Results for
France
USE : Measure the rail temperature, with tables for rail joints. ( SNCF Type) Length 18, 24 and 36 m (for expansion devices : Charts) ADVANTAGES : Simple and accurate device. SNCF Type - Ref. 38 - Aluminium Rectangular Body - Scaled from -20° C to +60° C - Length = 150 mm - Weight = 200 gr Thermometer into a piece of rail - Ref. 39 with Handle and Cover Plate - Length of rail = 170 mm - Weight = 7 Kg This Device enables users to find out the True Temperature inside the Rail. Circle Thermometer with Ring - Ref. 38-R - Body in Brass - Ø 10 mm - Length 154 mm - Graduations from -20° C to +65° C - Weight = 45 gr. OPTIONS : Thermometer Ref. 38 into a Wooden Case (16 x 4 x 3 cm) - Ref. 38-CO Thermometer Ref. 38 with Protective Leather Casing - Ref. 38-E Thermometer Ref. 38 with 2 Sticked Magnets (to attach to the rail) - Ref. 38-A
Request for a quoteFrance
USE : High-Precision Rule to measure the Switches and Crossings (New Equipment or Maintenance) ADVANTAGES : - Direct reading for all Measurements - Integrated adjustable bubble Level. 1 - This SW-9182 Rule is accurate for the following direct readings and measurements : * Track gauge (-10 to +40 mm) * Superelevation of the Track (-40 to +200 mm) * Track Guide (-10 to +10 mm) * Between Guard Rails (1332 to 1365 mm for Standard Gauge) * Width of Switches Opening (31 to 60 mm) - Size of Switch Tongue Protection. * Accuracy of reading : 1 mm * Size (for Standard Gauge) : 1710 x 105 x 250 mm * Weight = 3.6 Kg (1435 mm Track) ( We can supply for all Gauges) All Rules are electrically insulated. 3 - Rule for checking 1/2 Point and Crossings Ref. 582 with 3 mm Checking Punch "Duralium" . Body Nylon insulator on base - Length 1.65 m - Weight 1.7 Kg OPTIONS : - Wooden Case 175 x 14 x 28 cm (Weight 13 Kg) - Ref. CO - Adaptation Device for Tramway Track - Add Ref. TR - Square at 60 ° to contro
Request for a quoteFrance
USE : High-precision measure ro check the Track Gauge and superelevation (during Repair and Maintenance Work) ADVANTAGES : Lightweight (aluminium body) - Integrated adjustable Buble Level. * Standard GW-80 Track Gauge Rule is very accurate forthe following direct readings and measurements : - Track gauge reading = -10 at + 40 mm - Track Superelevation reading = -40 to +200 mm - Reading Accuracy = 1 mm - Net Weight = 2.9 Kg (for 1435 mm Track Gauge) - Sizes = 1680 x 105 x 300 mm - Electrically insulated (We can supply for all Gauges). * GW-85 "A longside Platform " Rule checks the positioning of the track in relation of the platform. OPTIONS : - Adaptation Device for Tramway Gauge : Add - Ref. TR - Wooden Case = 13 Kg (175 x 14 x 28 cm) - Ref. CO * 1NG "SNCF" type Rule - Duraluminium Body - High Accuracy - Weight = 3 Kg * 11NG Single Standard Rule for Gauge Measure (Economical Gauge), Steel Body - Weight 2 Kg
Request for a quoteFrance
USE : Check the distance between wheels (setting), Inner Side of the Axles. ADVANTAGES : Simple, accurate and durable Device. - Steel Body (painted yellow) - End Section in treated steel, interchangeable - With integrated Meter - Measurement Capacity : - for Standard Gauge 1350 to 1390 mm - Ref. RW-N - for metric Gauge 900 to 970 mm - Ref. RW-E - Direct Read Measurement Indicator - Chrome Rotating Part - Net Weight : 3 Kg (Standard Gauge) - 2.3 kg (Metric Gauge) - Delivered in Iriko Varnish Wooden Case with fasteners and handle. (The Gauge Measure is placed on a Foam Cushion in the box) - "SNCF" agreed
Request for a quoteFrance
USE : Measure lengths of Track by travelling on the rail. ADVANTAGES : Simple, tough and accurate device (Can be folded for easy transportation) - Portable Device with a Base Stand - Ref. OD-10 - Ø 320 mm. Rubber Wheel - 2 lateral rail Roller Guides - 1 Folding Handle Length unfolded : 1.10 m. - 1 meter from 0 to 9999 m with re-zero setting - Floor sizes with handle folded : 53 x 17 x 32 cm - Weight = 3 Kg OPTIONS : - Odometer on to the PLATFORM TROLLEY - Add the Ref. as : PL1S + OD-10 - Base Stand Device for Odometer - Ref. SO-1
Request for a quoteFrance
USE : Check the superelevation of the track - Various inspections and levelling tasks. ADVANTAGES : Durable and accurate. - Steel Base - Ref. 7 - Length = 20 cm - Flask protected by an unbreakable rhodhoïd - Weight = 0.2 Kg OPTIONS : - Aluminium Base Weight = 0.1 Kg - Ref. 71 - Steel Level with magnets - Ref. 7-AM
Request for a quoteFrance
USE : Checking and measuring of Rail Deflation. ADVANTAGES : Easy and accurate Tool. - Body in steel - Brass graduated scale from 0 to 50 mm. - Galvanized or treated with bichromates for protection - Dimensions of support base = 14 x 16 cm. - with Handle - Net Weight = 1 Kg - Reference : 307
Request for a quoteFrance
USE : Instrument for instantly Rail corrugation. ADVANTAGES : A very lightweight, accurate and easy to handle Device. - Aluminium Alloy Body- Ref. PAC-280 - Longitudinal Measuring Stroke = 280 mm - Vertical Measuring Stroke = 3 mm - Accuracy = 1/100th mm - Net Weight = 1.6 Kg - The Device is attached to the top of the Rail-Head using 2 magnets. - The user reads the rail corrugation on the scale dial placed above the Device. OPTIONS : - Longititudinal Stroke 500 mm (Net Weight = 2.7 Kg) - Ref. PAC-500 - Other stroke on request
