The precision RTD simulator is used where measuring instruments or controlling means with high precision must be examined or calibrated. The simulator is suitable for calibration laboratory and service centers which need a computer-controlled resistance decade for the automation of calibration procedures. All standard platinum and nickel RTD can be simulated with very high accuracy according to scales ITS 90 or IPTS 68. Temperature regulators, transducers etc. often supply a pulsed signal current in order to reduce the self-heating of the RTD. Devices with electronic simulation of RTD are therefore inclined to swinging and do not function with this application. Features: — Simulation of Pt100, Pt200, Pt500, Pt1000, Ni100 and Ni1000 sensors — Accuracy 0.02 °C — Temperature scales ITS 90, IPTS 68 — Real Ohm simulation — Control manually or remotely via RS232/IEEE488/USB Converter

Request for a quote

Germany

Verified by Europages

The precision calibration unit combines high accuracy, low drift, low noise and superior long-term stability with multiple functionality and simple operation. Ramps, Δ+/Δ-, and multiple setpoint storage make the operation of the device easier for the user. For that reason the application possibilities are many: — Calibration of current and DC-voltage meters — Precise testing of thermocouple temperature measuring instruments — Calibration of controllers, sensors, detection devices and other devices used in process control — Open-loop process control with the aid of integrated ramp function Features: — High precision current and voltage source ± 52 mA, ± 30 V — Option: ± 22 mA, ± 60 V — Precision simulation for all conventional thermocouple types (optional) — Error limit 0.003 % Rdg. — Standard with RS232 and IEEE488 interface, USB and Ethernet (optional) — Current "SINK"

Request for a quote

Germany

Verified by Europages

The DIGISTANT® model 4420 universal calibrator, built to use in the field, is ideal for checking and calibrating temperature measurement and control devices. The versatile functions of this portable unit allow to be used on-site or at a fixed location, on the test floor or in the laboratory. The unit allows the simulation and measurement of voltages, currents, temperatures and resistances.Simultaneous transmission and measurement allow, for example, controllers to be checked precisely. The automatic ramp function is used for controlling processes. The universal calibrator measures and simulates 14 models of thermocouples and Pt100. Features: Calibration and measurement unit for voltages, currents, temperatures and resistances All functions can be fully controlled and configured via RS232 interface Simultaneous transmission and measurement Automatic ramp function Simple menu assistance via display Voltage range ± 1 μV to ± 11.000 V Current range ± 200 nA to ± 22.000 mA

Request for a quote

Germany

Verified by Europages

Wherever temperatures are measured, temperatures must also be simulated. The Pt100-simulator is suitable for a wide area of applications. It has a wide range of simulation, which is resolved in 0.1 °C steps and makes many assignments in chemistry-, measuring-, controlling-, medicine and household applications, food industry, vehicle construction, air- and space travel and power plants easy to solve. Often in the past several simulators had to be used alongside to achieve either resolution or the range of the relevant application. As an extra advantage to the user temperatures can be entered in degrees celsius. Additional extensive conversions and readings in tabulation sheets are no longer necessary. Features: — Simulation range -100 °C up to +500 °C — Resolution 0.1 °C — Calibration in accordance to DIN EN 60751 — Simulation of line resistance 10 Ω, 20 Ω or 30 Ω — Sturdy aluminium-housing

Request for a quote

Germany

Verified by Europages

The force measuring chain is an universal reference measuring chain for the calibration of press-fit force measuring equipment. It finds applications in the quality assurance, commissioning and equipment monitoring fields. A DAkks calibration certificate is included so that the force measuring chain can be traced back. The calibration is traceable through accreditation at the German Accreditation Body. The calibration certificate records the displayed values for mounting positions at 0°, 120° and 240°. During calibration in field, the reference load cell is inserted in line with the flux of the press-fit measuring equipment. The force application is of central significance here for the quality of the measurement. Special force application parts are required, so that the line of action of the force agrees as exactly as possible with the geometrical axis of the load cell that is to be measured (central loading).

