• europages
  • >
  • COMPANIES - SUPPLIERS - SERVICE PROVIDERS
  • >
  • switch

Results for

Switch - Import export

FranceService Provider

France

Verified by Europages

Housing thermoplastic. Version: Operating principle: Magnetic. Rating: IP67. Note: If the actuator is within the switching range (safety door closed), the safety contacts and, if applicable, the signal contacts of the safety switch are activated. The contact is thus closed via a magnet (magnetic field). Form A: Actuator on one level to the safety switch. Form B: Actuator offset by 90° to the safety switch.

Request for a quote

France

Verified by Europages

Housing Form A plastic. Housing Form B die-cast zinc alloy. Active face POM. Housing Form C high-alloy stainless steel Version: Voltage: U = 10 – 30 V DC Function: Normally open Switch type: PNP Mounting type: flush Security type: IP 67 Note: Non-contact, functions wear-free with high switching frequency and accuracy. Non-sensitive to vibrations, dust and moisture. Inductive sensors record all metals without contact. Form C enables screw fastening in a T-slot. Is safe and saves space as the proximity switch lays flush in the slot. Short-circuit proof and reverse-polarity protected.

Request for a quote

France

Verified by Europages

Single-phase primary switched-mode power supply in metal housing. Note: Closed version with screw fittings with contact protection. Overload protection due to current limit, auto recovery. Protected against short-circuit, overload and surges. Power on LED indicator. For DIN top hat rail mounting. Technical data: Rating: IP00 Protection class: I Standard: UL508, TUV EN60950-1, CE Connection: screw terminals with contact protection Fastening: installation on DIN rail TS-35/7.5 or 15

Request for a quote

France

Verified by Europages

Housing, die-cast zinc. Housing cover, plastic, self-extinguishing. Hinge bolts, die-cast zinc/steel C45. Contacts, silver-nickel alloy 10. Note: The security hinge switches are used for monitoring the position of swing-hinged safety doors, protective hatches and hoods. The protective device is monitored directly in the hinge. By the universally pre-set versions, the switching angle is freely adjustable over the entire working range. A mounting aid ensures the quick alignment to doors and posts. The additional hinges have the same appearance and dimensions as the security hinge switches. The loading values given for the hinges are non-binding reference values without consideration of safety factors and exclude any liability. The values given are for information purposes only and do not constitute a legally binding assurance of properties.

Request for a quote

France

Verified by Europages

A switch disconnector ensures the interruption of current (under load) and the isolation of the load from the electrical supply. It provides optimal protection to users during machine maintenance as it can be locked with a padlock, preventing accidental startup during maintenance. Standard range: For 3P or 3P+N supply Ith 32 to 160A Available versions: In IP65 enclosure In enclosure with integrated fuse holder In cabinet bottom version (DIN rail mounting) with shaft (optional front plate) In panel mounting version (optional front plate)

Request for a quote

Do you sell or make similar products?

Sign up to europages and have your products listed

Add my business

France

Redundant low and high pressure control with channel synchronization Pressure control from 0.1b to 300b (to be defined when ordering) Vacuum control from -0.2b to -0.9b (to be defined when ordering) • Level of performance with AWAX controller: up to PL = e • Level of performance only: PL = c • Safety category with an external controller: up to 4 • 'Integrated security' level with an external controller: up to SIL 3 • Cycle before dangerous failure: B10d = 100,000 • Safety contacts: 2 x NO 2A/50V • Auxiliary contact: 1 x PNP NF 2A/50V • Reset: automatic • Attachment: 4 x M4 flat head or domed screws • Mounting position: 1 • Material: Polycarbonate • Electrical connection: PUR UL20549 very durable 50 cm cord with M12 connector • Pneumatic connection: G1/4 and 8 mm quick connector • Water resistance: IP 65 • Ambient temperature: -25°C to +60°C • Fluid temperature: -40°C to 140°C (specify temperature and the nature of the fluid in the order) • Marking: label + serial no. for traceability

