• europages
  • >
  • COMPANIES - SUPPLIERS - SERVICE PROVIDERS
  • >
  • ied protection

Results for

Ied protection - Import export

Germany

Germany

Verified by Europages

• Face shield to protect against class 2 arcing faults (7 kA / 423kJ/m²) • Tested in accordance with DIN EN166, as well as the GS-ET-29 test principle and is VDE-approved • The visor is manufactured from 2,0mm-thick green Polycarbonate • It has excellent optical qualities, and its light transmittance VLT (D65) according to ISO 10527:2007 i ≥75% • For better protection of the ears, the visor is extended toward the back • The visor can be folded up and can be locked in place in any position by means of a screw connection • For protection against heat entering through the bottom edge of the shield, the visor has a chin protection with a Nomex bib

Request for a quote

Germany

Verified by Europages

• Face shield to protect against class 2 arcing faults (7 kA / 423kJ/m²) • Tested in accordance with DIN EN166, as well as the GS-ET-29 test principle and is VDE-approved • The visor is manufactured from 2,0mm-thick Polycarbonate • It has excellent optical qualities, and its light transmittance VLT (D65) according to ISO 10527:2007 i ≥75% • For better protection of the ears, the visor is extended toward the back • The visor can be folded up and can be locked in place in any position by means of a screw connection • For protection against heat entering through the bottom edge of the shield, the visor has a chin protection with a Nomex bib

Request for a quote

Germany

Verified by Europages

Discover precision, quality and maximum freedom in planning: With its stainless steel frame and the high IP65 protection the CWL-I is perfectly suitable for demanding industrial requirements. This verifiable checkweigher or catchweigher reliably provides precise results at high loads. Realize the optimal solution for your needs with a large model variety and numerous options. Easily integrate the CWL-I in your internal conveyor system whether it is a sorting application, infeed line or a shipping system. Efficiently configure and parameterize your solution with the included Bizerba Configuration Tool software.

Request for a quote

Germany

Verified by Europages

The reinforced version of the type 8037 sliding gate motor valve is suitable for use in potentially explosive atmospheres in accordance with Directive 94/9EG. Media such as steam, liquids, gases etc. can be excellently controlled with this motor valve, even in hazardous areas. Metal bellows Position electronics Analog stroke feedback Limit switch . . . Ex zones 1, 2, 21 and 22 Protection class I 2G Ex de (ia) IIC T6/T5 or T4 (gas version) Protection class II 2D Ex tD (iaD) A21 IP 66 T80C (dust version)

Request for a quote

Germany

Verified by Europages

The sliding gate motor valve type 8037 is suitable for the intended use in potentially explosive atmospheres according to Directive 94/9EG. Media such as steam, liquids, gases etc. can excellently be controlled with this motor valve, even in hazardous areas. Metal bellows Position electronics Analog stroke feedback Limit switch . . .Ex zones 1, 2, 21 and 22 Protection class I 2G Ex de (ia) IIC T6/T5 or T4 (gas version) Protection class II 2D Ex tD (iaD) A21 IP 66 T80C (dust version)

Request for a quote

Do you sell or make similar products?

Sign up to europages and have your products listed

Add my business

Germany

The workplace-system luminaire WLA illustrates just what flexibility looks like. Versions in four different lengths provide individual lighting for any table width in a wide range of industrial applications. To minimise installation work even at daisy-chained workplaces, the concept enables multiple luminaires to be through-wired. — LED technology — Colour temperature neutral white 5000 K — Colour rendering Ra > 80 — Glare-free thanks to structured cover — Housing made of colourless anodised aluminium and grey plastic — PC screen — Mounting by means of T-slots (8 mm) or luminaire bracket (accessories) — Switch for On/Off — Degree of protection IP20, protection class I — Supplied with built-in Wieland GST18i3 connector / socket (luminaires with through-wiring) — Accessories: Cables, Luminaire bracket sets

