CheMobil made of PMP/TPX can be used for many substances due to its good chemical resistance. Not suitable for strong acids, alkalis and solvents. CheMobil can be steam sterilised. Flow indicators give precise visual indication of the flow velocity of liquids or gases being transported through hose connections. The flow indicator with impeller functions in both directions and in any position. The impeller starts to rotate at a flow rate about 150 ml/min (liquids).

Request for a quote

Germany

Your benefits User friendly Flexibility for different needs Compact design Many possibilities for installation Convenient for all our flowmeter range Solid, resistant and long term robustness Areas of application The universal converters are used as flow indicators and for batching control of miscellaneous liquids: water, industrial liquids, fuel etc.. These converters are designed for industrial environments. Four versions are available: flow totaliser F113, differential flow measurement F116/F127 with temperature compensation and batching control F131 (non explosive environment) and F131 Exi (explosive environment).

Request for a quote

Germany

Verified by Europages

EGE amplifier complement the EGE flow sensors without integrated amplifier. They process the signals of a measuring sensor and visualise the flow state using an LED indication. In addition, they provide switching or analogue outputs for flow and temperature to the control. The device set-up is easy and takes place using a potentiometer or the buttons on the front. The devices are installed in a control cabinet or comparable protected housing. The EGE amplifier of product series SKM 420; SKM 520; SKM 552 are suitable for supply with 24 V DC or 230/115 V AC.

Request for a quote

Germany

Analogue flow indicators for measuring the flow rate of fluids in mobile and industrial hydraulics. The SDMKR is designed with a loading valve for the strain test of the hydraulic system to facilitate precise control of the operating pressure. In addition, this product can also be subjected to a reverse flow direction (without flow rate determination). ▪ Suitable for Mineral Oil (Aluminium), HFC Fluids and Water (Brass) ▪ Designed for in-line installation ▪ Mechanical flow measurement ▪ Controlling working pressure with a pressure control valve (only SDMKR) ▪ Flow indication in l/min and GPM for Aluminium units, Brass units have flow indication for Water and Oil both in l/min ▪ Aluminium unit: Dual scale ▪ Brass unit: Single scale ▪ Thread to connect with pressure gauge (only SDM) Accuracy (at a kinematic viscosity of 28cSt): ▪ Flow: ±4 % FSD ▪ Temperature: ±2,5 °C / ±5 °F ▪ Pressure (only SDMKR): ±1.6 % FS* ▪ Temp. measuring range: +20 °C ... +110 °C / +55 °F ... +245 °F ▪...

Request for a quote

Germany

Flow sight glasses type N880A-K (DIN length F1) connection with ANSI flanges & with indicator flap

Request for a quote

Do you sell or make similar products?

Sign up to europages and have your products listed

Add my business

Germany

Flow Sight Glass Type Type N880-SOW with pipe – socket – weld connection Use: The flow indicators are used for optical control of fluids and gases, for horizontal and vertical pipe-lines. Also available with internal spinner or flap.

Request for a quote

Germany

STAUFF BPS Bypass Filter can be used for OEM first fit applications as well as for retro-fitting. The filtration is done in a bypass configuration from the main hydraulic system.. Clogging Indicator (available as an option) ▪ Visual clogging indicator Valves ▪ Flow control valve Filter Elements ▪ Filter Elements of SRM series Construction ▪ Bypass Filter Units are especially designed for mobile applications in hydraulic and/or transmission systems ▪ No special motor/pump unit neccessary ▪ Single or double housing Nominal Flow Rate ▪ Max. 4,2 l/min / 1.1 US GPM Max. System Volume ▪ Up to 1.500 l / 400 gal Port Connections ▪ G1/4, G1/2 Materials ▪ Anodised Aluminium Media Compatibility ▪ Mineral or lubrication oils, others on request

Request for a quote

Germany

The Flo-Tronic Plus™ is based on a standard Flo-Meter™ with or without a manual flow control valve. It provides visual flow rate indication as required by NFPA as well as an analog output in direct relation to the flow rate. The Waukee new magnetic flow sensing technology is immune to problems associated with dirty oil. Ideal for customers who need to data log flow rates for compliance to NADCAP, AMS 2750D, or CQI 9. FEATURES • Meets NFPA requirements for visual indication of flow • Isolated 4-20mA current loop output • Over current and reverse polarity protection • Calibrated in our ISO/IEC17025-2005 Calibration Lab and traceable to NIST (National Institute of Standards and Technology) • Multipoint calibration • Simple Installation • Modbus/TCP communications • 1 Programmable relay out • Easily connects to any PLC or controller with differential or single ended analog inputs • Retrofittable to most existing Waukee Flo-Meters

Request for a quote

Germany

Stainless steel heating circuit distributor, with adjustable flow indicators for supply flow and thermostat valve inserts for return flow, incl. wall bracket and draining set

Request for a quote

Germany

CHARACTERISTICS high operating safety robust, compact design pressure resistant up to 350 bar easy maintenance flow direction selectable drag indicator as standard Dual scale bar / psi or mbar / kPa universally applicable selectable display indicating range OPTIONS helium application on demand plastic housing stainless steel housing static pressure max. 450 bar GENERAL The differential pressure gauge DP 900 serves to monitor the differential pressure of filter systems, measuring systems, valves, coolers, heat exchangers, in petrochemical, as well as in gas and air systems. Preferably, the DP 900 is applicable for air and gas technical systems. The gauge housing made from aluminum is designed compact and robust. It is pressure-resistant up to 350 bar. FUNCTION A determined path of a freely movable piston measures the differential pressure. The piston retains against a compression spring. The magnetic spool-measuring device unit is been installed to the main housing.

Request for a quote

Germany

Softcontrol RM monitors the soft water produced by the softener for increased hardness concentrations and also triggers the regeneration of the softener in terms of quality. The monitoring of variable water hardness limit values from 1 ppm to 18 ppm takes place as well as the quality-controlled triggering of the regeneration of two columns of the softener. A continuous measurement takes place as long as water flows. Indicators are dispensed with and low-maintenance ion-selective sensors are used instead. The device has self-monitoring so that, in the event of service, information is provided automatically for less maintenance. The measured values are output on the display, via a 4 to 20 mA current loop and via a LAN data interface with Modbus / TCP. The data is also saved in the electronic operating log (USB stick). Installation and parameterization is easy to carry out on the device.

Request for a quote

Germany

Softcontrol Data offers individual setting options and a clear presentation of the information on the display. The device is a comprehensive alarm system for upstream water softening systems with high safety requirements for the soft water quality. The limit values ​​for the water hardness can be set in the range from 1 ppm to 18 ppm based on the input water hardness. The measurement data and service messages are automatically saved in the readable, integrated USB stick and transmitted via a current loop and LAN interface with MODBUS / TCP. For increased operational and process reliability with the best user friendliness. A continuous measurement takes place approx. 2 times per minute as long as water is flowing. indicators are not used and an ion-selective sensor is used instead. This monitors itself and indicates the required exchange itself. This is usually the only maintenance on the device that has to be carried out around twice a year.

Request for a quote

Germany

Control valve and Flow indicator for use with calibration gas cylinder. Flow meter markings are nominally 0.5 & 1.0 litres/min.

Request for a quote