Request for a quote

France

Safety management in 2 zones in a compact 45 mm format Short-circuit detection in 2 µs, self-resetting Removable terminals Performance level with AWAX controller: PL = e Safety category: 4 Safety Integrity Level: SIL 3 Time before dangerous failure: MTTFd = 415 years Cycle before dangerous failure: B10d=100,000 at 5A Risk duration: 20 ms max. Cable severing protection: yes (opening of safety lines) Short-circuit and overload protection: yes, using DLC (opening of safety lines and current limiting in contacts) Reaction 2 µs ultrafast Safety contacts/diagnostics zone 1: 3x NO 8A/250V redundant / 1x NF 8A/250V redundant series Safety contacts/diagnostics zone 2: 3x NO 8A/250V redundant / 1x NF 8A/250V redundant series Indicators: 2 display LEDs per zone for diagnostics and 1 LED for power Reset: configurable by dip-switch (SR=Automatic, N=manual) Mounting: symmetrical DIN 35mm rail on DIN 50022 Mounting: IP 54 electrical box Electrical connection: Maximum 14 AWG (2.08 mm²) / 250V minimum Temperature: -20°C to +60°C Certification: TÜV Rheinland 01/205/5168/11

Request for a quote

France

Safety management on 9 outputs in a compact 45mm housing Short-circuit detection in 2 µs, self-resetting Removable terminals Performance level with AWAX controller: PL = e Safety category: 4 Safety Integrity Level: SIL 3 Time before dangerous failure: MTTFd = 75 years Cycle before dangerous failure: B10d=100,000 at 5A Risk duration: 20 ms max. Cable severing protection: yes (opening of safety lines) Short-circuit and overload protection: yes, using DLC (opening of safety lines and current limiting in contacts) Reaction 2 µs ultrafast Safety contacts/diagnostics: 3x NO 8A/250V redundant / 1x NF 8A/250V redundant in serial (XXL version) or parallel (XXLP version) Indicators: 3 LEDs for diagnostics Reset: configurable by dip-switch (SR=Automatic, N=manual) Mounting: symmetrical DIN 35mm rail on DIN 50022 Mounting: IP 54 electrical box Electrical connection: Maximum 14 AWG (2.08 mm²) / 250V minimum Temperature: -20°C to +60°C Certification: TÜV Rheinland 01/205/5168/11

Request for a quote

France

Safety management with 85~265 VAC power Short-circuit detection in 2 µs, self-resetting Removable terminals Performance level with AWAX controller: PL = e Safety category: 4 Safety Integrity Level: SIL 3 Time before dangerous failure: MTTFd = 415 years Cycle before dangerous failure: B10d=100,000 at 5A Risk duration: 20 ms max. Cable severing protection: yes (opening of safety lines) Short-circuit and overload protection: yes, using DLC (opening of safety lines and current limiting in contacts) Reaction 2 µs ultrafast Safety contacts/diagnostics: 3x NO 8A/250V redundant / 1x NF 8A/250V parallel redundant Indicators: 3 LEDs for diagnostics Reset: configurable by dip-switch (SR=Automatic, N=manual) Mounting: symmetrical DIN 35mm rail on DIN 50022 Mounting: IP 54 electrical box Electrical connection: Maximum 14 AWG (2.08 mm²) / 250V minimum Temperature: -20°C to +60°C

Request for a quote

France

Compact 22.5 mm format Six Class A EN 50205 power contacts Removable terminals Cycle before dangerous failure: B10d=100,000 at 5A Max. closing time for NO contact: < 15ms (rebounds included) Duration of rebounds for NO contact: < 4ms Max. closing time for NF contact: < 16ms (rebounds included) Duration of rebounds for NF contact: < 13ms Protection severing wires: yes (opening of NO contacts) Safety contacts: 4x NO 8A/250V / 2x NF 8A/250V Indicators: 2 LEDs Reset: automatic Mounting: symmetrical DIN 35mm rail on DIN 50022 Mounting: IP 54 electrical box Electrical connection: Maximum 14 AWG (2.08 mm²) / 250V minimum Temperature: -20°C to +60°C

Request for a quote