Gas analysis - Import export

Germany

Verified by Europages

thick rubber stopper

Request for a quote

Germany

Analysing the gas quality in the gas network is essential to monitor technical specifications and ensure correct billing. The GasPro is a mobile gas sampler, with which cyclic sampling can be carried out easily and flexibly at any point from dry gas networks. The samples are collected in a sample cylinder in the GasPro and can then be analysed in a laboratory. The GasPro allows the separation of sampling and sample analysis and is therefore more cost effective and flexible than for example fixed installed gas chromatographs.

Request for a quote

Russia

GAOS MS mass spectrometers provide fast, accurate, and comprehensive gas analysis in real-time. Operational characteristics: - Modular configuration, quick replacement of units for maintenance and repair; - Protective performance according to customer requirements; - Continuous operation 24 hours for 6 to 12 months without servicing the vacuum system; - Automatic algorithm of work with functions of diagnostics, adjustment, calibration and operational control of measurement accuracy. Depending on analytical applications, GAOS MS process mass spectrometers are equipped with various modifications of the sample preparation system. Continuous sampling of the gas probe under conditions: - Temperature up to 1200 °C; - Dust content up to 30 g/m3; - Pressure (10-3÷3) bar; - Presence of condensate, aggressive gases;

Request for a quote

Germany

Our Gas Quality Competence Centre answers chemical analysis and process engineering questions in all matters connected with the transportation and use of natural gas. Our Competence Centre uses high-performance methods and processes for the analysis of gases and accompanying substances and can draw on many years of experience in the operation of our transmission system and cooperation with customers. The full range of our laboratory services if of course also available to other companies and organisations. They include: Determination of natural gas compositions in accordance with DVGW Code of Practise G 260 Natural gas analyses up to C14 Determination of trace concentrations of accompanying substances Water analyses on preheaters in accordance with DVGW Code of Practise G 495 Natural gas safety data sheet and much more Our Gas Quality Competence Centre is certified to DIN EN ISO 9001. The natural gas analysis laboratory is accredited to DIN EN ISO/IEC 17025.

Request for a quote

Germany

The dual channel pyrodetector is specially designed for the measurement of carbon monoxide (CO) using an optical filter with a CWL of 4650 ± 40 nm and a HBW of 180 ± 20 nm. Medical, industrial gas analysis and environmental technology are typical fields of application for the MPS2SENS carbon monoxide. The dual detector meets demanding needs at ambient temperatures ranging from -20 to 85 °C. It has a particularly high detectivity of up to 4.0*10^8 cm√Hz/W and sensitivity of up to 200000 V/W. An additional reference channel (CWL: 3910 ± 28, HBW: 70 ± 10 nm) completes the product. The detector is equipped with 2 chips with a thin film membrane made of ceramic-pyroelectric material as technological basis. The unique detector design of Micro-Hybrid enables the high read-out rate up to 100 Hz as well as the short response time and guarantees precise and fast measurement results for NDIR gas analysis.

Request for a quote

Germany

The NDIR bundle N2O is made up of optimally matched thin film infrared emitters and a corresponding IR thermopile detector to measure nitrous oxide in gas mixes. The kit has a short delivery time and therefore achieves measurement results in a short time. This is especially an advantage for developers in research projects with a limited time span. The two-channel detector's optical filter has been optimized for the absorption spectrum of N2O (CWL: 4525 ± 20 nm / HBW: 83 ± 6 nm) and can provide important data, especially in the analysis of exhaust gases in the automotive, railway and marine sectors, the monitoring of industrial exhaust emissions and environmental monitoring.

Request for a quote

Germany

The dual-channel thermopile is optimized for the measurement of carbon monoxide (CO) through an optical filter with a CWL of 4650 ± 40 nm and a HBW of 180 ± 20 nm. Medical technology, process or room air analysis are typical application fields for the MTS2SENS200 carbon monoxide. The MTS2SENS200 carbon monoxide dual detector is suitable for demanding applications at ambient temperatures from -20 to 85 °C. It has a particularly high detectivity. It has a particularly high detectivity of up to 6.27*10^8 cm√Hz/W and a sensitivity of up to 171 V/W. This signal quality is comparable to pyro detectors. The integrated thermistor for reference temperature determination and an additional reference channel (CWL: 3910 ± 28, HBW: 70 ± 10 nm) complete the product. The detector has as technological basis 2 chips with 200 bismuth antimony/antimony thermocouples each. Other applications of the detector include metabolic monitoring, spirometry, biotechnology and food technology.

