Results for
EPP ENERGY PEAK POWER GMBH
Germany
Necessary accessories for the Varta Split Core current transformer for connection.
Request for a quoteEPP ENERGY PEAK POWER GMBH
Germany
With an additional current transformer, the production data of the inverter can be recorded and visualized in the VARTA monitoring portal. As a result, you do not need a Solar-Log data logger to integrate the inverters.
Request for a quoteEPP ENERGY PEAK POWER GMBH
Germany
The MultiPlus-II combines the functions of the MultiPlus and the MultiGrid. It has all the functions of the MultiPlus and also has the option of an external current transformer in order to implement the PowerControl and PowerAssist functions or to optimize self-consumption with external current measurement.
Request for a quoteE. DOLD & SÖHNE GMBH & CO. KG
Germany
• According to IEC/EN 62 020 • for AC and pulsating DC currants Type A to IEC/TR 60755 • 9 tripping values from 10 mA to 10 A or from 10 mA ... 30 A • Frequency range 20 ... 2000 Hz • Selection of manual or automatic reset • With prewarning • With test and reset button • Broken wire detection • Short reaction time • With adjustable delay tv • De-energized on trip • LED indication for auxiliary supply and state of contact • 2 x 1 changeover contact • With sealable cover • Devices available in 3 enclosure versions: IR 5882: 63 mm deep with terminals near to the bottom to be mounted in consumer units or industrial distribution systems according to DIN 43 88 - width 105 mm - with internal residual current transformer
Request for a quoteE. DOLD & SÖHNE GMBH & CO. KG
Germany
• According to IEC/EN 62 020 • for AC and pulsating DC currants Type A to IEC/TR 60755 • 9 tripping values from 10 mA to 10 A or from 10 mA ... 30 A • Frequency range 20 ... 2000 Hz • Selection of manual or automatic reset • With prewarning • With test and reset button • Broken wire detection • Short reaction time • With adjustable delay tv • De-energized on trip • LED indication for auxiliary supply and state of contact • 2 x 1 changeover contact • With sealable cover • Devices available in 3 enclosure versions: IL 5882: 63 mm deep with terminals near to the bottom to be mounted in consumer units or industrial distribution systems according to DIN 43 880 - width 35 mm - for connection of external residual current transformer, e. g. DOLD ND 5016, ND5019
Request for a quoteE. DOLD & SÖHNE GMBH & CO. KG
Germany
• According to IEC/EN 62 020 • for AC and pulsating DC currants Type A to IEC/TR 60755 • 9 tripping values from 10 mA to 10 A or from 10 mA ... 30 A • Frequency range 20 ... 2000 Hz • Selection of manual or automatic reset • With prewarning • With test and reset button • Broken wire detection • Short reaction time • With adjustable delay tv • De-energized on trip • LED indication for auxiliary supply and state of contact • 2 x 1 changeover contact • With sealable cover • Devices available in 3 enclosure versions: SL 5882: 100 mm deep with terminals near to the top to be mounted in cabinets with mounting plate and cable ducts - width 35 mm - for connection of external residual current transformer, e. g. DOLD ND 5016, ND5019
Request for a quoteDo you sell or make similar products?
Sign up to europages and have your products listed
Results for
Current transformers - Import exportNumber of results
6 ProductsCompany type