The angle bracket enables easy mounting of the clamping elements directly on the machine component. The bore D2 serves to hold the clamping element. The clamping element can be mounted on the front or rear of the bracket. The bores D3 enable the bracket to used for other applications.

Request for a quote

France

Verified by Europages

Sold in pairs. Fastening material included. Note As an option for floor, platform or side mounting.

Request for a quote

France

Verified by Europages

Hook clamps and clamping screw carbon steel, tempered.

Request for a quote

France

Verified by Europages

Mounting plate steel/plastic. Monitor bracket aluminium. Bearing washers and sleeves plastic. Mounting flange aluminium. Mounting adapter aluminium. Screws steel. Version: Mounting plate painted. Monitor bracket painted. Mounting flange painted. Mounting adapter painted. Screws electro zinc-plated

Request for a quote

France

Verified by Europages

Indexing plungers are used where it is necessary to prevent changes of position due to lateral forces. A new locking position can be set only after the plunger has been manually disengaged. With this indexing plunger a cam lever is used to retract the pin. The indexing plunger remains unlocked as long as the handle is positioned over the dead-centre of the cam. The ergonomic cam lever enables light handling with low effort. Temperature range: Permanent operating temperature acc. to IEC 216 max. 160°C. Short-term operating temperature max. 250°C. Advantages: Simple and quick operation. Suitable for high temperature applications. With integrated detent function. On request: Special versions. Accessory: Spacer rings 03089 Positioning bushes for indexing plunger 03099-50 Mounting brackets 03099

Request for a quote

Do you sell or make similar products?

Sign up to europages and have your products listed

Add my business

France

20 N integrated handle magnetic door holding High temperature and silicone cable Contactless coded electronic sensor Level of performance with AWAX controller: up to PL = e Safety category: up to 4 with an AWAX controller Time before dangerous failure: MTTFd = 100 years Max. activation distance: 3 mm, 1 mm hysteresis Holding Force: transmitter + receiver in contact = 20N Safety contacts/diagnostics: 2 x NO 0.8A/24V redundant and 1 x PNP 250mA Detection encoding: mono-code inviolable Reset: automatic Housing mount: 4 tamper-proof M4 screws (optional ref: BH4) Handle assembly: M8 screw (optional handle) Mounting position: 2 (double wall brackets) Material: INOX 316L mirror polished Electrical connection: 50cm Ultra-soft silicone cord with M12 connector. Water resistance: IP 69K Extreme temperature: -40°C to +125°C Marking: laser engraving with mechanical punching of the serial number for permanent traceability

Request for a quote

France

High temperature, magnetic door holding, integrated 20N Contactless coded electronic sensor Total safety management with an AWAX controller Level of performance with AWAX controller: up to PL = e Safety category: up to 4 with an AWAX controller Time before dangerous failure: MTTFd = 100 years Max. activation distance: 3 mm, 1 mm hysteresis Holding Force: transmitter + receiver in contact = 20N Safety contacts/diagnostics: 2 x NO 0.8A/24V redundant and 1 x PNP 250mA Detection encoding: mono-code inviolable Reset: automatic Attachment: 4 tamper-proof M4 screws (optional ref: BH4) Mounting position: 2 (double wall brackets) Material: INOX 316L mirror polished Electrical connection: 50cm Ultra-soft silicone cord with M12 connector. Water resistance: IP 69K Extreme temperature: -40°C to +125°C Marking: laser engraving with mechanical punching of the serial number for permanent traceability

Request for a quote

France

RFID sensor with 16 million codes Category 3 total security management without an external controller Programmable code through auto-learning (no software or PC) Level of performance with AWAX controller: up to PL = e Safety category without an external controller: 3 (EN 954-1) Cycle after dangerous failure: B10d = 2000000 at 2 Amps Max activation distance: up to 24 mm Security contact/diagnostics: 2 x redundant NO 2A/48V and 1 x 400mA PNP auxiliary Detection encoding: inviolable multicode Indicator: LED indicates code recognition Reset: automatic Attachment: 4 tamper-proof M4 screws (in base option: BH4) Mounting position: 2 (double wall brackets) Material: PA6 Electrical Connection: 3, 6, 12m cable (UL2464 PVC) or 50cm PUR cable with M12 connector (base + MKT) Sealing: IP 67 Temperature: -20 °C to +60 °C Marking: pad printing + serial number for traceability

Request for a quote

France

RFID sensor with 16 million codes Suitable for metallic environments Programmable code through auto-learning (no software or PC) Max activation distance: up to 24 mm Security contact/diagnostics: 2 x 400mA and 1 x 200mA auxiliary PNP Detection encoding: inviolable multicode Indicator: LED indicates code recognition Reset: automatic Attachment: 4 tamper-proof M4 screws (in base option: BH4) Mounting position: 2 (double wall brackets) Material: PA6 Electrical Connection: 50cm PUR cable with M12 connector Sealing: IP 67 Standing room temperature: -25 °C to +70 °C. Storage temperature: -40 °C to +85 °C Marking: pad printing + serial number for traceability

Request for a quote

France

Contactless coded electronic sensor Total safety management with an AWAX controller Low cost solution for multi-access applications • Level of performance with AWAX controller: up to PL = e • Safety category: up to 4 with an AWAX controller • Time before dangerous failure: MTTFd = 334 years • Max. activation distance: 10 mm, 2 mm hysteresis • Safety contacts/diagnostics: 2 x NO 0.8A max / redundant 24V / 1xcontact PNP 250mA • Detection encoding: mono-code inviolable • Indicator: LED indicates code recognition • Reset: automatic • Attachment: 4 tamper-proof M4 screws (optional ref: BH4) • Mounting position: 78S-98S, 78SMKT, 78SMKT130 versions: 2 (double wall brackets) • Mounting position: 78SM12 and 98SM12 versions: 1 • Material: 78S-98S, 78SMKT, 78SMKT130: PA6 or INOX316L (ANATOM78S-OX or ANATOM78S-OX-MKT) • Matierial for 78SM12, 78SESM12 and 98SM12 : polycarbonate (PC) • Electrical Connection: 3, 6, 12m cable (78S/98S) or 50cm cord with M12 connector (ref. + MKT) or 130cm cord with M12 connector (ref. + MKT130) or M12 metal (ref. + M12) • Water resistance: IP 67/68 (PA6, PC) or IP 69K with stainless steel - new generation • Temperature: -25°C to +60°C • Marking: PA6 pad printing + serial no., PC pad printing + serial no., INOX316L laser engraving with mechanically punched serial no. for permanent traceability • Certification: UL 508 / C22.2 no.14 C-UL-US listed 34CB (file E214209) (Not applicable for versions MKT and M12)

Request for a quote

France

Contactless encoded electronic sensor with relay Category 3 total safety management without an external controller 12V version for embedded applications Level of performance without an external controller: PL = c Level of performance with AWAX controller: up to PL = e Safety category without an external controller: 1 Cycle before dangerous failure: B10d = 2,000,000 at 50mA Max. activation distance: 10 mm, 2 mm hysteresis Safety contacts: 2 x NO 250 mA/48V redundant Detection encoding: mono-code inviolable Indicator: LED indicates code recognition Reset: automatic Attachment: 4 tamper-proof M3 screws (optional ref: BH3) Mounting position: 2 (double wall brackets) Material: PA6 Electrical Connection: 3, 6, 12m cable (UL2464 PVC) Water resistance: IP 67/68 Temperature: -20°C to +60°C Marking: pad printing + serial no. for traceability

Request for a quote