Request for a quote

Germany

Verified by Europages

The multipurpose digital indicator TRANS CAL 7281 can be used wherever there is a need to perform high-precision, in-situ calibrations of sensing components used in equipment such as presses, torque tools or pressure-regulating systems. An optional factory calibration certificate or German-accredited DKD/DAkkS calibration certificate can be provided when the measurement device needs to be used as a reference. This provides a quick and cost-effective way of assessing a system with traceable documentation of measurement results. If a reference measurement cannot be made because the sensor location is difficult to access, it is still possible to test the zero point, the input, output and isolation resistance as well as the calibrating offset of the fitted sensor. It is also possible to check the indicating device by measuring the excitation voltage and simulating the characteristic values (mV/V or V) of the sensor used.

Request for a quote

Germany

Verified by Europages

High-precision angle measuring system with +/-0.1s accuracy for measuring and calibration applications. The signal sampling is done by an interferometric operating principle (laserscale) The graduation period is 1µm, the generated signal period of the output signal is 250nm. Scale errors are self-compensated by using six reading heads in a special arrangement. The measured values can be output in csv format via the USB interface. The software for measured value acquisition and storage is included in the scope of delivery.

Request for a quote

Germany

Verified by Europages

Essential for direct reading and high-capacity torque wrench calibration! Mechanical loaders increase the accuracy ot torque test results while simultaneously reducing technician fatigue from pulling or pushing on torque wrenches during testing. A mechanical loader is the perfect accessory to increase the repeatability and productivity of the System 5 Digital Torque Tester. The drive system for each loader assures true 90-degree force application to eliminate force angle error in testing. In addition, the loaders mechanical advantage reduces technician effort and fatigue, particularly in high-capacity tool testing. SR Mechanical Loaders use the highest quality ball screws to assure smooth operation and extended service life. Welded steel frames and rigid transducer mounting plates assure torque load is properly resisted. Optimized gearing selection reduces physical effort to operate, enhancing productivity and ergonomic safety.

Request for a quote

Germany

Verified by Europages

Digital torque wrench tester with manual loader. Ideal for torque wrench calibration and adjustment. Pole holder and plate are equipped on all models, which helps keep wrenches in optimal testing position. Peak/Run modes with 10 customizable hi/lo judgment patterns. Colour Judgement Display makes it easy to confirm readings are within your set parameters. Up to 1000 measurement data items can be stored in the memory. Global units of measure selection by keypad: cNm, NM, kgf.cm, kgf.m, lbf.in, lbf.ft. Sample quantity, maximum value (Hi), minimum value (Lo) and mean value can be displayed. Includes Calibration Certificate: ILAC MRA. CE markings applied for use in the EU. [...]

Request for a quote

Germany

Verified by Europages

OMS Lite is our NEW and intuitive torque management software package, in a more compact and easy-to-use format. OMS Lite offers a new and updated interface, following our recognisable and user-friendly icon-based navigation system for faster speed of use, ideal for production process and quality verification as well as assembly tool auditing. The torque software is also quick and easy to install and simple to configure for users, making it our most efficient and uncomplicated torque software package to date. Used in conjunction with Crane’s existing portfolio of torque measurement products, OMS Lite is able to provide the perfect quality system for periodic sampling of both residual and dynamic torque and angle measurements. With features such as ‘Jobs’, ‘Rounds’, torque traces and reports, it’s the ideal software system to manage all of your critical assembly tool and quality audit data, in one place. [...]

Request for a quote

Germany

Verified by Europages

The Perfect Database for the Control of Torque Tool Calibration Torque Tool Manager 4.0 software is calibration and certification specifically designed to work with System 8® and Torq-Tronics 2® Digital Torque Testers! It will fulfill your TS 16949 and ISO calibration certificate requirements far more cost-effectively than manual record keeping systems! Torque tool calibration requires attention to detail in every respect, and maintenance of records pertinent to all factors - as well as creating certificates of calibration for each calibrated item. When all of this can be automated the process becomes more efficient, less prone to error, and less costly to operate. Torque Tool Manager, used with SR digital torque testers, improves control and efficiency for almost all of the operations. Specifications and tester settings are stored in the software and downloaded to the tester exactly when needed. The technician is guided and supported by the software during the testing, and...

