• europages
  • >
  • COMPANIES - SUPPLIERS - SERVICE PROVIDERS
  • >
  • flexible tubing

Results for

Flexible tubing - Import export

GermanyMainz and Rheinland-PfalzManufacturer/producer

Germany

The 1+ connector consists of just two parts, the connector body and the pressure screw. The clamping ring is incorporated into the pressure screw. The thread and connecting sleeve are integrated inside in the connector body. They cannot be damaged and are thus protected against external effects. Further advantages: The connector is completely leak-proof when it is "hand-tight" and no tools are required. This significantly reduces assembly times. The pressure screw can also be tightened with a fork wrench so there is no gap between the connection and the connector body.

Request for a quote

Germany

The flexible tube is pushed onto the connecting sleeve manually, causing the flexible tube to widen. To secure the connection against shear stresses, torsional stresses or longitudinal forces, you must use, e.g., a pipe clip to fasten the flexible tube in place on the connecting sleeve.

Request for a quote

Germany

The flexible tube is pushed onto the integrated connecting sleeve of the 1A flexible tube con-nector. By tightening the knurled nut, the clamping ring presses against the flexible tube and fixes it in place. The connecting sleeve for the flexible tube is nearly cylindrical. Its dimensions are calculated to prevent tube strain over 6%, even with poor tolerances. The tension produced by the low tube strain is sufficient by itself to guarantee a tight flexible tube connection up to 6 bar. The clamping ring and knurled nut secure the connection against longitudinal forces which could otherwise pull the flexible tube off the connecting sleeve. The clamping ring is designed to secure the flexible tube in place by intercepting any shear or tor-sional stresses. This allows for usage up to 10 bar*. Thanks to its elasticity, the clamping ring can be used several times in the same connector.

Request for a quote

Germany

The firm flexible tube or plastic pipe is pushed onto the integrated connecting sleeve of the 1C connector. The sealing ring forms a tightness for the connection, while it is secured in place by a cutting ring. Due to the knurled nut, this also affects the flexible tube. The cutting ring wedges into the flexible tube or pipe as far as the knurled nut is screwed onto the connector body. A shear force is applied here that intensifies the contact pressure. This creates a friction-locked and tight connection that can be released at any time and minimises the dead volume.

Request for a quote

Germany

In the luer lock adapter 3L, a luer lock thread to DIN EN 20594-1 or ISO 594 (male or female) is combined with our connection for flexible tube 1A, connection for pipe 2M, a Tri-Clamp connection or a G, NPT or UNF male thread. A flexible tube can thus be connected, e.g., to the most commonly used disposable laboratory filters.

Request for a quote

Germany

This connector is specially designed for mesh-reinforced flexible tubes. As all of the Generation+ connectors, it consists of only two parts: the connector body and the pressure screw. The clamping ring is incorporated into the pressure screw. An extra clamping ring is not required. The thread and connecting sleeve are integrated inside in the connector body. The advantage: they cannot be damaged and are protected against external effects.

Request for a quote

Germany

The special design of the 1W+ makes it possible to slide the corrugated flexible tube directly onto the slightly conical connecting sleeve inside the connector body. Then when the pressure screw is threaded in, the corrugated flexible tube is fixed in place on the connecting sleeve. No extra clamping ring is necessary because it is integrated into the pressure screw. That means the connector consists of only two parts, which makes handling considerably easier.

Request for a quote

Germany

The flexible tube is widened when it is pushed onto the integrated connecting sleeve of the 1B flexible tube connector. The tube is secured in place by means of a knurled nut acting on the flexible tube and the connecting sleeve. The connector permanently has a pressure stage of PN 10. Easily able to withstand a brief pressure peaks of up to 30 bar at T= 20°C.

Request for a quote

Germany

Our inline filter is intended for pipeline installation. It is small, compact and low cost. It is easy to replace under practical conditions and can be subsequently retrofitted with no problems. They are also suitable for a variety of applications in different sizes and materials.