Request for a quote

Germany

This 2 channel premium pyrodetector offers an optimal performance for the measurement of carbon compounds (CxHy) through the narrowband infrared filter with a CWL of 3400 ± 20 nm and a HBW of 140 ± 20 nm as well as an additional reference channel (CWL: 3910 ± 28, HBW: 70 ± 10 nm). The particularly high detectivity of up to 4.0*10^8 cm√Hz/W as well as the very high sensitivity of up to 200000 V/W guarantee precise and long-term stable measurement results. The pyroelectric detector allows demanding applications in gas measurement and gas analysis in various industries such as aerospace, medical or industrial process technology. Two detector chips with a ceramic pyroelectric thin film diaphragm form the core of this 2 channel pyroelectric detector. The low microphone effect due to the low membrane mass, the very low temperature dependence and an amplified signal in current modes enhance the measurement signals of the dual IR detector.

Request for a quote

Germany

The IR Thermopile can be used to measure methanol (CH4O / half structure formula: CH3OH) & ethanol (C2H5OH) at ambient temperatures between -20 and 85 °C. With its very high detectivity of up to 6.27*10^8 cm√Hz/W and a sensitivity of up to 171 V/W, the 2-channel detector is the high end solution for demanding applications in medical technology or industrial production and process applications. The optical filter window with a CWL of 9663 ± 80 nm and a HBW of 240 ± 40 nm is specifically designed for NDIR gas analysis of these typical alcohol compounds. These signal values, which are comparable to pyrodetectors, are achieved by the interaction of chip design, integrated thermistor for reference temperature determination, an interference absorber and backgassing with krypton. The precise measurement results are further secured by the second reference channel (CWL: 5060 ± 25, HBW: 100 ± 15 nm).

Request for a quote

Germany

The narrow-band filter of the MTS2SENS200 carbon dioxide with a CWL of 4265 ± 25 nm and an HBW of 120 ± 10 nm is optimized for the measurement of carbon dioxide (CO2) with reference channel (CWL: 3910 ± 28, HBW: 70 ± 10 nm). The detector is characterized by an integrated thermistor for reference temperature determination and an interference absorber. They both ensure that the signal is converted as efficiently as possible from radiant energy to thermal energy. The basis of the IR thermopile MTS2SENS200 carbon dioxide are 2 chips with 200 bismuth-antimony/antimony thermocouples each. Thanks to them and the filling with krypton, the detector convinces with a detectivity of up to 6.27*10^8 cm√Hz/W and sensitivity of up to 171 V/W. The signal quality is comparable to pyroelectric detectors. The detector can be used at ambient temperatures between -20 and 85 °C in numerous industrial, aerospace and medical applications: Exhaust gas measurement, breath gas analysis or patient monitoring.

Request for a quote

Germany

The NDIR bundle N2O is made up of optimally matched thin film infrared emitters and a corresponding IR thermopile detector to measure nitrous oxide in gas mixes. The kit has a short delivery time and therefore achieves measurement results in a short time. This is especially an advantage for developers in research projects with a limited time span. The two-channel detector's optical filter has been optimized for the absorption spectrum of N2O and can provide important data, especially in the analysis of exhaust gases in the automotive, railway and marine sectors, the monitoring of industrial exhaust emissions and environmental monitoring.

Request for a quote

Germany

The 2 channel premium pyrodetector is specially designed for the analysis of nitric oxide (NO). The optical filter with a CWL of 5300 ± 30 nm and a HBW of ± 20 nm as well as an additional reference channel (CWL: 3910 ± 28, HBW: 70 ± 10 nm) optimize the measurement results of the dual IR detector. Its main application lies in the measurement of process gases or exhaust gases in industrial production and process engineering. Storage and operation can take place between -20 and 85 °C. The particularly high detectivity of up to 4.0*10^8 cm√Hz/W as well as the very high sensitivity up to 200000 V/W provide an extraordinary signal quality in the sector of pyroelectric detectors. Two sensor chips with a thin film CPM membrane form the core of the dual detector MPS2SENS nitrogen monoxide. Thanks to the Ceramic Pyroelectrical Material (CPM) and the unique product design the detector features a high read-out rate up to 100 Hz as well as a short response time.

