• europages
  • >
  • COMPANIES - SUPPLIERS - SERVICE PROVIDERS
  • >
  • gas calibration

Results for

Gas calibration - Import export

United Kingdom

Our non-refillable calibration gas canisters are designed specifically for the calibration and bump testing of single and multigas analysers. We offer a wide range of gas mixtures, with the option of multigas mixtures too. Our 34L, 58L, and 110L gas canisters provide the ideal solution for functional testing of gas detection and analytical equipment and being lightweight and compact means they can be easily carried in the workshop or on site. All of the canisters in our range are disposable and can be recycled when empty by using our handy recycling tool.

Request for a quote

France

Verified by Europages

The MGC101 system automatically performs zero, precision, span and multi-point calibrations using NO, NO2, SO2, CO, 03, hydrocarbons and other gases.

Request for a quote

Germany

Verified by Europages

The Atlas HVFAA Horizontal Vertical Flame Chamber provides the most accurate means for determining the flammability of aircraft cabin and cargo compartment materials, liners and waste stowage compartment materials, and electric wire. The large volume chamber prevents oxygen depletion during tests. Three digital timers with remote control make specimen event timing precise and convenient. To ensure accurate and repeatable tests, an optional burner flame temperature verification kit is available. The HVFAA is the optimal instrument for conducting repeatable FAA flammability tests. Designed to be used for testing in accordance with FAA's Aircraft Material Fire Test Handbook DOT/ FAA/AR-00/12, Chapters 1.0 - 4.0 (FAR 25.853, 25.855, 25.1359) Draft-free large volume (>0.5m 3) flame chamber Vertical, Horizontal, 45 Degree and 60 Degree Wire Test Packages Sliding hand ports for chamber access Regulated gas control system Calibrated gas flow meter with precision needle valve adjustment ASTM D5025 Bunsen burner with remote positioning Stopwatch plus three handset operated digital timers Tempered glass sliding window Interior inspection light Flame height gauge High temperature exhaust blower with variable speed control ASTM D5207 flame confirmation kit

Germany

Over the last few years, we at EP-E have designed and introduced a series of primary standards for gases, designed for use in calibration laboratories. As a technology partner of the Physikalisch-Technische Bundesanstalt (PTB) in Braunschweig, our solutions are based on the highest standards. The EP gas bell plungers generate a volume flow which is traceable to the SI units length and time. The pistons are driven by a stepper motor via a spindle. In the initial state one piston is fully retracted and the other fully extended. The volume flow can be set with high precision via the piston cross section and the travel speed. At the end of the calibration process, both pistons are in the opposite position to the initial position. The calibration device is preferably operated with air, which can be supplied with up to 6 bar. The EP gas bell pistons convince by highest measuring accuracy up to 0.15% (k=2).

Request for a quote

Germany

Over the last few years, we at EP-E have designed and introduced a range of primary standards designed for use in calibration laboratories. As a technology partner of the Physikalisch-Technische Bundesanstalt (PTB) in Braunschweig, Germany, our solutions are based on the highest standards. The EP gas bell plungers generate a volume flow which is traceable to the SI units length and time. The pistons are driven by a stepper motor via a spindle. In the initial state one piston is fully retracted and the other fully extended. The volume flow can be set with high precision via the piston cross section and the travel speed. At the end of the calibration process, both pistons are in the opposite position to the initial position.

Request for a quote

Do you sell or make similar products?

Sign up to europages and have your products listed

Add my business

Germany

The high-precision calibration laboratory is accredited according to DIN EN ISO/IEC 17025 for flow calibration of flowing gases. The EP calibration laboratory is accredited by the DAkkS according to DIN EN ISO/IEC 17025:2005 for calibrations of gases in-house and on-site under the procedure number D-K-21444-01-00. We offer calibrations for gas flow measurement as well as temperature, humidity and pressure measurements. In addition, we calibrate all measured variables of the test bench directly at your site. Our experienced technicians also check the harmonious interaction of all sensors, so that the entire system is perfectly tuned. The opening of our new calibration laboratory in Asia enables us to offer you even better service internationally.

