• europages
  • >
  • COMPANIES - SUPPLIERS - SERVICE PROVIDERS
  • >
  • signalling systems

Results for

Signalling systems - Import export

GermanyKiel and Schleswig-Holstein

Germany

Verified by Europages

Based on our rotary solenoid D2, Kendrion offers a wide range of highly reliable optical shutters for blocking light and laser beams in the field of optical safety technology. The optical shutter D23 forms the technical basis with remarkable properties and can be used in a wide range of applications, e.g. in medical instruments, aeronautical instruments, fiber optic signal transmission systems and in mass photometry. The D23 optical shutter impresses with maximum reliability, durability and a fast switching time of approx. 15 ms. With at least 10 million switching cycles, the Shutter D23 is designed for reliable continuous operation.

Request for a quote

Germany

Verified by Europages

Pneumatic timers are used for the precise time control of pneumatic signals in pneumatic circuits or systems. The pressure-independent function of time delay starts when pressure is applied to the control port. After the pre-selected time is elapsed, an internal 3/2 way valve is switched. The pneumatic timer is reset to the initial condition if the control port is vented for at least 300 ms. The adjustable time delay depends on the chosen version and amounts between 0.5 and 180 s. Due to its design the control pressure level must not be below working pressure level. As a result of the fire-risk evaluation according to EN 13463-1, the pneumatic timers are not subject to ATEX regulations. This means they may also be used in explosion hazardous areas as defined in IIG/ IID.

Request for a quote

Germany

Verified by Europages

Pneumatic timers are used for the precise time control of pneumatic signals in pneumatic circuits or systems. The pressure-independent function of time delay starts when pressure is applied to the control port. After the pre-selected time is elapsed, an internal 3/2 way valve is switched. The pneumatic timer is reset to the initial condition if the control port is vented for at least 300 ms. The adjustable time delay depends on the chosen version and amounts between 0.5 and 180 s. Due to its design the control pressure level must not be below working pressure level. As a result of the fire-risk evaluation according to EN 13463-1, the pneumatic timers are not subject to ATEX regulations. This means they may also be used in explosion hazardous areas as defined in IIG/ IID.

Request for a quote

Do you sell or make similar products?

Sign up to europages and have your products listed

Add my business
Filters

Results for

Signalling systems - Import export

Number of results

3 Products