valves, screw fittings of compressed-air lines etc. Suitable for compressed air, refrigerant, acetylene, butane, natural gas, carbon dioxide, gaseous oxygen, propane, town gas, nitrogen, hydrogen and, ammonia Suitable for checking the safety of systems with combustible gases and for avoiding financial losses through unrecognized leaks Advantages and benefits Frost-proof to -15°C Saves energy and warns of gas loss Contains corrosion protection inhibitors Tested by the DVGW in accordance with DIN EN 14291 Non-combustible Economical in use

Request for a quote

Germany

DTS 226 C-T 3,35x2,2

Request for a quote

Germany

DTS 201 C P-T 3,5x2,8

Request for a quote

Germany

Germany

DTS 209 CPR-T 3,5x3,3

Request for a quote

Germany

DTS 209 BR-T 3,5x3,3 NC

Request for a quote

Germany

DTS 209 BPR-T 3,5x3,3 NC

Request for a quote

Germany

DTS 204 C-T 3,5x3,3

Request for a quote

Germany

DTS 204 C P-T 3,5x3,3

Request for a quote

Germany

Carbon dioxide detection in industrial plants: Measuring range 0 – 5 % or 0 – 2 % vol. For Martians – provided they exist – a carbon dioxide atmosphere might be their natural habitat. We earthlings can only tolerate low concentrations of this gas. It is true that we are using the special properties of CO 2 for many purposes, but in concentrations above 5000 ppm it can be hazardous to our health. Therefore it must be monitored. In areas that are rarely accessed, such as beverage dispensing facilities, a leak detector might do as a warning device. Wherever people are present, such as workplaces in plants, industrial grade gas detection equipment is required. Here it is: Statox 501 IR. This new version of the field proven Statox 501 IR for combustible gases operates as a 4 – 20 mA transmitter. It can be connected directly to a recording device, process control system, or the optional Statox 501 controller. Its unmatched compact design makes it operable in any environment whether it is food industry, chemical industry, refineries, or cleaning facilities. This explosion proof instrument will do the job everywhere. It is water proof (rated IP 67). The housing materials (stainless steel and fiber-reenforced polyamide) are rugged and easy to clean.

Request for a quote

Germany

Statox 501 Infratox detects gases in the LEL and ppm range. Protecting people and assets from hydrocarbons The infrared absorption method of gas detection is ideal to detect hydrocarbons such as fuels. It features enough sensitivity to expand the range of application into the ppm range. For instance fuels such as gasoline, diesel or kerosene are mixtures of hydrocarbons. Infrared gas detection theory of operation Some gases absorb light at a certain wavelength (colour). This absorption band is specific to the gas. The rate of the absorption depends not only on the substance to be detected but also on the number of gas molecules (i.e. the concentration of the gas). This premise is used to detect gases. For example, the C - H bond in hydrocarbon molecules will oscillate and absorb light at 3, 4 mm. This fact makes it so easy to detect fuels. Hexane, for instance has 14 C - H bonds compared to Methane which has only 4! A light beam is directed through a cuvette filled with the gas to be detected. The more hydrocarbons are present, the more light will be absorbed. A photo detector at the other end of the cuvette measures the remaining light intensity. The difference between the original and remaining light intensity corresponds to the gas concentration. A reference beam with a different wavelength compensates for potential interferences of dust, humidity or variations of intensity from the light source. Fail-safe technology Failure of important components such as the light source or photo detector will trigger a "system fail" alarm. Most local authorities will accept this as a self-diagnostic feature. Systems including a self-check require less maintenance and calibration, saving time and money. Simple maintenance: Easy to read display and non-Vintrusive calibration The bright LED display of the Statox 501 Infratox shows the gas concentration in percent L.E.L. (Lower Explosion Limit). An important accessory is the calibration adapter, featuring control buttons operating Hall-sensors inside the Ex d housing. The service menu is password protected preventing unauthorised access. All parameters can be checked and changed, or a calibration can be done all without opening the transmitter. The adapter is also equipped with a gas outlet so that it can be used for flow-through applications. Impervious compact design The dimensions of the Statox 501 Infratox are small and compact. The sensor compartment is completely sealed, not allowing dust or insects to enter. It is located in the center of the sensor head. This allows heat radiation from the electronics and the infrared lamp to keep the unit a few degrees above the ambient temperature thus avoiding condensation. This innovative design makes any additional heating unnecessary, allowing the sensor head to be very energy efficient. This saves additional money by eliminating more expensive wiring and a bigger power supply that would otherwise be necessary. The sensor head is rated protection class IP 67 (6 = protection even against fine dust, 7 = submerged 1 m deep in water for 30 minutes). You can have confidence that this system will safely operate even in the harshest environment.