Request for a quote

Germany

You always know what is going on in your plant: Gas detection system Statox 505 compliant to SIL 2 Standard Intelligent Gas Sensors for AsH 3, Cl 2, ClO 2, CO, COCl 2, H 2, H 2S, HCl, HCN, HF, N 2H 4, NH 3, NO 2, O 2, O 3, PH 3 and SO 2 The Statox 505 new 4 – 20 mA Transmitter for toxic gases and oxygen features everything that a new gas detection instrument of the latest generation needs: State of the Art components (hardware and software), smart sensor technology, “heartbeat” sensor control and complete system diagnostics on board. What makes the Statox 505 so reliable? In process monitoring, the status of plant components in case of a failure is becoming more and more a critical issue. The standards DIN EN 61508 as well as the product standard DIN EN 50402 are powerful tools to calculate the probability of a failure on demand. The Statox 505 complies with all of the requirements of these standards. It obtained the safety integrity level SIL 2. This provides a reliable database for the user to calculate the safety standard of his plant. If the Statox 505 is operated as a SIL 2 component, a so called “proof test” in certain time intervals is mandatory. All OK All important parameters such as sensor „heartbeat“, signal output, calibration, zero, sensitivity, temperature, sensor memory, amplifier, CPU, power supply etc. are continuously monitored for proper function. In case of a failure, an alarm will be triggered. Thus the system cannot fail without the error being noticed. A green LED signalizes the system status. The display and the controls are located at the inside of the housing - well protected from the elements. Minimum time and work in the field The sensors of the Statox 505 are plug and play technology. Each sensor has a F-RAM on board which communicates all relevant parameters to the sensor head: Gas, measuring range, last calibration, ex works calibration, response time etc. The sensors can easily be calibrated in the shop. For the user this means that he never ever will have to do calibration work in the harsh elements (wind, rain, cold, heat). No more lugging heavy test equipment and gas cylinders into the field. All the user has to do in the field, is plug the sensor back in. To do that, you don`t even need a tool! While the sensor is getting calibrated in the shop, the sensor cartridge stays in place and protects the sensor head from dust and rain. Trouble- free wall - or pipe mounting The Statox 505 comes with a mounting plate for either wall - or pipe mounting. No need to open the sensor head for plant installation Storage temperature

Request for a quote

Russia

While introducing a new line of gas analysis equipment to the market, we offer a fundamentally new concept of gas analysis systems based on replaceable modular gas analyzers GAOS SENSON-SM-9001. Advantages: - Radically reduced downtime required for calibration and repair - Reduced spare equipment costs - Increase the offline resource of remote objects - Extra-low delivery times New concept: - simplifies the replacement of gas analyzers for calibration and in the event of a malfunction – in the case of GAOS SENSON it is as simple as changing a light bulb, no need to dismantle/change the entire device. That is, it is enough to change a lightbulb, not a chandelier; - it dramatically reduces the stock of replacement systems in volume and cost – only the GAOS SENSON-SM-9001 modules are needed (supply of light bulbs, not chandeliers); - requirements for the qualification of staff (there is only one requirement – accuracy) are reduced.

Request for a quote

France

Detects Explosive and Toxic Gas, or Oxygen Non-Intrusive Calibration Smart Infrared Gas Sensors HART Communication Protocol (NEW) MODBUS Communication Programmable Relays Dual Gas Sensing (*) versions with local visible alarm are to be installed in ordinary locations only

Request for a quote

Germany

10 litres calibration gas (100 ppm H 2 in nitrogen) for all FAN H 2 breath test devices. Compressed in an 1–litre aluminium can, at least 12 calibrations can be readily achieved.

Request for a quote

Germany

Control valve and Flow indicator for use with calibration gas cylinder. Flow meter markings are nominally 0.5 & 1.0 litres/min.

Request for a quote