• europages
  • >
  • COMPANIES - SUPPLIERS - SERVICE PROVIDERS
  • >
  • safety locks

Results for

Safety locks - Import export

FranceService Provider

France

No power or under-voltage locking on machine casings Machine protection closing control for harsh environments Antimicrobial handle available Level of performance with AWAX controller: up to PL = e Safety category: up to 4 with AWAX controller or PLC SIL 3 Time before dangerous failure: MTTFd = 100 years Maximum detection activation distance: 2 mm Holding force: up to 936 N (ref. version + OX-R) or up to 820 N (ref. version + OX-E) Safety contacts/diagnostics: 2 x NO 400mA max/24V redundant and 1 x PNP 250mA Detection encoding: mono-code inviolable Reset: automatic or controlled (ref. + OP) Housing mount: 4 tamper-proof M6 screws (optional ref: BH6) Handle attachment: 2 M8 screws Mounting position: 1 Casing material: 316L stainless steel mirror polished (OX version) Suction cup material: Magnetic INOX (ref. + OX) Electrical Connection: 50cm PUR cord with M12 connector Water resistance: IP 67/68 Temperature: -25°C to +50°C (thermal protection for suction cups in case of overheating due to a persistent command) Marking: laser engraving with mechanically punched serial number for permanent traceability

Request for a quote

France

No power or under-voltage locking on machine casings Machine protection closing control for harsh environments 100% stainless steel version available Level of performance with AWAX controller: up to PL = e Safety category: up to 4 with AWAX controller or PLC SIL 3 Time before dangerous failure: MTTFd = 100 years Maximum detection activation distance: 2 mm Holding force: up to 580 N Safety contacts/diagnostics: 2 x NO 400mA max/24V redundant and 1 x PNP 250mA Detection encoding: mono-code inviolable Indicator: LED Reset: automatic or controlled (ref. + OP) Attachment: 4 M4 screws (inviolable on new generation and optional ref.: BH4) Mounting position: 1 Casing material: INOX316L mirror polished (OX version) or POLYCARBONATE (PL version) Suction cup material: INOX (SM1 + OX) or steel (SM1 + PL-AC) Electrical connection: the M12 metal base will be replaced with a 50cm PUR cord with an M12 connector on the new generation Water resistance: IP 67/68 Temperature: -25°C to +50°C. Marking: laser engraving with mechanically punched serial number for permanent traceability (OX version) or screen printed serial number for traceability (PL version)

Request for a quote

France

Contactless "door lock" encoded detection Unlock command with just one contact during serialization of products • Cycle before dangerous failure: B10d = 1,000,000 at 200mA • Bolt travel: 9 mm • Bolt diameter: 12 mm • Shearing strength: 1000 N • Distance between latch and lock: 0 to 4 mm (adjustable when assembling, recommended to 4 mm) • Maximum lateral displacement between strike and lock: +/- 0.8 mm • Maximum angular displacement between strike and lock: +/- 5° • Safety locking contacts: 2 x NO 0.4A /24V redundant and • Unlock command: PLC-compatible (12~30 VDC/2~5 mA) • Diagnostic error: Auxiliary output indicates unlocking • Reset: on command • Infinite automatic offset control when connected in series: minimal consumption • Auxiliary release: key supplied (free key in lock mode; captive key in release mode) • Attachment: 4 M4 screws (screw covers included) • Mounting position: 1 • Material: PA6 fiberglass reinforced • Electrical connection: very resistant 50 cm or 130 cm PUR UL20549 cord with M12 connector or cable (contact us) • Water resistance: IP 65 • Ambient temperature: -5°C to +40°C. • Marking: screen printed + serial no. for traceability

Request for a quote

France

Contactless "door lock" encoded detection Contactless "door open / closed" detection Unlock command with just one contact during serialization of products Emergency evacuation handle • Level of performance with AWAX controller: up to PL = e Safety category with an external controller: up to 4 • Cycle before dangerous failure: B10d = 1,000,000 • Bolt travel: 14 mm • Bolt diameter: 24 mm (beveled for "under-voltage" closed position or "lock" mode) • Shearing strength: 2000 N • Gap between strike and lock: 2 to 4 mm (adjustable when assembling, recommended to 4 mm) Maximum lateral offset between strike and lock: +/- 2.5 mm • Maximum angular displacement between strike and lock: +/- 5° • Safety locking contacts: 2 x NO 2A/50V • Safety door contacts: 2 x PNP/500 mA • Unlock command: PLC-compatible (12~30 VDC/2~5 mA) • Fault Diagnosis: bolt stuck, power out of specification, temperature out of specification, electromagnet failure, serialization failure • Reset: on command • "SMART consumption" for minimal power consumption when connected in series • Auxiliary release: female triangle key 8 mm x 14.2 mm (optional) • Attachment: 4 M6 screws (screw covers supplied, screws not included) • Mounting position: 2 (door pulling, door pushing) • Material: PA6 fiberglass reinforced • Electrical connection: very resistant 50 cm PUR UL20549 cord with M23 connector or cable (contact us) • Water resistance: IP 65 • Operating temperature: -15°C to +45°C • Marking: screen printed + serial no. for traceability • Reference for evacuation handle: AT

Request for a quote

France

Grade : 304 Wire diameter: 1,04 mm Ref : 13014 Product : Canister Lenght: 68 meters Weight: 454 gr

Request for a quote

Do you sell or make similar products?

Sign up to europages and have your products listed

Add my business

France

Grade : 304 Wire diameter: 0,63 mm Ref : 13006 Product : Canister Lenght: 185 meters Weight: 454 gr

Request for a quote

France

Grade : 304 Wire diameter: 0,51 mm Ref : 13005 Product : Canister Lenght: 280 meters Weight: 454 gr

Request for a quote
Filters

Results for

Safety locks - Import export

Number of results

8 Products

Company type

Category