Request for a quote

Germany

Verified by Europages

This high-precision calibration source is able to measure currents up to ±50 mA, voltages ±100 V and temperature setpoint values of 12 thermocouple types, including R, S, B, J, T, E, K and N. Voltage drops across the measuring leads can be easily compensated via the sense line. With “thermoelectric voltage simulation” you can enter °C, °F and K, the temperature scales ITS-90 or IPTS-68 and the reference junction type constant/external. Furthermore, when simulating thermocouples a calibrated external reference junction can be used, with the calibration data being taken into account in the device. The device can be operated both via the keypad and via the Ethernet and USB interface. Features: — DC voltage up to ±100.0000 V, ±0.002 % — DC current up to ±50.0000 mA, ±0.005 % - Thermocouple simulation of R, S, B, J, T, E, K, N, M, C, D, G2 - Automatic sequence function (ramp function)

Request for a quote

Germany

Verified by Europages

The precision Pt100 simulator is used wherever measuring instruments or controlling systems have to be tested or calibrated with great precision. The standard version model 4506 simulates 24 set temperature values. Totally different temperature ranges are required in the case of special applications, such as in the food industry, the medical science etc. Model 4506 S is recommended for these applications and can be fitted with 24 temperature values according to customer specifications. A distinctive feature of these simulators is their simple operation. The resistance values required for simulation are directly set in °C. There is no need to use loof-up tables. Today in many cases a certificate is needed more than ever force measurements. This certificate is available under order code 45DKD-.. . Features: 24 set temperature values Calibration per DIN EN 60751 Resistor material: MANGANIN®, TK ≤ 10 ppm/K Pt100, Pt500, Pt1000 Available with DKD Certificate if required

Request for a quote

Germany

Over the last few years, we at EP-E have designed and introduced a series of primary standards for gases, designed for use in calibration laboratories. As a technology partner of the Physikalisch-Technische Bundesanstalt (PTB) in Braunschweig, our solutions are based on the highest standards. The EP gas bell plungers generate a volume flow which is traceable to the SI units length and time. The pistons are driven by a stepper motor via a spindle. In the initial state one piston is fully retracted and the other fully extended. The volume flow can be set with high precision via the piston cross section and the travel speed. At the end of the calibration process, both pistons are in the opposite position to the initial position. The calibration device is preferably operated with air, which can be supplied with up to 6 bar. The EP gas bell pistons convince by highest measuring accuracy up to 0.15% (k=2).

Request for a quote

Germany

The EP endurance test benches are used to test various components over a defined cycle for durability, e.g. temperature and pressure cycle tests. A high series quality requires precision and reliability. Operational and endurance tests are necessary in order to be able to demonstrably guarantee high quality. In the form of selection or random sampling tests, components are tested for fatigue and wear by means of load tests, for example under pressure and temperature changes. The tests are used for endurance stress testing of various materials and products with different pressure curves and temperatures. We build test benches according to your requirements: e.g. for long-term or short-term tests, under static or pulsating test conditions and depending on other factors. Present us your requirements!

Request for a quote

Germany

The test bench is designed for calibration with critically operated nozzles of domestic gas meters or others such as diaphragm gas meters, ultrasonic meters, thermoelectric gas meters. The test bench is specially designed for the calibration of domestic gas meters (bellows gas meters, ultrasonic meters, thermoelectric gas meters). The test bench is modular - 1x6 to 4x6 clamping positions for the gas meters can be combined. Due to the modular design 1 to 12 gas meters can be tested simultaneously. In parallel, up to twelve additional test pieces can be adapted, run in and leak tested. A magazine consisting of three critical nozzles is used as flow transmitter. Optionally, a nozzle drum with nine combinable nozzles can be used. This allows the generation of up to 512 different flow points with highest accuracy.