Request for a quote

Germany

The NDIR bundle CO2 is a set of perfectly matching components for the gas analysis of carbon dioxide and offers research teams, institutes and laboratories the right solution for the demand of short term required IR components in small volumes. Micro-Hybrid is combining a NAC-based IR emitter with reflector of the JSIR 350 series with the highly sensitive thermopile dual detector of the MTS 2 SENS series. The narrow band filter of the dual detector is optimized to absorb carbon dioxide (CWL: 4265 ± 25 nm / HBW: 120 ± 10 nm) and has an additional reference channel (CWL: 3910 ± 28, HBW: 70 ± 10 nm). Designed for use in research projects in the fields of cell growth, plant cultivation or industrial gas measurement, our NDIR bundle CO2 provides developers with immediate results in gas analysis.

Request for a quote

Germany

The MTS2SENS200 sulfur dioxide is tuned by its filter window for the analysis of sulfur dioxide (SO2) with a CWL of 7300 ± 50 nm and a HBW of 180 ± 20 nm. The signal strength of the detector is comparable to that of a pyro detector - high detectivity of up to 6.27*10^8 cm√Hz/W and high sensitivity of up to 171 V/W with krypton as filling gas. The dual-channel IR thermopile for NDIR gas analysis has 2 chips in the core, each with 200 BiSb/Sb thermopairs. The interference absorber, an integrated thermistor for reference temperature determination and the reference channel (CWL: 5060 ± 25, HBW: 100 ± 15 nm) are further important product features for long-term use in demanding applications. The MTS2SENS200 sulfur dioxide provides reliable measurement values in environments between -20 and 85 °C, e.g. for biotechnology or quality assurance. Our sales team will be happy to discuss further scale prices and possible individual customizations with you.

Request for a quote

Germany

BlueVary is a maintenance free gas analyzer for variable biotechnological applications. By selectable sensor cartridges different measuring tasks ranging from microbial, cell culture to monitoring of algae and biogas processes can be covered by just one device. The analyzer consists of a basis element with measurement places for two of the variable sensor cartridges. The third place holds a cartridge to compensate pressure and/or humidity. The integrated display ensures an overview about sensor and concentrations at any time. As already known from the forerunner analyzers BlueVary can be mounted on each fermenter from lab to production scale by using different mechanical connections without being limited by fermenter brand or manufacturer. Various data outputs are available. Annual maintenance is not necessary. In combination with the open software BlueVis the BlueVary turns into a versatile, effective tool for real-time online monitoring and optimization of bioprocesses of any kind.

Request for a quote

Germany

Oxygen is essential for life. Measuring oxygen concentrations plays a central role in controlling biotechnological processes . No matter if fermentations, scale-up studies, bioproductions in lab or industrial scale, the BCP-O2 sensor determines the oxygen concentration in realtime (real time monitoring) in a very convenient way. By measuring the oxygen concentrations oxygen limitations can be avoided and conclusions to metabolic activity can be drawn. With the help of measuring the oxygen important process parameters as OTR oxygen transfer rate or respiratory quotient RQ can be determined. Using BCP-O2 simplifies process optimization in bioprocessing and makes it efficient and precise. In contrast to other sensors the BCP-O2 has in integrated automated temperature and pressure compensation and can be connected to each and every fermenter type. BCP-O2 doesn´t need a minimum flow rate and thus can be applied from small (lab) scale (e.g shake flask) up to the large industrial scale.

Request for a quote

Germany

The BCpreFerm is a whole gas analysis for scale-up processes. Made for the analysis of metabolic processes, the model is composed of up to 6 CO2- and O2-senors, a BACCom data multiplexer box, and the BlueVis-software for automatic data recording. Growth is controlled through a parallel analysis of CO2 and O2, a display of OTR, CTR and RQ, and through defined trial conditions. The system uses a modular design which enables connection to shake flasks, as well as to fermenters. It can also be attached to existing bioreactors. The use of additional gas coolers, lines, pumps and valves, and the complicated processing of gases is no longer necessary. The instrument can be used for cultivations in shake flasks and fermenters and further applications.

Request for a quote

Do you sell or make similar products?

