• europages
  • >
  • COMPANIES - SUPPLIERS - SERVICE PROVIDERS
  • >
  • sensors

Results for

Sensors - Import export

France

France

Verified by Europages

The AirSafe PM provides continuous and precise monitoring of dust exposures in indoor ambient air. The AirSafe PM can be used for indoor workplace exposure monitoring, utilizing the high range and low range sensors to detect and track particulate exposure limits and limit violations. Health and safety personnel can use the measurement data to provide a safe working environment and report site air quality.

Request for a quote

France

Verified by Europages

Continuous mass flow measurement of all types of dust, powder and granules in free fall and pneumatic conveying. Microwave sensor for on-line mass flow measurement of solids up to 20 t/h.

Request for a quote

France

Verified by Europages

Paddy has been developed to supply a trending information of pulverization. It measures changes in particle size for instance to detect screen breaks. Paddy is insensitive against contaminations and works without a bypass.

Request for a quote

France

Verified by Europages

RM2M offers a range of level sensors for liquids and solids. Rotary level sensors for solids: For high temperature, food processing, corrosive, or ATEX environments. Capacitive level sensors for solids: With power supply of 115-230VAC, 24-48VAC, or 24VDC. Membrane level sensors for solids: Operate with the pressure of the material on the membrane. Doesn't require a power supply. Pendular level sensors for solids: Simple and reliable sensor for powders forming a cone in the silo. Does not require a power supply. Conductive level sensors for liquids: Level sensor capable of controlling up to two levels. Available with the following power supplies: 115-230VAC, 24-48VAC, 24VDC. Floating level sensors for liquids: These models do not require an electrical power supply. Versions for agressive environments and food processing.

Request for a quote

France

Verified by Europages

Housing aluminium. Cable sheath PVC. Version Compact sensor and plug design. Flat connector, 8pole, 1x pin. Connection cable, 6wire, ø 3.55–0.3 mm. Cable bend radius, > 17 mm (static). Note Works with magnetic tapes 21725. The reading distance between the sensor and tape must be 0.1 to 2 mm. The sensor is supplied with operating voltage and draws current via the electronics. System accuracy, repeat accuracy and travel speed is dependent on the electronics. Plugin connection to position indicators 21700 and 21702. Technical data Rating IP 67; EN 60529 (sensor head) Shock resistance 2000 m/s², 11 ms; EN 60068227 Vibration resistance 200 m/s², 50 Hz–2 kHz; EN 6006826 Temperature range Ambient temperature 0…60°C Storage temperature 10…70°C Assembly Installation must be carried out using the enclosed user information. A, reading distance sensor/tape ≤ 2 mm B, lateral offset ± 2 mm C, misalignment ± 3° D, pitch gradient ± 1° E, lateral gradient ± 3°

Request for a quote

France

Verified by Europages

The Cairsens© O2 + NO3 sensor allows specific pollutant measurement comparable to reference methods.

Request for a quote

France

Verified by Europages

The Cairsens© NH3 micro-sensor allows specific pollutant measurement comparable to reference methods.

Request for a quote

France

Verified by Europages

The tension meter is used to perform a pretension test on commercially available belt systems quickly and easily by means of frequency measurement. Fully electronic and equipped with stateoftheart microprocessor technology, the meter enables precise adjustment of all V, toothed and flat belts that have to be tensioned in the range from 10 to 600 Hz. The measurement must never be performed while the drive is running The meter is not permitted or certified for use in potentially explosive areas.

Request for a quote

France

Verified by Europages

Housing polyamide 6. Hollow shaft steel. Screen plastic. Grub screw steel. Version Impactresistant housing. Hollow shaft black oxidised. Grub screw black. Dial black, digits white. Note Position indicators allow direct reading of input measurement values at a glance. In addition, the value indicated per spindle rotation (corresponding spindle pitch) can be selected and the various indicator values are realised by a transmission gear. The position indicators are distinguished by their small construction with very clear display. They are especially suitable for small spindle distances and small shaft diameters and have a torque support that is positioned in a hole on the side. ** At the 1st asterisk give assembly position and at the 2nd asterisk give the count direction (see sample order “assembly position, count direction”). Technical data – Counter consisting of 3 10position dials – Height of figures about 4 mm – Hollow shaft Ø 10 H7 mm

Request for a quote

France

Verified by Europages

The Cairsens© sensor allows specific pollutant measurement comparable to reference methods.

Request for a quote

France

Verified by Europages

The Cairsens© NH3 micro-sensor allows specific pollutant measurement comparable to reference methods.

Request for a quote

France

Verified by Europages

The Cairsens© CO sensor allows specific pollutant measurement comparable to reference methods.

Request for a quote

France

Verified by Europages

The Cairsens© NO2 sensor allows specific pollutant measurement comparable to reference methods.

Request for a quote

France

Verified by Europages

Magnetic tape, magnetised plastic sheet. Carrier band steel. Cover band stainless steel. Version Scale with incremented coding. Pole length 5 mm. Note Simple adhesive mounting; selfassembly possible. Required tape length calculated from measuring path + sensor length "L" + (2 x run or return "B"). L = see drawing of sensor used. B = 10 mm (run and return). Technical data Coefficient of expansion (11 ± 1) x 106/K (spring steel) Temperature range Ambient temperature 20–70°C Storage temperature 40–70°C Assembly Installation using the preaffixed doublesided adhesive tape must be carried out according to the enclosed user information. On request Other lengths from 0.1–100 m, in increments of 0.1 m. Note Relative humidity 100%. Dewing is permissible. Drawing reference 1) Cover band A = 0.176 mm 2) Magnetic tape M = 1.0 mm 3) Carrier band T = 0.3 mm 4) Adhesive tape K = 0.1 mm 5) Required tape length = measuring path + L + 2 x B 6) Measuring path

Request for a quote

France

Verified by Europages

The thermocouple probe is characterized by a fast response time and is perfectly suited for high or very high temperature operation. The temperature sensor is often delivered with a connection head (see photo opposite).

Request for a quote

France

LED Ceiling Lighting Sensor 16W Body Polycarbonate body Cover PC opal cover with protech UV LED SMD LED with high color rendering (Ra≥80) with a minimum lifetime of 50,000 hours (L70-85°C) Driver RF sensor with 360 ° detection angle

France

Capture system for chips suction, with pneumatic automatic up and down control. Subject to the machine configuration / chosen options. Online sales on Meca-line site here

Request for a quote

Do you sell or make similar products?

Sign up to europages and have your products listed

Add my business