Request for a quoteFrance
USE : Check and measure Wear of the rail. ADVANTAGES : Accurate Device. Slide Callipers Rule - Ref. 1019 - All Steel Construction - Scaled from de 0 to 180 mm - Delivered in Wooden Case - Total Length = 310 mm - Width of Jaws = 70 mm - Weights : - Slide Calliper Rule = 0.75 Kg / Wooden Case = 0.50 Kg Astride Calliper - Ref. 1020 - It is laid on top of the rail to measure vertical and lateral Wear - Stainless Steel - Special Device for each rail section - Weight = 1.4 Kg With Level Control of Inclination of the rail - Ref. 1022 - (at 1/20 or at 1/40) - Weight 1.3 Kg OPTIONS : Calliper for measuring the wear of interior of rail - Ref. 1021
Request for a quoteFrance
USE : Check the Torque of the coachscrews, the Fishbolts and the Rail-Bolts. ADVANTAGES : Very accurate and reliable. - Measurement Capacity 16 - 80 daN/m - Total Length = 1.18 m - Net Weight = 4.2 Kg - Square Bit Drive = 19.05 mm - Delivered in Wooden Case ( Weight with Case = 6.2 Kg ) - Reference : CDY * Sockets with 19.05 mm Square Bit Drive - See the Supply Accessories Panel.
Request for a quoteFrance
USE : Various Inspections and measurements (Controls) ADVANTAGES : Simple and tough Portable POUGET TEST - NABLA (French Clips) - Ref. PTN Used to measure the curvature of the NABLA Clip on the track after tightening. - Measurement Stroke = 10 mm - Measurement accuracy = 1/10th mm - Delivered with wooden Case for easy transport = 30 x 30 x 10 cm - Weight of the Device in the Case = 4 Kg . GAUGE for inspecting the play of the Fishplate Joints - Ref. 580 - Scaled 1 - 20 mm - Cadmium plated for protection - Length = 230 mm - Weight = 0.25 Kg GAUGE for inspecting the tightness of Clips, " RN" (French Clips) - Ref. 579-1 - Angled Model - Scaled 0.3 to 5 mm - Length = 150 mm. - Weight = 60 g. CALLIPERS for inspecting the half-open position of the Switches, SNCF Model - Ref. 585 - 5/6/8 mm. Wedges - Length = 140 mm - Aperture = 20.5 mm - Weight = 0.17 Kg GAUGE 3 points in steel for NABLA Clips - Ref. G3P - Weight = 0.3 Kg (Normal Tightening = 1.3 mm) GAUGE 3 points (double - mini / maxi
Request for a quoteFrance
Continuous particulate monitoring for saturated wet stack applications typically found after wet scrubbers, wet electrostatic precipitators and wet flue gas desulphurisation plants.
Request for a quoteFrance
Filter dust approved particulate monitoring system for low dust concentrations from dry industrial processes.
Request for a quoteFrance
Eco-designed, ultra-compact, smart & connected continuous gas analyzer, for emission or process gas monitoring. Perfectly suited to control SO2 removal efficiency in processes using Flue-gas desulfurization FGD / DeSOx systems.
Request for a quoteFrance
CLD based gas monitor for the measurement of NO, NO2 and NOx in the range 0-4000 µg/m³, based on 100/200 dilution rate.
Request for a quoteFrance
QAL1 and MCERTS approved particulate CEM providing high quality emission measurement for dust concentrations from industrial processes.
Request for a quoteFrance
PM10, PM2.5 and PM1 fine dust concentration measurement in the range 0-10,000 μg/m3 according the ISO 10473 Standard. QAL 1 certified and US EPA approved.
Request for a quoteDo you sell or make similar products?
Sign up to europages and have your products listed
France
QAL1 approved particulate CEM for opacity monitoring from combustion stacks.
Request for a quoteFrance
Continuous emission monitor providing high quality emission measurement for low dust concentrations from dry industrial processes.
Request for a quoteFrance
The SM-3 mercury analyzer measures continuously the elemental, bound and ionic mercury in stack fluegas.
Request for a quoteFrance
The VOC72M’s metrology, in accordance with EN 14662-3 (2005) & EN 15267-1 (2009) standard for benzene measurement, is based on gas chromatography (GC) coupled with a photo-ionization detector (PID).
Request for a quoteFrance
The VM-3000 Mercury Vapor Monitor measures continuously the Hg concentration in air and other gases.
Request for a quoteFrance
Very small, ultra-light, with on-board GPS, data logger, battery pack and color TFT display for very comfortable and easy mercury monitoring in ambient air and other gases.
Request for a quoteFrance
Measuring of Total Gaseous Mercury (TGM) in air and other gases. Reliable for measurements at ultra-trace levels (sub-ng/m³) according to EN 15852 .
Request for a quoteFrance
The Natural Gas Sampling System 3000 is designed for very fast conditioning of samples from a pressurized natural gas source.
Request for a quoteFrance
The MC-3000 generates a continuous stream of a mercury vapor loaded gas in order to check or calibrate mercury analyzers.
Request for a quoteFrance
This accessory is meant for manually calibrating the UT-3000 Mercury Ultratracer.
Request for a quoteResults for
Measurement and control - Import exportNumber of results
80 ProductsCountries
Company type