Sign up to europages and have your products listed

Add my business

United Kingdom

Verified by Europages

A broad variety of gas transmission cells are : Gas Cells analysis of gas & vapour phase components in IR optical spectroscopy. These range from short path length gas cells for percent level concentration measurement, to long path length gas cells for part-per-billion concentrations. Options include fixed and variable path length gas cells, as well as ambient temperature and heated gas cells. The windows that can be used with the gas cell include NaCl, KBr, CaF2, BaF2, or ZnSe infrared transmission windows, which are mounted in an optical spectrometer. Knight Optical supply high quality Gas Cells optical components made to our exacting specification. For more information read the PDF

Request for a quote

United Kingdom

Verified by Europages

Sapphire (Al2O3) is one of the hardest minerals and optical materials available for use in the range from UV up to 5µm. Sapphire is birefringent and if its use is for critical optical application then the crystal might have to be cut along the zero degree plane, or C-Cut. Random cut is usually cut along a plane that is 60° off-axis as the growth in this direction is the easiest to grow. Random cut is anything that is not the C-Cut angle. Sapphire can fluoresce depending upon the concentration of other minerals within the lattice, for example Iron (Fe) or Chromium (Cr). Clear Sapphire might fluoresce orange when illuminated by UV light if impurities are in the crystal. Fluorescent free Sapphire has to be grown from 'pure' feedstock and seed and in an environment that cannot place impurities into the lattice. Click PDF link to read more …...

Request for a quote

Germany

Verified by Europages

UNLOCK YOUR PROCESS Unparalleled Performance for Increased Yields and Maximum Uptime The ever increasing price of silicon wafers and demand for finished products means that scrapped wafers cost more than ever before. Thus, understanding your process and monitoring for defects has become a much higher priority in semiconductor fabrication centers. The Transpector MPH Gas Analysis System is designed to unlock your process with industry leading performance for all of your gas analysis applications to help maximize chip yields and minimize tool downtime. Combined with a low overall cost of ownership and high mean-time-between-failures, Transpector MPH helps your bottom line more than any other residual gas analyzer (RGA) on the market. INFICON has leveraged its expertise in gas analysis process control equipment to create an RGA with industry-leading data collection speed, minimum detectable partial pressure and signal-to-noise ratio. All this, without sacrificing any of the...

Request for a quote

Germany

Verified by Europages

Some variants of the QMG 700 will be discontinued Jan 31, 2018 Exceeding Detection Limits with Superior Stability and Refined Resolution Rapid advancements in semiconductor manufacturing technology rely on swift and dependable gas analysis solutions. In the fab or in the lab, select the INFICON QMG 700 Analytical Mass Spectrometer to break through detection barriers and propel your process to the next level of innovation. The QMG 700 provides unparalleled performance and adaptability in a modular design. Enhance your competitive edge with the QMG 700, and achieve a superior level of measurement capability. Select from a wide range of ion source, mass filter, and RF power supply options, to tailor your QMG 700 to specific applications. The QMG 700 boasts more than nine decades of dynamic range and ppb detection limits, making it the ideal instrument for ultra high vacuum measurements. QMG 700 provides unit resolution across its entire mass range, and even higher resolution for...

Request for a quote

Germany

Verified by Europages

THE STANDARD IN GAS ANALYSIS Excellent Performance and Great Value for General Vacuum Applications As manufacturing technologies advance and quality standards change, the need to understand your process and maintain product quality is more important than ever. Transpector MPS can help you optimize your process by monitoring process conditions, detecting contaminants, and checking for leaks. Transpector MPS offers the robust performance of the Transpector brand of RGA at an excellent value for our customers. Transpector MPS is available in both 100 amu and 200 amu versions, which gives you the flexibility of performing a wide variety of functions including general leak detection, vacuum diagnostics, and hydrocarbon analysis. This versatility makes Transpector MPS the sensor of choice for vacuum furnace, heat treating, and vacuum coating applications. (1) at 10% of peak height (2) during an eight hour period, after a half hour warm up; in FC mode only (3) 256 millisecond dwell time

Request for a quote

Germany

Verified by Europages

Electrical gas heaters for operating pressure up to 500 bar - Seal gas heaters, fuel gas heaters - Natural gas heaters for gas pressure regulation stations - LNG and LPG vaporizers - Vaporizers and heaters for industrial gases - Process heaters - Gas heaters for analysis and laboratory application ATEX, IECEx, TR-CU and other international certificates