Request for a quote

Germany

The adjustable ALD arm-mounted luminaire appeals for its flexible head joint and balanced arm. The wide area of illumination of the work area and option of continuous dimming ensure ergonomic working, even for activities that take a long time. Plus the ALD is suitable for use in all kinds of industrial environments. — LED technology — Colour temperature neutral white 5000 K — Colour rendering Ra > 80 — Glare-free thanks to structured cover — Housing made of colourless anodised aluminium and grey plastic — Polycarbonate plastic screen — Ergonomic arm-mounting technology with 3D head joint — Touch panel in luminaire head for On / Off and dimming — Degree of protection IP20; protection class I — Supplied with approx. 3 m connecting cable and plug-in power supply with plug type CEE 7/16 (Europlug), BS 1363 and NEMA 1-15P — Various fasteners as accessories

Request for a quote

Germany

This high-quality stainless steel cap can be used to hide an ABS-Lock I+II system sleeve that is permanently installed in the subsurface. Not only does it look great - it also protects the sleeve from dust and other contamination. The cap closes automatically, if it is installed on a wall. Protective cap for our ABS-Lock II model High-quality stainless steel material Ø 40mm Closes automatically, if installed on a wall

Request for a quote

Germany

Additional information•Output voltage: 24 V •Protection Class: I •Current: 18750 mA •Spec.0 cover sheet FW-Type: OF450-24 •Input voltage: 100-240 V •MTBF: 200.000h acc. Mil217F (based on calculations at 120Vac/60Hz & 230Vac/50Hz, ambient 25°C and 100% load) (The MTBF are theoretically determined values, which does not guarantee the lifetime of the product or of the electrolytic ) h •Input tolerance: +10% / -10% •Storage temperature : -40°C - 70°C •Input current: 5500 mA •Working temperature: 0°C - 70°C •Humidity: 5% to 95% •Frequency: 50 / 60 Hz •AC Input: Screw Terminal •DC output: Screw Terminal •Family : OF450 •Output voltage tolerance: +2% / -2% •Means of Protection: Input Output 2xMOPP, Input - Ground 1xMOPP •Output voltage 2: 5 V •current 2: 100 mA •Standard: IEC60601-1, IEC62368-1

Request for a quote

Germany

Universal input 100 to 240 V AC, constant voltage, current limited, low standby power, High efficiency, continuously short circuit proof, Leakage current ≤ 100 μA, small package, without active fan. Additional information •Protection Class: I •MTBF: 200.000h acc. Mil217F (based on calculations at 120Vac/60Hz & 230Vac/50Hz, ambient 25°C and 100% load) (The MTBF are theoretically determined values, which does not guarantee the lifetime of the product or of the electrolytic ) h •Input voltage: 100-240 V •Storage temperature : -40°C - 70°C •Input tolerance: +10% / -10% •Working temperature: 0°C - 80°C •Humidity: 5% to 95% •Standard: IEC60601-1 •Frequency: 50 / 60 Hz •Family : OF65 •AC Input: flat pin connector •Output voltage tolerance: +2% / -2%

Request for a quote

Germany

Technical problems and new ideas are the inspiration of our engineers while creating the solution for your substation to fulfill the project requirements. The broad expertise in different protection and control vendors and the excellent collaboration with our partners we deliver solutions for your substation. Our expertise in engineering lies within: Parameterization and configuration of IEDs SCADA modeling and integration with protocols IEC 60870-5, DNP3, Modbus etc. SAS/SCS modeling and integration via IEC 61850. SCL-files modeling. You find a detailed view of our expertise on our website:

Request for a quote

Germany

The last steps in a project can be very stressful. We relief you from the stress by ensuring that all project requirements are fulfilled before putting your substation into operation. Factory Acceptance Test or Site Acceptance Test are important milestones in a project cycle that we can execute for you. Technical equipment or systems that we take into operation: IEDs (Protection and Control). SCADA and Substation Automation Systems (SCS, SAS). End-to-End communication to control centers (CC). You find a detailed view of our expertise on our website:

Request for a quote

Germany

Power Management Controller for power supply and system protection Can be used as an independent system or as an extension to a NORISYS 4 automation platform Option for connecting a colour touch panel as HMI and visualisation USB port for configuration and service RS-485 for NORISYS 4 ExtBus communication Generator set control with automatic start/stop function Parallel and isolated operation Automatic synchronisation Generator protection functions, 3-phase Power supply protection function, 3-phase Approvals pending: BV, DNV, GL, LR

Request for a quote