• europages
  • >
  • COMPANIES - SUPPLIERS - SERVICE PROVIDERS
  • >
  • plugs and sockets

Results for

Plugs and sockets - Import export

GermanyBonn, Düsseldorf and North Rhine and Westphalia

Germany

Verified by Europages

Wall socket 5602E with 2 slots, for standard plugs in straight or angled form. The complete housing is made of V2A stainless steel and the device carrier made of aluminum. The door can be closed with a locking bolt cylinder and also closes when plugged in. The 5602E on-wall socket is ideal for workshops, cellars and washrooms. Further equipment on request!

Request for a quote

Germany

Verified by Europages

Safe energy and data transmission The igus® Chainflex® cable range offers a choice of over 850 different cables, available from stock. A main focus of the range are the data and bus cables. Solutions based on copper, glass or plastic fiber optic cables are provided for almost all bus systems in industrial use. We continue to provide you with all supply cables for your drive systems such as motor cables with and without brake/tacho cables and the matching feed cables. Ready assembled with plugs and sockets on request. Cost-reducing assembly The use of pre-assembled E-ChainSystems® enables expensive assembly hours at the place of installation to be considerably reduced. Functionally tested systems guarantee that plant components are soon put into operation. Assembly service We would be pleased to send you an offer for complete solutions, including all assembly services. You do not tie up your own resources and you have a trouble-free energy supply system for the future at a fixed price. LBT FLIZZ® - High speeds and accelerations Travel distances up to 120m, travel speed up to 8 m/s Suitable for moving or stationary controls, ideal for all bus systems When light weight is required When quiet, maintenance-free operation is required When rust-proof property is required At -10°C to +60°C constant temperature At accelerations over 10 m/s² Energy supply system for all media, not only electrical Also suitable for outdoor use (with reduced load data) Your benefit from LBT FLIZZ® Guaranteed service life Cost-effective compared with conventional energy supply systems Cable protected against dirt, rain, sun, ice, snow and leaves Insensitive to wind and motion Good resistance to chemicals, solvents, etc. Use of special cables possible, e.g. servo drive cables, fiber optic cables, bus systems etc. almost maintenance free Quick and easy installation due to delivery as a ready-assembled system Easy integration with existing plants Cable length 50% of the travel distance No central cable junction No effort required to maintain carriages Sewage treatment plant Longitudinal scrapers Sand traps Rain water overflow reservoir Galvanizing equipment Cranes Plant construction Space-saving and compact energy supply with LBT FLIZZ® - low maintenance system, delivered pre-fitted with ready-assembled igus® E-Chain Energy supply system protected from wind and weathering. The used materials are weather-resistant, as well as resistant against most chemicals, oils, fats, coolants and solvents Solid plastic with powder-coated support tubes Modular assembly: the system can be enclosed with intermediate panels! Can be delivered pre-fitted Variable fields, which are simply screwed on top of each other Glide rail integrated in the profile

Request for a quote

Germany

Verified by Europages

Sheathing thermocouples can be used anywhere due to their ruggedness and small design. Whether in industry, development or in the lab. The measurement point is hot junction insulated as standard to exclude any falsification of the measurement evaluation through superposition of the offsets. Sheathing thermocouples are freely flexible across their entire length. That means the thermocouple can be integrated in the installation point. The temperature to be measured can therefore be registered near the desired measuring point. A possible connection lead permits simple routing up to the measured-data acquisition. Options are available for the element diameter, element and wire length as well as the type of connection configuration (plug, socket, bare wire ends, etc.).

Request for a quote

Germany

Verified by Europages

Sheathing thermocouples can be used anywhere due to their ruggedness and small design. Whether in industry, development or in the lab. The measurement point is hot junction insulated as standard to exclude any falsification of the measurement evaluation through superposition of the offsets. Sheathing thermocouples are freely flexible across their entire length. That means the thermocouple can be integrated in the installation point. The temperature to be measured can therefore be registered near the desired measuring point. A possible connection lead permits simple routing up to the measured-data acquisition. Options are available for the element diameter, element and wire length as well as the type of connection configuration (plug, socket, bare wire ends, etc.).

