• europages
  • >
  • COMPANIES - SUPPLIERS - SERVICE PROVIDERS
  • >
  • electrode sensor

Results for

Electrode sensor - Import export

Germany

Germany

Verified by Europages

Smart embroidery is one of the most well-known technologies to add functions to and integrate them in textiles. Thus, we produce intelligent textiles with our special CNC wire laying technology. Potential applications include: > textile-based electrodes > flexible antennas > textile sensors > medical devices reliant on electromagnetic coils

Request for a quote

Germany

Verified by Europages

Areas of Application and Advantages BEDIA CLS 10 stands for special versions of our well-proven CLS 40 series for heavy duty applications. Currently, the BEDIA CLS 10 series includes a variety of sensors, which are compatible replacement parts for level switches from Cooper Standard and Robert Shaw which are obsolete nowadays – and this in well proven BEDIA quality. This also includes sensors with 2 complementary CMOS outputs. It should be emphasized that the water sensors with two complementary outputs can be operated with a supply voltage of 4.75 V DC – 32 V DC. Operating Principle The function of the sensor is based on the capacitive principle. It detects the change in capacitance that arises when an electrode surrounded by air is immersed into a liquid medium. This change in capacitance at the electrode of the sensor excites an oscillator, causing it to oscillate (at a frequency of approx. 600 kHz). Then this signal is processed by a microprocessor-based evaluation circuit.

Request for a quote

Germany

Verified by Europages

BEDIA level monitoring sensors are used to monitor the filling levels of liquids. The sensors detect when a filling level is exceeded or falls below a limit. Water-based liquids like coolants, AdBlue®, fresh water, waste water and oil-based liquids like motor oils, hydraulic oils, fuels and brake fluids can be monitored. Operating Principle The function of the sensor is based on the capacitive principle. It detects the change in capacitance that occurs when an electrode surrounded by air is immersed into a liquid medium. This change in capacitance at the electrode of the sensor excites an oscillator. This signal is processed by a microcontroller-based evaluation circuit which activates or deactivates an output stage. Types of Media The level monitoring sensors are designed for two different media types: For electrically conductive liquid media with relative permittivity within a range of εr 35 … 85 (water, coolant, water/glycol mixture) For electrically non-conductive liquid media

Request for a quote

Germany

Verified by Europages

BEDIA level monitoring sensors are used to monitor the filling levels of liquids. The sensors detect when a filling level is exceeded or falls below a limit. Water-based liquids like coolants, AdBlue®, fresh water, waste water, bilge water and oil-based liquids like motor oils, hydraulic oils, fuels and brake fluids can be monitored. Since they contain no mechanical moving parts, their function will not be influenced by dirt particles or other influences. No electrical current is sent through the medium via an electrode with BEDIA sensors, an electrolysis of the medium is not possible. Operating Principle The function of the sensor is based on the capacitive principle. It detects the change in capacitance that occurs when an electrode surrounded by air is immersed into a liquid medium. This change in capacitance at the electrode of the sensor excites an oscillator. This signal is processed by a microcontroller-based evaluation circuit which activates or deactivates an output stage.

Request for a quote

Germany

Verified by Europages

BEDIA level monitoring sensors are used to monitor the filling levels of liquids. The sensors react when a filling level is exceeded or falls below a limit. Aqueous mediums like coolants, AdBlue®, fresh water, waste water, bilge water and oil-based liquids like motor oils, hydraulic oils, fuels and brake fluids can be monitored. Since they contain no mechanical moving parts, their function will not be influenced by dirt particles or other influences. No electrical current is sent through the medium via an electrode with BEDIA sensors, an electrolysis of the medium is not possible. Operating Principle The function of the sensor is based on the capacitive principle. It detects the change in capacitance that arises when an electrode surrounded by air is immersed into a liquid medium. This change in capacitance at the electrode of the sensor excites an oscillator, causing it to oscillate. Then this signal is processed by a microprocessor-based evaluation circuit.

Request for a quote

Do you sell or make similar products?

Sign up to europages and have your products listed

Add my business

Germany

KHM 102 PROFESSIONAL Smallest unit of measure: +/- 0,5 % Temperature compensation: automatic or by way of external sensor from -50 to + 95° C by way of internal sensor from 0 to 60° C Permissible surrounding temperature: 0 to 60° C Permissible surrounding humidity: 0 to 80% (non-condensing) Electricity supply: 9 V block battery (type: JEC 6F"") included in scope of supplies battery EOL indicator: automatic, “BAT” when battery is empty KHM 102 PROFESSIONAL S91 digital moisture measuring unit with automatic temperature compensation (ATC), battery, measuring cable, temperature hand sensor, hollow hammer electrode with steel pins, ready to operate with measuring tables for wood in the carrying case.

Request for a quote

Germany

KHM 101 JUNIOR Smallest unit of measure: +/- 0,5 % Temperature compensation: automatic or by way of external sensor from -50 to + 95° C by way of internal sensor from 0 to 60° C Permissible surrounding temperature: 0 to 60° C Permissible surrounding humidity: 0 to 80% (non-condensing) Electricity supply: 9 V block battery (type: JEC 6F"") included in scope of supplies battery EOL indicator: automatic, “BAT” when battery is empty KHM 101 JUNIOR S91 digital moisture measuring unit with automatic temperature compensation (ATC), battery, measuring cable, temperature hand sensor, shock electrode with steel pins, ready to operate with measuring tables for wood in the carrying case.

Request for a quote

Germany

KHM 104 BAHO Smallest unit of measure: +/- 0,5 % Temperature compensation: automatic or by way of external sensor from -50 to + 95° C by way of internal sensor from 0 to 60° C Permissible surrounding temperature: 0 to 60° C Permissible surrounding humidity: 0 to 80% (non-condensing) Electricity supply: 9 V block battery (type: JEC 6F"") included in scope of supplies battery EOL indicator: automatic, “BAT” when battery is empty KHM 104 BAHO (BUILDING MATERIALS / WOOD) as in the PROFESSIONAL carrying case S91 digital moisture measuring unit with automatic temperature compensation (ATC), battery, measuring cable, temperature hand sensor, hollow hammer electrode with steel pins, ready to operate with measuring tables for wood and building materials, 100 mm brush probe, conductive paste and red building material plug.

Request for a quote

Germany

KHM 103 EXPERT Smallest unit of measure: +/- 0,5 % Temperature compensation: automatic or by way of external sensor from -50 to + 95° C by way of internal sensor from 0 to 60° C Permissible surrounding temperature: 0 to 60° C Permissible surrounding humidity: 0 to 80% (non-condensing) Electricity supply: 9 V block battery (type: JEC 6F"") included in scope of supplies battery EOL indicator: automatic, “BAT” when battery is empty KHM 103 EXPERT S91 digital moisture measuring unit with automatic temperature compensation (ATC) and M100B precision space and temperature measuring unit, batteries, measuring cable, temperature hand sensor, shock electrode with steel pins, brush probe, special board sensor, conductive paste, building material plug complete with measuring tables for wood and building materials in the carrying case.

Request for a quote