Request for a quote

Germany

with adjustable humidity and temperature to simulate the environmental conditions of a test specimen (e.g. household appliances, heating technology) The basis is a standard or climatic chamber (e.g. test kitchen, environmental simulation) with adjustable air humidity and temperature. On the basis of decades of experience in automotive test engineering, EP-E developed a concept in which the air flows in a circle (loop design). The result is a very excellent homogeneous temperature and humidity distribution. Through precise temperature and humidity control, it is possible to set different combinations of air conditioning and thus precisely adjust the required test conditions. The determination of the air flow (exhaust air volume) is carried out via a measuring section with the use of Laminar Flow Elements (LFEs). In order to determine the volume flow, pressure and temperature sensors are used to determine the air volume flow of the climatic chamber(s).

Request for a quote

Do you sell or make similar products?

Sign up to europages and have your products listed

Add my business

Germany

The high-precision calibration laboratory is accredited according to DIN EN ISO/IEC 17025 for flow calibration of flowing gases. The EP calibration laboratory is accredited by the DAkkS according to DIN EN ISO/IEC 17025:2005 for calibrations of gases in-house and on-site under the procedure number D-K-21444-01-00. We offer calibrations for gas flow measurement as well as temperature, humidity and pressure measurements. In addition, we calibrate all measured variables of the test bench directly at your site. Our experienced technicians also check the harmonious interaction of all sensors, so that the entire system is perfectly tuned. The opening of our new calibration laboratory in Asia enables us to offer you even better service internationally.

Request for a quote

Germany

Maintain the high accuracy of your BlowerDoor measuring technology by regularly submitting it to a calibration. Benefit from the high accuracy of the BlowerDoor measuring technology: At ± 4% or rather ± 5% (flow rings D + E), the accuracy of the BlowerDoor testing flow rings – as well as that of the pressure gauge DG-700 (± 1%) or DG-1000 (± 0.9 %) – clearly exceed the minimum legal requirements. The manufacturer’s calibration as well as the calibration with DAkkS-certificate, are subject to the highest quality standards. When calibrated, all measuring systems undergo a preceding functional test. If required, we will gladly provide you with a replacement device at favorable rates and conditions, while your BlowerDoor measuring system is being calibrated or repaired.

Request for a quote

Germany

The KAL 100 / 200 calibration device combines a pressure transmitter and pressure gauge. These can be used to test and calibrate pressure sensors and other pressure gauges for low pressures both quickly and easily. The desired pressure is indicated on the digital display and pressure is generated quickly and precisely through the use of a closed loop, thereby eliminating the need for an external pressure generator.

Request for a quote

Germany

The portable, battery-operated KAL 84 calibration system combines a pressure transmitter and pressure gauge. These can be used to test and calibrate pressure sensors and other pressure gauges for low pressures both quickly and easily. A high degree of accuracy and excellent reproducibility of results combined with a robust design give the system all the functionalities required for laboratory and service applications. Calibration in mmHg (optional) makes the system ideal for applications in accordance with the regulations for users of medical products, e.g. blood pressure monitors and infusion/suction pumps.

Request for a quote

Germany

Verified by Europages

Digital torque meter with data processing function. Tohnichi's TME3 is suitable for checking torque on bottle caps, starting torque test, strength test, and twisting test, etc. Designed to measure rotating torque of precision parts. Ideal for cap testing. Intuitive icons indicate modes: Run, Peak, 1st 2nd Double Peak, Data/Parameter Setting. The 1st and 2nd peaks holding function, especially for bottle cap measurement. Can detect primary peak opening torque (when cap begins turning) and secondary peak (when bridges break). The drop width required for peak detection can be set to prevent mistaken detection of the unstable region. Easy to read LC display gives reliable visibility. Special teardrop shaped poles allows chucking from a minimum diameter of 7 mm to maximum 190 mm. Pole anchors use a corotation prevention mechanism to grasp your work firmly. With the optionally available calibration equipment, the tester can be calibrated by the operator himself if required.

