• europages
  • >
  • COMPANIES - SUPPLIERS - SERVICE PROVIDERS
  • >
  • fillers

Results for

Fillers - Import export

GeorgiaManufacturer/producer

Georgia

For transmission and distribution of electric power at stationary devices with rated voltage 0,660kV and 1 kV frequency 50Hz. For straining in the air where there is no danger of mechanical damage of the cable, also for laying into channels without influence of stretching forcesThe copper cores with section 1,5-6mm2 inclusive are produced of single wire of 1 class flexibility, 10-240mm2 inclusive with twisted multi-core wires of 2 class flexibility, according to standard IEC 60228:2004. Number of cores in the cable 1,2,3,4,52,5-16mm2-450m; 25-70mm2-300m; 95-240mm2-200min case of supply in bundles the construction length is agreed with the customer. In case of agreement with the customer cables of different construction lengths can be produced

Request for a quote

Georgia

For fixed installation indoors, outdoors, in ground and in waterThe structure of conductor core is single-wire and conforms to 1or 2 class flexibility according to the standard IEC 60228:2004. On fillers of insulated sheaths a round copper wire (10-12) net and copper foil is wound, which performs protective and neutral cores function. The sections of conductor cores are: 1,5-10,0mm2 Number of conductor cores: 1,5-2,5mm2 4-5-7-10-12-14-19-24. 4-6mm2 4-5-7 10mm2 4-5Label attached to wooden drum or bundle, or in case of request of the customer with inscription on top: “JSC Sakcable” cable brand, year of manufacture. Labeling of conductor cores with colors or numbers with inscription on the surface of insulated cores.

Request for a quote

Georgia

For laying in ground, open air, in concrete, inside buildings, in cable channels, in electrical stations, in industrial plants and in the commutation systems where there is no danger of mechanical damage of the cable. Because the permissible operating temperature of the conductor is + 90 0C. Core isolation (XLPE) polyethylene provides higher current loadThe aluminum cores with section 2,5-16mm2 inclusive are produced of single wire of 1 class flexibility, 25-240mm2 inclusive with twisted multi-core wires of 2 class flexibility, according to standard IEC 60228 : 2004. Number of cores in the cable 1,2,3,4,5.Label attached to wooden drum or bundle, or in case of request of the customer with inscription on top: “JSC Sakcable” cable brand, date of production. Labeling of conductive cores with colors or figures 0,1,2,3,4 with inscription on the top of insulated cores

Request for a quote

Georgia

For transmission and distribution of electric power at stationary devices with rated voltage 0,660kV and 1 kV frequency 50Hz. For straining in the air where there is no danger of mechanical damage of the cable, also for laying into channels without influence of stretching forcesInstallation temperature: -150C. The max. allowable core heating temperature in short circuit with duration of not more than 4 seconds must not be above 1600C The conductor is resistant to 98% relative air humidity under +350C conditions Conductive lobe for long-term allowable heating temperature +700CThe aluminum cores with section 2,5-50mm2 inclusive are produced with single wire of 1 class flexibility, 70-240mm2 inclusive with twisted multi-core wires of 2 class flexibility, according to standard 22483-77. Number of cores in the cable 1,2,3,4,5

Request for a quote

Do you sell or make similar products?

Sign up to europages and have your products listed

Add my business
Filters

Results for

Fillers - Import export

Number of results

4 Products

Countries