Request for a quote

Germany

Verified by Europages

Sheathing thermocouples can be used anywhere due to their ruggedness and small design. Whether in industry, development or in the lab. The measurement point is hot junction insulated as standard to exclude any falsification of the measurement evaluation through superposition of the offsets. Sheathing thermocouples are freely flexible across their entire length. That means the thermocouple can be integrated in the installation point. The temperature to be measured can therefore be registered near the desired measuring point. A possible connection lead permits simple routing up to the measured-data acquisition. Options are available for the element diameter, element and wire length as well as the type of connection configuration (plug, socket, bare wire ends, etc.).

Request for a quote

Germany

Verified by Europages

Sheathing thermocouples can be used anywhere due to their ruggedness and small design. Whether in industry, development or in the lab. The measurement point is hot junction insulated as standard to exclude any falsification of the measurement evaluation through superposition of the offsets. Sheathing thermocouples are freely flexible across their entire length. That means the thermocouple can be integrated in the installation point. The temperature to be measured can therefore be registered near the desired measuring point. A possible connection lead permits simple routing up to the measured-data acquisition. Options are available for the element diameter, element and wire length as well as the type of connection configuration (plug, socket, bare wire ends, etc.).

Request for a quote

Germany

Verified by Europages

Sheathing thermocouples can be used anywhere due to their ruggedness and small design. Whether in industry, development or in the lab. The measurement point comes insulated as standard to exclude any falsification of the measurement evaluation through superposition of the offsets. The connection lead permits simple routing up to the measured-data acquisition. Options are available for the probe diameter and wire length as well as the type of connection configuration (plug, socket, bare wire ends, etc.). Temperature range: -100 °C to +260 °C, continuous Wire type: Teflon with CU shielding, Tmax: +200 °C, continuous

Request for a quote

Germany

Verified by Europages

Sheathing thermocouples can be used anywhere due to their ruggedness and small design. Whether in industry, development or in the lab. The measurement point comes insulated as standard to exclude any falsification of the measurement evaluation through superposition of the offsets. The connection lead permits simple routing up to the measured-data acquisition. Options are available for the probe diameter and wire length as well as the type of connection configuration (plug, socket, bare wire ends, etc.). Temperature range: -100 °C to +180 °C, continuous Wire type: Silicone, Tmax: +180 °C, continuous

Request for a quote

Germany

Verified by Europages

Sheathing thermocouples can be used anywhere due to their ruggedness and small design. Whether in industry, development or in the lab. The measurement point comes insulated as standard to exclude any falsification of the measurement evaluation through superposition of the offsets. The connection lead permits simple routing up to the measured-data acquisition. Options are available for the probe diameter and wire length as well as the type of connection configuration (plug, socket, bare wire ends, etc.). Temperature range: -100 °C to +550 °C, continuous Wire type: Fibreglass with VA braid, Tmax: +450 °C, continuous

Request for a quote

Germany

Verified by Europages

Sheathing thermocouples can be used anywhere due to their ruggedness and small design. Whether in industry, development or in the lab. The measurement point comes insulated as standard to exclude any falsification of the measurement evaluation through superposition of the offsets. The connection lead permits simple routing up to the measured-data acquisition. Options are available for the probe diameter and wire length as well as the type of connection configuration (plug, socket, bare wire ends, etc.). Temperature range: -100 °C to +800 °C, continuous, depending on selected sheathing diameter and measuring medium or atmosphere Wire type: Fibreglass with VA braid, Tmax: +450 °C, continuous

Request for a quote

Germany

Verified by Europages

Sheathing thermocouples can be used anywhere due to their ruggedness and small design. Whether in industry, development or in the lab. The measurement point comes insulated as standard to exclude any falsification of the measurement evaluation through superposition of the offsets. The connection lead permits simple routing up to the measured-data acquisition. Options are available for the probe diameter and wire length as well as the type of connection configuration (plug, socket, bare wire ends, etc.). Temperature range: -100 °C to +800 °C, continuous, depending on selected sheathing diameter and measuring medium or atmosphere Wire type: Teflon with CU shielding, Tmax: +200 °C, continuous

Request for a quote

Germany

Verified by Europages

Sheathing thermocouples can be used anywhere due to their ruggedness and small design. Whether in industry, development or in the lab. The measurement point comes insulated as standard to exclude any falsification of the measurement evaluation through superposition of the offsets. The connection lead permits simple routing up to the measured-data acquisition. Options are available for the probe diameter and wire length as well as the type of connection configuration (plug, socket, bare wire ends, etc.). Temperature range: -100 °C to +1.100 °C, continuous, depending on selected sheathing diameter and measuring medium or atmosphere Wire type: Silicone, Tmax: +180 °C, continuous