Request for a quote

Germany

Verified by Europages

Digital Torque Gauge with flip-up Display High precision handheld digital torque gauge with integrated LC display to measure small torque. Ideal for measurement, inspection, and tightening of precision machineries and electric devices. Flip-up display can be adjusted for optimal reading and accommodates various testing positions. BTGE(-G) series products are manufactured for the global market and offer a selection of SI, metric and American units of measurement. Equipped with SI calibration as standard. Optionally available with calibration in imperial (ozf·in, lbf·in) or in metric (kgf·cm) units. There are various application types, even for measuring rotating objects. Combined with Measurement Board (No. 809), it can be fixed to use as torque screwdriver checker, etc.

Request for a quote

Germany

Verified by Europages

Digital Torque Gauge with pull-out LC Display High precision handheld digital gauge with integrated LC display to measure small torque. Ideal for torque measurement like rotating torque, click torque of precision machinery, electronic devices, and various assembly components. The digital display simply slides out of the housing and is attached with a curly cord. Use the optional testing stand to secure the gauge while testing or add fixture to secure your test piece. Combined with Measurement Stand (#808), it can be fixed to use as torque screwdriver checker, et al. ATGE-G series devices are manufactured for the global market and offer a selection of SI, metric and American units of measurement. Equipped with SI calibration as standard, optionally available with calibration in anglo-saxon (ozf·in) or in metric (gf·cm) units.

Request for a quote

Germany

Verified by Europages

Learn how to efficiently manage and monitor your measuring and testing equipment. In this training course, you will learn the basics of measuring and test equipment management, the requirements for calibration and documentation. The training is aimed at all those who are responsible for or interested in measuring and testing equipment. Topics of the training course: Measuring and testing equipment management as a pillar of quality assurance; Measuring and test equipment management as part of the quality management system – test equipment officer; Suitability of devices and sensors as measuring and testing equipment; Traceability and calibration; Documentation and employee training; Monitoring and maintenance of the measuring equipment database.

Request for a quote

Germany

Verified by Europages

Learn how to efficiently manage and monitor your measuring and testing equipment. In this training course, you will learn the basics of measuring and test equipment management, the requirements for calibration and documentation. The training is aimed at all those who are responsible for or interested in measuring and testing equipment. Topics of the training course: Measuring and testing equipment management as a pillar of quality assurance; Measuring and test equipment management as part of the quality management system – test equipment officer; Suitability of devices and sensors as measuring and testing equipment; Traceability and calibration; Documentation and employee training; Monitoring and maintenance of the measuring equipment database.

Request for a quote

Germany

To ensure that an instrument provides accurate measurements, regular calibrations are necessary. Calibration means to operate a target-performance comparision using a measuring instrument and a traceable reference. Calibration of instruments is essential in every area where sensitive measurement technology is used, e.g. in the manufacturing of sensors. It is the only way to guarantee quality standards and prevent defects arising in processes and products from the outset. For companies wanting to attain ISO 9001 certification, regular calibration of testing equipment is a requirement. halstrup-walcher has been accredited by the German calibration service DKD and Deutsche Akkreditierungsstelle GmbH (DAkkS) as a calibration laboratory in accordance with DIN EN ISO / IEC 17025 since 1999 – among other things for calibration of pressure measurements.

Request for a quote

Germany

The TransiTec Big Bag filling stations are suitable as standard for filling big bags with a capacity of up to 2 tons. Various options are available to meet the required task. Also a calibratable weighing of the filled Big-Bas. The Big-Bag filling station offers a variety of options: - height-adjustable suspension frame - Tightening of the big bag by means of linear drive - Double big bag filling - vibration table for compacting the products, etc., ... to name just a few.

Request for a quote