Request for a quote

Germany

Verified by Europages

With the very simple operation and the generated and saved measurement protocol, the documentation can be created quickly and completely reproduced. It is possible to save the measurement data in the device and to print it out again later. No tracer gas nor a second measuring device are required for use. The internal battery, the 230V charger or the 12V vehicle voltage can be used for the energy supply. All included in a complete set. Ethane is always contained in natural gas; evidence of this gas is also evidence of natural gas. A lengthy gas analysis is normally required to prove beyond any doubt that the measured gas concentration is actually natural gas and not swamp gas. This, also due to the sampling, a difficult and time- consuming process, is completely eliminated. Measurement and sampling directly at the borehole is easily possible. The printout can take place after the measurement.

Request for a quote

Germany

Verified by Europages

Process Characterization Software For The Transpector Gas Analysis System With one-click access to the two most popular RGA functions: monitor and leak check modes, FabGuard Explorer provides you with easy to interpret data showing the most frequently monitored gases (hydrogen, water vapor, nitrogen, oxygen, argon, etc.) in a convenient trend display. FabGuard Explorer is Windows® 8 ready, providing comprehensive RGA software with no concerns about operating system compatibility. The single-sensor version of FabGuard Explorer is a cost-effective solution to operating one Transpector ® RGA. With the software’s multi-sensor version, you can control multiple, different types of Transpector RGAs from a single computer. FabGuard Explorer allows for control of both Transpector MPH and Transpector 2 RGAs from the same software. For connecting multiple Transpector MPH sensors, INFICON offers routers and network switches, while the TCA485 Transpector Communications Adapter is used for...

Request for a quote

Belgium

Verified by Europages

Device Oriented Built as an operating system, the ALX solution is able to integrate any kind of devices: Cameras Environment analysis Gas detection Geiger counter Water analysis Thermography Device Oriented Because UAVs are more than remote control aircraft. HOME Device Oriented

Request for a quote

Liechtenstein, Principality of

Simplify and Accelerate Gas Analysis Micro GC Fusion offers significant throughput gain through rapid temperature ramping and modular architecture. The transportable, lightweight chassis and web-based user interface enables simplified operation for both on-site and in-lab gas analysis. Need application assistance? Click here! Need a Safety Data Sheet (formerly MSDS)? Click here! SO 2 and H 2S gas monitoring Permanent gases and olefins in refinery gas Impurities in petrochemical products and specialty gases Solvent/VOC gas monitoring Catalyst research for alternative energy

Request for a quote

Liechtenstein, Principality of

Process Characterization Software For The Transpector Gas Analysis System With one-click access to the two most popular RGA functions: monitor and leak check modes, FabGuard Explorer provides you with easy to interpret data showing the most frequently monitored gases (hydrogen, water vapor, nitrogen, oxygen, argon, etc.) in a convenient trend display. FabGuard Explorer is Windows® 8 ready, providing comprehensive RGA software with no concerns about operating system compatibility. The single-sensor version of FabGuard Explorer is a cost-effective solution to operating one Transpector ® RGA. With the software’s multi-sensor version, you can control multiple, different types of Transpector RGAs from a single computer. FabGuard Explorer allows for control of both Transpector MPH and Transpector 2 RGAs from the same software. For connecting multiple Transpector MPH sensors, INFICON offers routers and network switches, while the TCA485 Transpector Communications Adapter is used for...

Request for a quote

Russia

Application areas: - health care - drug discovery - pharmacy - environmental monitoring - forensic science - homeland security Technical performance: - patented design is a combination of a multifunctional sample introduction and ionization system, drift tube ion mobility spectrometer and sector TOF mass spectrometer with orthogonal acceleration - Multifunction sample introduction and ionization system works with both integrated ion sources and external available engineering solutions. Integrated ionization platform allows to use electrospray (ESI), atmosphere pressure chemical ionization (APCI), atmosphere pressure photoionization (APPI) - high resolution ion mobility spectrometer provides maximum selectivity compared to existing commercial instruments Main advantages: - allows to reach better sensitivity than approaches based on orthogonal acceleration reflectron TOF analyzers - allows to analyze gases and liquids much faster than liquid chromatography/mass spectrometry