Request for a quote

Germany

The 1M micro connector was developed especially for medical, pharmaceutical and analytical technology. It provides ideal connection features for PFA, silicon or Tygon® flexible tubes. The micro connector consists of a connector body with integrated conical connecting sleeve, a knurled nut for fixing the flexible tube and a slotted pressure ring. The pressure ring can be omitted for PFA flexible tubes.

Request for a quote

Germany

The coupling can be shut off to allow for an easy and reliable connection. There is usually a risk of aggressive gases or liquids escaping during coupling operations. Supply lines can be connected and disconnected quickly and frequently with the 3K quick connector because the lock seals off the line before the coupling is undone. To connect or disconnect the coupling, simply actuate the sliding sleeve.

Request for a quote

Germany

The flexible tube for the connector 1D is first thermally widened and then pushed on the integrated connecting sleeve. The tube is secured in place by means of a knurled nut acting on the flexible tube. Thanks to the form-fit connection between the connecting sleeve and flexible tube, the connector has no dead volume.

Request for a quote

Germany

The nipple can be shut off to allow for an easy and reliable connection. There is usually a risk of aggressive gases or liquids escaping during coupling operations. Supply lines can be connected and disconnected quickly and frequently with the 3K quick connector because the lock seals off the line before the coupling is undone.

Request for a quote

Germany

The 3G glass thread apapter is used as a connecting element between the laboratory glass cylinder with GL thread and the connection for flexible tube. The connector features a rotating nut with GL thread on the one hand and a G male thread or connecting elements on the other hand. Various connection elements, flexible tubes and pipes can be fitted in this way.

Request for a quote

Germany

The tube filter is a compact, economical and versatile filter available either as a particle filter or as a coalescence filter. It is easy to use and filter changes can be made quickly. It is fitted with an female thread and is also available with a shut-off or drain feature. In the COMPACT version, the tube filter is already equipped with integrated flexible tube connectors.

Request for a quote

Germany

Our 3E inlay connector can be directly fastened to existing fittings with DIN 8063 male threads and is immediately ready for use with both flexible tubes and pipes. The inlay component of the 3E connector is manufactured as one piece with the connector integrated. This saves not only time and work, it helps to ensure that the connector is tight and thus safe to use.

Request for a quote

Germany

Our pump connection connector offers various connection options for pipes and flexible tubes for the most commonly used dosing pumps of numerous pump manufacturers. For example, diaphragm and hose pumps with an M20x1.5 male thread can be connected directly and leak-proof. The inlay component is manufactured from a single part with the connector integrated, which eliminates time-consuming welding.

Request for a quote

Do you sell or make similar products?

Sign up to europages and have your products listed

Add my business

Germany

For the 2N pipe connector, the pipe is placed against the inner edge of the connector and a sealing ring seals off the connection. A cutting ring wedges into the flexible tube or pipe as far as the knurled nut is screwed onto the connector body, thereby fixing the connection in place. This creates a friction-locked and tight pipe connection that can be released at any time, that eliminates dead volume in the design concept and also has no effect on the flow. The inside diameter of the connector does not correspond to the inside diameter of the pipe.

Request for a quote

Germany

The new 8C compact manifold is especially impressive for its small size. In the single-sided version it can have 2 - 5 outlets, in the double-sided version 2, 6, 8, or 10 outlets. The outlets can be designed to customer specification either with integrated connections for flexible tubes series 1+ in sizes DN04/06 or DN06/08, or with threads G1/8" or G1/4". The side endpieces (input/output) of the manifold can be sealed or fitted with G3/8" or G1/2" threads.

Request for a quote

Germany

The pipe or tube of the 2D pipe connector is inserted through the connector as required for bead tubes, immersion tubes, thermometers or sensors, etc. The pipe is placed against the inner edge of the connector and a sealing ring seals off the connection. A cutting ring wedges into the flexible tube or pipe as far as the knurled nut is screwed onto the connector body, thereby fixing the connection in place.

Request for a quote
Filters

Results for

Flexible tubing - Import export

Number of results

21 Products