• europages
  • >
  • COMPANIES - SUPPLIERS - SERVICE PROVIDERS
  • >
  • sensor control

Results for

Sensor control - Import export

FranceService Provider

France

Verified by Europages

RM2M offers a range of level sensors for liquids and solids. Rotary level sensors for solids: For high temperature, food processing, corrosive, or ATEX environments. Capacitive level sensors for solids: With power supply of 115-230VAC, 24-48VAC, or 24VDC. Membrane level sensors for solids: Operate with the pressure of the material on the membrane. Doesn't require a power supply. Pendular level sensors for solids: Simple and reliable sensor for powders forming a cone in the silo. Does not require a power supply. Conductive level sensors for liquids: Level sensor capable of controlling up to two levels. Available with the following power supplies: 115-230VAC, 24-48VAC, 24VDC. Floating level sensors for liquids: These models do not require an electrical power supply. Versions for agressive environments and food processing.

Request for a quote

France

Safety management in 2 zones in a compact 45 mm format Short-circuit detection in 2 µs, self-resetting Removable terminals Performance level with AWAX controller: PL = e Safety category: 4 Safety Integrity Level: SIL 3 Time before dangerous failure: MTTFd = 415 years Cycle before dangerous failure: B10d=100,000 at 5A Risk duration: 20 ms max. Cable severing protection: yes (opening of safety lines) Short-circuit and overload protection: yes, using DLC (opening of safety lines and current limiting in contacts) Reaction 2 µs ultrafast Safety contacts/diagnostics zone 1: 3x NO 8A/250V redundant / 1x NF 8A/250V redundant series Safety contacts/diagnostics zone 2: 3x NO 8A/250V redundant / 1x NF 8A/250V redundant series Indicators: 2 display LEDs per zone for diagnostics and 1 LED for power Reset: configurable by dip-switch (SR=Automatic, N=manual) Mounting: symmetrical DIN 35mm rail on DIN 50022 Mounting: IP 54 electrical box Electrical connection: Maximum 14 AWG (2.08 mm²) / 250V minimum Temperature: -20°C to +60°C Certification: TÜV Rheinland 01/205/5168/11

Request for a quote

France

Safety management on 9 outputs in a compact 45mm housing Short-circuit detection in 2 µs, self-resetting Removable terminals Performance level with AWAX controller: PL = e Safety category: 4 Safety Integrity Level: SIL 3 Time before dangerous failure: MTTFd = 75 years Cycle before dangerous failure: B10d=100,000 at 5A Risk duration: 20 ms max. Cable severing protection: yes (opening of safety lines) Short-circuit and overload protection: yes, using DLC (opening of safety lines and current limiting in contacts) Reaction 2 µs ultrafast Safety contacts/diagnostics: 3x NO 8A/250V redundant / 1x NF 8A/250V redundant in serial (XXL version) or parallel (XXLP version) Indicators: 3 LEDs for diagnostics Reset: configurable by dip-switch (SR=Automatic, N=manual) Mounting: symmetrical DIN 35mm rail on DIN 50022 Mounting: IP 54 electrical box Electrical connection: Maximum 14 AWG (2.08 mm²) / 250V minimum Temperature: -20°C to +60°C Certification: TÜV Rheinland 01/205/5168/11

Request for a quote

France

Safety management with 85~265 VAC power Short-circuit detection in 2 µs, self-resetting Removable terminals Performance level with AWAX controller: PL = e Safety category: 4 Safety Integrity Level: SIL 3 Time before dangerous failure: MTTFd = 415 years Cycle before dangerous failure: B10d=100,000 at 5A Risk duration: 20 ms max. Cable severing protection: yes (opening of safety lines) Short-circuit and overload protection: yes, using DLC (opening of safety lines and current limiting in contacts) Reaction 2 µs ultrafast Safety contacts/diagnostics: 3x NO 8A/250V redundant / 1x NF 8A/250V parallel redundant Indicators: 3 LEDs for diagnostics Reset: configurable by dip-switch (SR=Automatic, N=manual) Mounting: symmetrical DIN 35mm rail on DIN 50022 Mounting: IP 54 electrical box Electrical connection: Maximum 14 AWG (2.08 mm²) / 250V minimum Temperature: -20°C to +60°C

Request for a quote

France

Atex and machine safety management in a compact 45 mm format Atex dual-channel insulation barrier and controller for built-in machinery safety Atex safety ATEX standards EN 60079-0 EN 60079-11 EN 60079-25 EN 60079-26 ATEX marking [Ex ia] IIC Ga [Ex ia] IIIC Da II(1)GD Product used in combination with the "ANATOM78S- (PL or OX)-EEX" sensor Machine Safety Performance level with AWAX controller: PL = e in accordance with ISO 13849-1 Safety category: 4 in accordance with ISO 13849-1 Time before dangerous failure: MTTFd = 120 years Cycle before dangerous failure: B10d=100,000 at 5A Risk duration: 20 ms max. Cable severing protection: yes (opening of safety lines) Short-circuit protection and overload protection: yes (system shutdown). Requires return to a service workshop for a total control and troubleshooting. Safety contacts/diagnostics: 3x NO 8A/250V redundant / 1x NF 8A/250V redundant parallel Indicators: 3 LEDs Reset: configurable by dip-switch (SR=Automatic, N=manual) Mounting: symmetrical DIN 35mm rail on DIN 50022 Mounting: IP 54 electrical box Electrical connection: Maximum 14 AWG (2.08 mm²) / 250V minimum Temperature: -20°C to +40°C. Certification: INERIS 06ATEX0007X

Request for a quote

Do you sell or make similar products?

Sign up to europages and have your products listed

Add my business
Filters

Results for

Sensor control - Import export

Number of results

5 Products

Company type

Category