Request for a quote

Germany

Verified by Europages

Sheathing thermocouples can be used anywhere due to their ruggedness and small design. Whether in industry, development or in the lab. The measurement point comes insulated as standard to exclude any falsification of the measurement evaluation through superposition of the offsets. The connection lead permits simple routing up to the measured-data acquisition. Options are available for the probe diameter and wire length as well as the type of connection configuration (plug, socket, bare wire ends, etc.). Temperature range: -100 °C to +1.100 °C, continuous, depending on selected sheathing diameter and measuring medium or atmosphere Wire type: Fibreglass with VA braid, Tmax: +450 °C, continuous

Request for a quote

Germany

Verified by Europages

Sheathing thermocouples can be used anywhere due to their ruggedness and small design. Whether in industry, development or in the lab. The measurement point comes insulated as standard to exclude any falsification of the measurement evaluation through superposition of the offsets. The connection lead permits simple routing up to the measured-data acquisition. Options are available for the probe diameter and wire length as well as the type of connection configuration (plug, socket, bare wire ends, etc.). Temperature range: -100 °C to +1.100 °C, continuous, depending on selected sheathing diameter and measuring medium or atmosphere Wire type: Teflon with CU shielding, Tmax: +200 °C, continuous

Request for a quote

Germany

Verified by Europages

Sheathing thermocouples can be used anywhere due to their ruggedness and small design. Whether in industry, development or in the lab. The measurement point comes insulated as standard to exclude any falsification of the measurement evaluation through superposition of the offsets. The connection lead permits simple routing up to the measured-data acquisition. Options are available for the probe diameter and wire length as well as the type of connection configuration (plug, socket, bare wire ends, etc.). Temperature range: -100 °C to +260 °C, continuous Wire type: Teflon with CU shielding, Tmax: +200 °C, continuous

Request for a quote

Germany

Verified by Europages

Sheathing thermocouples can be used anywhere due to their ruggedness and small design. Whether in industry, development or in the lab. The measurement point comes insulated as standard to exclude any falsification of the measurement evaluation through superposition of the offsets. The connection lead permits simple routing up to the measured-data acquisition. Options are available for the probe diameter and wire length as well as the type of connection configuration (plug, socket, bare wire ends, etc.). Temperature range: -100 °C to +260 °C, continuous Wire type: Teflon with CU shielding, Tmax: +200 °C, continuous

Request for a quote

Germany

Verified by Europages

Sheathing thermocouples can be used anywhere due to their ruggedness and small design. Whether in industry, development or in the lab. The measurement point is hot junction insulated as standard to exclude any falsification of the measurement evaluation through superposition of the offsets. Sheathing thermocouples are freely flexible across their entire length. That means the thermocouple can be integrated in the installation point. The temperature to be measured can therefore be registered near the desired measuring point. A possible connection lead permits simple routing up to the measured-data acquisition. Options are available for the element diameter, element and wire length as well as the type of connection configuration (plug, socket, bare wire ends, etc.).

Request for a quote

Do you sell or make similar products?

Sign up to europages and have your products listed

Add my business

Germany

Verified by Europages

Sheathing thermocouples can be used anywhere due to their ruggedness and small design. Whether in industry, development or in the lab. The measurement point is hot junction insulated as standard to exclude any falsification of the measurement evaluation through superposition of the offsets. Sheathing thermocouples are freely flexible across their entire length. That means the thermocouple can be integrated in the installation point. The temperature to be measured can therefore be registered near the desired measuring point. A possible connection lead permits simple routing up to the measured-data acquisition. Options are available for the element diameter, element and wire length as well as the type of connection configuration (plug, socket, bare wire ends, etc.). Temperature range: -100 °C to +1.100 °C, continuous, depending on selected sheathing diameter and measuring medium or atmosphere