Request for a quote

Germany

You always know what is going on in your plant: Gas detection system Statox 505 compliant to SIL 2 Standard Intelligent Gas Sensors for AsH 3, Cl 2, ClO 2, CO, COCl 2, H 2, H 2S, HCl, HCN, HF, N 2H 4, NH 3, NO 2, O 2, O 3, PH 3 and SO 2 The Statox 505 new 4 – 20 mA Transmitter for toxic gases and oxygen features everything that a new gas detection instrument of the latest generation needs: State of the Art components (hardware and software), smart sensor technology, “heartbeat” sensor control and complete system diagnostics on board. What makes the Statox 505 so reliable? In process monitoring, the status of plant components in case of a failure is becoming more and more a critical issue. The standards DIN EN 61508 as well as the product standard DIN EN 50402 are powerful tools to calculate the probability of a failure on demand. The Statox 505 complies with all of the requirements of these standards. It obtained the safety integrity level SIL 2. This provides a reliable database for the user to calculate the safety standard of his plant. If the Statox 505 is operated as a SIL 2 component, a so called “proof test” in certain time intervals is mandatory. All OK All important parameters such as sensor „heartbeat“, signal output, calibration, zero, sensitivity, temperature, sensor memory, amplifier, CPU, power supply etc. are continuously monitored for proper function. In case of a failure, an alarm will be triggered. Thus the system cannot fail without the error being noticed. A green LED signalizes the system status. The display and the controls are located at the inside of the housing - well protected from the elements. Minimum time and work in the field The sensors of the Statox 505 are plug and play technology. Each sensor has a F-RAM on board which communicates all relevant parameters to the sensor head: Gas, measuring range, last calibration, ex works calibration, response time etc. The sensors can easily be calibrated in the shop. For the user this means that he never ever will have to do calibration work in the harsh elements (wind, rain, cold, heat). No more lugging heavy test equipment and gas cylinders into the field. All the user has to do in the field, is plug the sensor back in. To do that, you don`t even need a tool! While the sensor is getting calibrated in the shop, the sensor cartridge stays in place and protects the sensor head from dust and rain. Trouble- free wall - or pipe mounting The Statox 505 comes with a mounting plate for either wall - or pipe mounting. No need to open the sensor head for plant installation Storage temperature

Request for a quote

Germany

Tracer – Leak detection in the ppb range Application The Tracer has its strength where other methods of leak detection would fail, because they have cross sensitivities to other gases. Such selectivity is requested in plants using or producing extremely toxic substances. These plants always have a „Zero Emission Policy“ in force. Here high sensitivity in combination with good selectivity is required. Sensor technology Electrochemical sensors can be designed to be very selective and sensitive at the same time by the right material choice for electrodes and electrolyte. These sensors will not respond to less dangerous substances that might be around in the plant such as hydrocarbons, carbon monoxide, hydrogen or even humidity. A detection limit of Phosgene as low as 2 ppb is no problem for this sensor technology! The Tracer is capable to detect even the smallest traces of toxic gases. The detection limit is in the low ppb range depending on the substance to be detected. As a leak detector might be exposed to very high concentrations, it must not be used as a personal monitor. To avoid it being abused as such, it displays no concentration, but only a dimensionless figure or a bar graph. Using the Tracer To locate a leak, move the sample intake along the surface to be inspected. The measured value will increase when a leak is approached. The display can be selected between bar graph and digital. A control tone and LED will increase in frequency with increasing measured value similar to a Geiger counter. The Tracer will protect itself from poisoning. If the measured value goes out of range the pump will go off and start again when it drops below 95% of the range. The graphic display is easy to read. At night or in dark places in the plant a backlight can be switched on. Consumables such as sensor, filter or sampling probe can easily be replaced without tools. Field test results – the high range version The first tests in plants have proven that an ultra-low measuring range does not always do the job. Therefore Compur Monitors has completed the Tracer product range by a new HIGH range version. It uses an orifice in front of the sensor increasing the measuring range by a factor of 20. The user can do that without changing the amplifier adjustment. All it takes is just replacing the LOW range sensor by a HIGH range sensor and so cover a measuring range from the low ppb range up to the two digit ppm level! The Tracer comes with 4 AA size disposable batteries. This version is not explosion proof. Ex Version Upon request the tracer can be delivered in an explosion - proof version with rechargeable batteries.

