GermanyHannover and Lower SaxonyManufacturer/producer

Germany

The temperature transmitter PA2530 with mit IO-Link is suitable for hygienic temperature measurement in connection with the following resistance thermometers ■ LABOM MiniTherm, Type series GA27 (see data sheet T4-014, T4-015 and T4-017) ■ LABOM Clamp-on, Type series GA2610 (see data sheet T4-028) Due to its compact design the transmitter fulfils the hygienic requirements of plant and machinery engineering.

Request for a quote

Germany

Features ■ Differential pressure transmitter with metallic diaphragm ■ Function modules: Multifunctional display; Switching module with 2 floating channels; HART® module ■ Function module replacement on site without recalibration, „plug and measure“ ■ Nominal ranges 0.4 up to 40 bar ■ Turndown 5:1 ■ Accuracy ≤ 0,15 % ■ Output signal: 4…20 mA; alternative with PROFIBUS PA ■ Output functions: linear, invers, table function ■ Stainless steel case in sturdy design, degree of protection IP 69K ■ Media temperature -40...100 °C ■ Wetted parts stainless steel ■ EAC declaration (upon request) Options ■ Approvals/Certificates - Explosion protection for gases and dust - Certificate of measuring equipment for Russian Federation - Material certificate and calibration certificate as per EN 10204-3.1 - Classification per SIL2

Request for a quote

Germany

Features ■ Pressure transmitter for the measuring of relative and absolute pressures of gases, vapors and liquids ■ Stainless steel case in sturdy design, degree of protection IP 65/67 ■ Accuracy 0.1 % ■ High-resolution graphic display with Intuitive 4-button operation and backlight ■ Comprehensive parameterising and simulation and diagnostic functions ■ Nominal range 0.25 bar to 400 bar ■ Turndown up to 100:1 ■ Measuring rate up to 100 Hz ■ Output signal 4…20 mA with HART® protocol ■ Digital communication via PDM, FDT/DTM, 375/475 Field Communicator ■ Output functions: linear, invers, square root, table function ■ Media temperature -40…100 °C ■ Wetted parts stainless steel ■ Case design: process connection bottom or back ■ Process connections: various screw-in thread with internal diaphragm ■ Approved according to NAMUR 95 Options ■ Explosion protection; SIL2; material certificate and calibration certificate per EN 10204 ■ Degree of protection IP 69K

Request for a quote

Germany

Features ■ Digital pressure transmitter with IO-Link V1.1 output signal ■ Data transmission rate COM 3 (230.4 kBaud) ■ Hygienic design as per EHEDG recommendation ■ Accuracy ≤ 0.3 % ■ Case and wetted parts of stainless steel, degree of protection IP 65 ■ Nominal range -400…400 mbar up to -1…100 bar ■ 2 switching outputs maximum Additional features ■ Approvals/Certificates - Material certificate per EN 10204 - Calibration certificate per EN 10204 - Roughness height rating with inspection certificate acc. to EN 10204-3.1 ■ Hygienic design ■ Wetted parts electropolished Application The pressure transmitter COMPACT with IO-Link is suited for measuring the relative pressure of gases, vapors and liquids. Due to the case design as per EHEDG recommendation and various process connections, the transmitter is suitable for the hygienic requirements of plant and machinery engineering.

Request for a quote

Germany

The resistance thermometer is suited for operation on tanks and pipings especially in hygienic applications. All standard types of process connections are available. Because of its robust design it is suitable for use in a great number of technological processes. The change in resistance, dependant on the measurement temperature, can be detected by a transmitter and converted into a standardized signal. A variety of transmitters for head mounting is available for different applications. For In-process calibration the integration of a special measuriung insert with additional test pipe is possible (data sheet T4-025-45,Type GA3100, reference sensor: data sheet T4-025-46, Type GA3110).

Request for a quote

Germany

Maintain the high accuracy of your BlowerDoor measuring technology by regularly submitting it to a calibration. Benefit from the high accuracy of the BlowerDoor measuring technology: At ± 4% or rather ± 5% (flow rings D + E), the accuracy of the BlowerDoor testing flow rings – as well as that of the pressure gauge DG-700 (± 1%) or DG-1000 (± 0.9 %) – clearly exceed the minimum legal requirements. The manufacturer’s calibration as well as the calibration with DAkkS-certificate, are subject to the highest quality standards. When calibrated, all measuring systems undergo a preceding functional test. If required, we will gladly provide you with a replacement device at favorable rates and conditions, while your BlowerDoor measuring system is being calibrated or repaired.