Request for a quote

Germany

Verified by Europages

Sheathing thermocouples can be used anywhere due to their ruggedness and small design. Whether in industry, development or in the lab. The measurement point is hot junction insulated as standard to exclude any falsification of the measurement evaluation through superposition of the offsets. Sheathing thermocouples are freely flexible across their entire length. That means the thermocouple can be integrated in the installation point. The temperature to be measured can therefore be registered near the desired measuring point. A possible connection lead permits simple routing up to the measured-data acquisition. Options are available for the element diameter, element and wire length as well as the type of connection configuration (plug, socket, bare wire ends, etc.). Temperature range: -100 °C to +1.100 °C, continuous, depending on selected sheathing diameter and measuring medium or atmosphere Wire type: Silicone, Tmax: +180 °C continuous

Request for a quote

Germany

Verified by Europages

Sheathing thermocouples can be used anywhere due to their ruggedness and small design. Whether in industry, development or in the lab. The measurement point is hot junction insulated as standard to exclude any falsification of the measurement evaluation through superposition of the offsets. Sheathing thermocouples are freely flexible across their entire length. That means the thermocouple can be integrated in the installation point. The temperature to be measured can therefore be registered near the desired measuring point. A possible connection lead permits simple routing up to the measured-data acquisition. Options are available for the element diameter, element and wire length as well as the type of connection configuration (plug, socket, bare wire ends, etc.). Temperature range: -100 °C to +1.100 °C, continuous, depending on selected sheathing diameter and measuring medium or atmosphere Wire type: Fibreglass with VA braid, Tmax: +450 °C continuous

Request for a quote

Germany

Verified by Europages

Sheathing thermocouples can be used anywhere due to their ruggedness and small design. Whether in industry, development or in the lab. The measurement point is hot junction insulated as standard to exclude any falsification of the measurement evaluation through superposition of the offsets. Sheathing thermocouples are freely flexible across their entire length. That means the thermocouple can be integrated in the installation point. The temperature to be measured can therefore be registered near the desired measuring point. A possible connection lead permits simple routing up to the measured-data acquisition. Options are available for the element diameter, element and wire length as well as the type of connection configuration (plug, socket, bare wire ends, etc.). Temperature range: -100 °C to +1.100 °C, continuous, depending on selected sheathing diameter and measuring medium or atmosphere Wire type: Teflon with CU shielding, Tmax: +200 °C continuous

Request for a quote

Germany

Verified by Europages

Sheathing thermocouples can be used anywhere due to their ruggedness and small design. Whether in industry, development or in the lab. The measurement point is hot junction insulated as standard to exclude any falsification of the measurement evaluation through superposition of the offsets. Sheathing thermocouples are freely flexible across their entire length. That means the thermocouple can be integrated in the installation point. The temperature to be measured can therefore be registered near the desired measuring point. A possible connection lead permits simple routing up to the measured-data acquisition. Options are available for the element diameter, element and wire length as well as the type of connection configuration (plug, socket, bare wire ends, etc.). Temperature range: -100 °C to +750 °C, continuous, depending on selected sheathing diameter and measuring medium or atmosphere

Request for a quote

Germany

Verified by Europages

Sheathing thermocouples can be used anywhere due to their ruggedness and small design. Whether in industry, development or in the lab. The measurement point is hot junction insulated as standard to exclude any falsification of the measurement evaluation through superposition of the offsets. Sheathing thermocouples are freely flexible across their entire length. That means the thermocouple can be integrated in the installation point. The temperature to be measured can therefore be registered near the desired measuring point. A possible connection lead permits simple routing up to the measured-data acquisition. Options are available for the element diameter, element and wire length as well as the type of connection configuration (plug, socket, bare wire ends, etc.). Temperature range: -100 °C to +750 °C, continuous,depending on selected sheathing diameter and measuring medium or atmosphere Wire type: Fibreglass with VA braid, Tmax: +450 °C

Request for a quote

Germany

EMKA offers a comprehensive product range of ingenious locking technology from a single source. The modular program structure allows a unique variety of components: quarter turns, locking-systems, handles, hinges and gasketings. The high quality and product standards are guaranteed by an excellent manufacturing know-how and by the certified process control according to ISO 9001. for location of socket for plug please refer to rear of hinge this hinge can be installed with aluminium profiles from several renowned manufactures this hinge offers versatility due to several location options for plugs on the rear for four plugs, supplied with each of the hinges, provide protection against twisting and are suitable for slots of N = 8 and 10 or N = 7 and 10 mm (other N-dimensions on request)

Request for a quote