• europages
  • >
  • COMPANIES - SUPPLIERS - SERVICE PROVIDERS
  • >
  • cable laying

Results for

Cable laying - Import export

Georgia

Georgia

For transmission and distribution of electric power at stationary devices with rated voltage 0,660kV and 1 kV frequency 50Hz. For stretching in the air where there is no danger of mechanical damage of the cable, also for laying into channels without influence of stretching forces. While laying the cables together, they are flame retardantThe copper cores with cross section 1,5-6mm2 inclusive are produced with 1 class flexibility,10-240mm2 are produced with twisted multi-core 2 calass flexibility according to standard 22483-2012. Number of cores in the cable 1,2,3,4,5.

Request for a quote

Georgia

For transmission and distribution of electric power at stationary devices with rated voltage 0,660kV and 1 kV frequency 50Hz. For laying in ground, for overhead, into the concrete, for laying into cable channels. Using in electrical stations, in industrial equipment and in commutation systems. Working temperature on the conductor +90 0C. While laying the cables in groups, they are flame retardantThe aluminum cores with section 2,5-50mm2 inclusive are produced with one wire of 1 class flexibility, 70-240mm2 inclusive with twisted multi-core wires 2 class flexibility, according to standard IEK60228 : 2004. According to customer requested, it’s possible to produce cross sections 16:50 with multi-core wires. Number of cores in the cable 1,2,3,4,5in case of supply in bundles the construction length is agreed with the customer. In case of agreement with the customer cables of different construction lengths can be produced

Request for a quote

Georgia

For transmission and distribution of electric power at stationary devices with rated voltage 0,660kV and 1 kV frequency 50Hz. For stretching in the air where there is no danger of mechanical damage of the cable, also for laying into channels without influence of stretching forces. While laying the cables in a single layer, they are flame retardantThe copper cores with section 2,5-25mm2 inclusive are produced of single wire of 1 class flexibility, accorgind to gost standard 22483-2012. Number of cores in the cable 2,3.in case of supply in bundles the construction length is agreed with the customer. On wooden drum no less than 450m. One batch can contain no more than 20% of cable length not less than 50m.

Request for a quote

Georgia

For transmission and distribution of electric power at stationary devices with rated voltage 0,660kV and 1 kV frequency 50Hz. For stretching in the air where there is no danger of mechanical damage of the cable, also for laying into channels without influence of stretching forcesThe aluminum cores with section 2,5-25mm2 inclusive are produced of single wire of 1 class flexibility according to Gost standard 22483-2012. Number of cores in the cable 2,3.The aluminum cores with section 2,5-25mm2 inclusive are produced of single wire of 1 class flexibility according to Gost standard 22483-2012. Number of cores in the cable 2,3.

Request for a quote

Georgia

For fixed connection on electric appliances, equipment, gathering mounts of electric distribution appliances for rated alternating voltage 660V, up to 100 Hz , or direct current 1000V. Used for laying in buildings, channels, tunnels if there is no danger of mechanical influence on the cables. During laying in single layer the cable is flame retardantThe structure of conductor core is single-wire and conforms to 1 class flexibility according to the standard 22483-2012. The section of conductor core is 2,5; 4; 6; 10mm2. Number of cores in the cable: 2.5mm2-4, 5, 7, 10, 14, 19; 27; 37 4: 10mm2-4, 7, 10 During laying in single layer the cable is flame retardantIn each bundle by existence of counting pair, which differs in color from other cores. Labeling can be done by means of inscription of separate numbers on insulated cores or distinctive colors of insulation can be used. While numeric labeling the color

Request for a quote

Do you sell or make similar products?

Sign up to europages and have your products listed

Add my business

Georgia

For transmission and distribution of electric power at stationary devices with rated voltage 0,660kV and 1 kV frequency 50Hz. For straining in the air where there is no danger of mechanical damage of the cable, also for laying into channels without influence of stretching forcesInstallation temperature: -150C. The max. allowable core heating temperature in short circuit with duration of not more than 4 seconds must not be above 1600C The conductor is resistant to 98% relative air humidity under +350C conditions Conductive lobe for long-term allowable heating temperature +700CThe aluminum cores with section 2,5-50mm2 inclusive are produced with single wire of 1 class flexibility, 70-240mm2 inclusive with twisted multi-core wires of 2 class flexibility, according to standard 22483-77. Number of cores in the cable 1,2,3,4,5

Request for a quote

Georgia

For transmission and distribution of electric power at stationary devices with rated voltage 0,660kV and 1 kV frequency 50Hz. For straining in the air where there is no danger of mechanical damage of the cable, also for laying into channels without influence of stretching forcesThe copper cores with section 1,5-6mm2 inclusive are produced of single wire of 1 class flexibility, 10-240mm2 inclusive with twisted multi-core wires of 2 class flexibility, according to standard IEC 60228:2004. Number of cores in the cable 1,2,3,4,52,5-16mm2-450m; 25-70mm2-300m; 95-240mm2-200min case of supply in bundles the construction length is agreed with the customer. In case of agreement with the customer cables of different construction lengths can be produced

Request for a quote
Filters

Results for

Cable laying - Import export

Number of results

8 Products

Countries