Request for a quote

Do you sell or make similar products?

Sign up to europages and have your products listed

Add my business

Germany

Fixed gas detection system for oxygen, toxic and combustible gases This DIN – rail mounted modern control module saves space, money and installation time. One safe controller for all gases: Any combination of a sensor head plus control module is a complete gas detection system. This makes the Statox 501 so safe and reliable. The Statox 501 also gives you the opportunity to alter or expand existing systems with minimum cost and labor. Programs for all gases and measuring ranges are permanently stored in the memory of the controller. The user-friendly software program allows authorized personnel to select different configurations by a simple push of a button. Easy to install and easy to use The controll modules as well as the power supply and the common alarm module clip on to a DIN rail. The remote sensor heads and any alarm or recording devices connect to terminals on the front of the module. Each Statox 501 control module has three relays for alarm 1 and 2 and system failure (115 / 230 V AC / 2 A). An analog output for recorder or process control systems is also included. Measured values are displayed on a 4 digit LED-display. It is easy to program or calibrate the Statox 501! Just follow the menu! If intrinsically safe transmitters are to be installed in division 1 areas, they can be connected via intrinsically safe repeaters. 24 V power supply as well as the signals for the common alarm module are transmitted via bus from one module to the next. All terminals are easily accessible from the front. Field proven sensors for reliable gas detection Compur manufactures electrochemical sensors for the detection of oxygen deficiency and toxic gases. These sensors generate an electrical current proportional to the actual gas concentration. The remote sensor heads are designed as intrinsically safe certified 4 - 20 mA transmitters and have an integrated concentration display. Combustible gases can be detected with a variety of catalytic beads (pellistors) or infrared technology. The sensor heads are certified "Ex d" or "Ex de" and can be connected directly to the control module, even if they are to be used in classified areas. The control module can supply and operate different designs of catalytic sensors. With so many possibilities, the system can easily be tailored to suit your individual application needs. Easy maintenance saves time and money Maintenance of the 4 – 20 mA transmitters is very easy. A one-man calibration or replacement of the sensors can be done without further precautions, even in classified areas. Accessories A range of wall-mount cabinets for a maximum of 5, 8 or 32 controllers as well as a 19”-carrier, ensure an easy professional installation. -20 - +60 °C

Request for a quote

Germany

The Statox 560 might be one of the safest gas detectors at all. Functional safety level 2 tells you how low its probability of failure on demand is. Furthermore a self test with the target gas assures that a failure - how unlikely ever - can never go unnoticed. The fact, that the self test is not only capable detecting a failure, but also maintenance request. This saves a lot of time for inspections. The Statox 560 is in any aspect a state - of - the - art product: - The new sensor generation features high sensitvity, fast response, low interferences and plug - and play technology. - The gas generators produce the target gas and thus offer a 100 % proof that the all components are in perfect condition. - The output signal is either a 4 - 20 mA analog signal or a RS 485 signal. - The electronics are well protected in an Ex d housing with window. The self test can be triggered in programmable time intervals, or manually with a magnetic pin. With this tool you can also set parameters without opening the housing. No hot work permit required! - The sensor module holds the sensor, the generator cell and a micropump. It is an Ex i module, i. e. for work on this module there is also no hot work permit required! The module can be replaced completey by another. This design reduces the work in the field to an absolute minimum. The Statox offers 100 % safety plus utmost operator conveniance! The Statox 560 will come to the market end of 2015. Self test

Request for a quote

Germany

TOPTICA's beat detection consists of two flexible modules: DFC BC and DFC MD. Separating beam combination and beat detection into two units allows for placing them at different locations. The DFC BC and DFC MD units are specifically designed for a combination of the DFC with TOPTICA's DL pro tunable diode laser series, but can also be used with other cw lasers.

Request for a quote

Germany

1.Standard Equipment DP1 Valve Leak Detector including a set of seven adapter plates, a flexible extension hose and a sturdy storage case. 2. Working Principle Applying an air pressure of about 6 bar to the DP1 Valve Leak Detector results in a max. vacuum of about 850 mbar which is applied via an adapter plate to the inlet or exhaust port of the cylinder head to check the respective valve for leakage. The vacuum gauge at the DP 1 indicates the tightness of the valve.

Request for a quote