• europages
  • >
  • COMPANIES - SUPPLIERS - SERVICE PROVIDERS
  • >
  • gas on

Results for

Gas on - Import export

GermanyHannover and Lower Saxony

Germany

Verified by Europages

The AWALIFT 1/2 is used primarily in municipal applications for draining large properties. It is a fully automated, floodable sewage pumping system with a proven separator system for up to 750 EW. Alternating two pumps provides a high level of operational reliability. There is no need to provide reserve pumps. This system also has a gas and odor-tight tank, the surface of which is coated with high-quality corrosion protection. •Larger buildings, industrial companies, individual streets •Facilities that cannot be drained using natural gradient •As protection from backwater damage •Infrastructure facilities such as airports, industrial parks, subway systems etc. Product features One tank with two separator systems Two rotary pumps and motors according to type and operating location required Two non-return valves AWASTOP DN 100 K Y-pipe DN 100 Two pressure pipe gate valves DN 100 Level measurement LGA certified according to DIN EN 12050-1 /. -4

Request for a quote

Germany

Verified by Europages

Electrical gas heaters for operating pressure up to 500 bar - Seal gas heaters, fuel gas heaters - Natural gas heaters for gas pressure regulation stations - LNG and LPG vaporizers - Vaporizers and heaters for industrial gases - Process heaters - Gas heaters for analysis and laboratory application ATEX, IECEx, TR-CU and other international certificates

Request for a quote

Germany

Fire safety is one of the areas where the use of BlowerDoor measurements is increasingly gaining in importance. In general, it is server rooms that are measured, where in the case of fire, this is quenched by special extinction gases. High-quality technology can thus be protected against damage from sprinkling or fire water. A prerequisite for the fire protection through extinction gases is an airtight room envelope.With the Minneapolis BlowerDoor measuring system and the FireProtection software, you can easily and accurately determine extinction gas holding times in accordance with ISO 14520 in rooms of angular volume.

Request for a quote

Germany

Installation into pipelines as inline detonation flame arrester e. g. for the protection of ignition gas lines or measuring devices. Applicable for all materials of the explosion groups IIA1 up to IIA with a maximum experimental safe gap (MESG) > 0.9 mm. Operating from both sides, for a maximum operating pressure of 1.2 bar abs. and a maximum operating temperature of 60 °C.

Request for a quote

Germany

For installation into pipes to protect containers and components against stable detonation of flammable liquids and gases. Tested and approved as detonation flame arrester type 4. Approved for all substances of explosion groups IIA1 to IIA with a maximum experimental safe gap (MESG) > 0.9 mm. Working unidirectional in pipes, whereby an operating pressure of 1.2 bar abs. and an maximum operating temperature of 60 °C must not be exceeded. Provided with one temperature sensor (PT 100) the armature is certified against short time burning from one side. The installation is not dependent on the position and both directions of flow are possible. During installation, please observe the direction of detonation and the indication „protected side“.

Request for a quote

Do you sell or make similar products?

Sign up to europages and have your products listed

Add my business

Germany

For installation into pipes to the protection of vessels and components against stable detonation of flammable liquids and gases. Tested and approved as detonation flame arrester type 4. Approved for all substances of explosion groups IIA1 to IIA with a maximum experimental safe gap (MESG) > 0.9 mm. Bi-directionally working in pipes, whereby an operating pressure of 1.2 bar abs. and an operating temperature of 60 °C must not be exceeded. All sizes are tested against “stabilized burning” and withstand this up to a max. burn time BT ≤ 30.0 min. To detect a “stabilized burning” a temperature sensor must be installed at each endangered side. Mounting is acceptable in any position, in horizontal as well as in vertical pipes.

Request for a quote

Germany

Application as inline armature with venting and breather valve function for vessels, used preferably for installations in pipes. The exhaust air is carried away via a pipe. The ventilation is also effected via a pipe, which is preferably used to carry inert gas. Functions the same as KITO® VD/o3-… (type sheet F 18 N).

Request for a quote

Germany

Gas expansion thermometer NS 100/160, various process connections Features High quality case with bajonet ring NS 100/160, degree of protection IP 66 Nominal ranges -40 °C…700 °C, further nominal ranges from -200 °C...700 °C upon request Case and wetted parts of stainless steel Different connections can be supplied Temperature detecting element 6, 8 and ≥ 10 mm diameter Short immersion lengths of the temperature detecting element may be used Accuracy class 1 as per EN 13190 Micro adjusting pointer for indication correction EAC declaration (upon request) Options Explosion protection (ATEX) for mechanical devices Certificate of measuring equipment for Russian Federation Calibration certificate as per EN 10204 Case with liquid filling Electronical angle-of-rotation sensor, Type series PL1100, see data sheet D6-020 Connection to zone 0 with thermowells (upon request)

Request for a quote

Germany

These thermometers are suitable for use outdoors and in aggressive environments. The devices can also be supplied with additional liquid damping for use in extreme conditions. Further information on mounting see operating instructions. ■ Case, measuring system and wetted parts of stainless steel ■ Case NS 100/160, degree of protection IP 66 ■ Stem diameter 6, 8 and ≥ 10 mm ■ Short immersion lengths of the stem may be used ■ Accuracy class 1 or 2 per DIN 16196, depending on range ■ Micro adjustment pointer for indication correction ■ Switch functions (electrical contact device) per DIN 16196:

Request for a quote