Results for
France
MCERTS QAL1 approved, stand alone or multisensor particulate CEM providing high quality emission measurement for low dust concentrations from dry industrial processes. • ProScatter™ backscatter sensor technology with superior minimum detection <1mg/m³ • certified to 15 mg/m³ for processes with low typical emissions limits • manual and remote zero and span checks available to ensure optimal instrument performance and to comply with EN 13284/QAL1 • automatic functionality check • purge flow fail sensor option with inbuilt automatic optical shield activation • flue gas blocker option to protect plant engineers from harmful flue gases during maintenance
Request for a quoteFrance
The DM 170 is designed to comply with the TÜV suitability testing scheme to EN 15267 and for measuring dust concentrations in a wide range of industrial applications. Due to its wide dynamic range, the DM 170 may be used in combustion applications as well as in higher dust loading applications (such as power, cement and metals smelting, and in processes without filtration). Its simplicity and wide operating range makes it also ideally suited for process optimisation applications. • ProScatter™ backscatter sensor technology • Manual and remote Zero and Span checks available to ensure optimal instrument performance • purge flow fail sensor and optical shield options • nonintrusive system designed to operate in noncondensing stack environments • Singleside stack installation reduces contamination risk
Request for a quoteFrance
Especially designed for continuous measurement of velocity of solids and particles such as granulates, powders and dusts, which are transported in free fall or in pneumatic transport. Uses triboelectric correlation technology. • plugin sensor for easy retrofit • continuous speed measurement of solids • measurement directly in the conveying stream • material independent measurement
Request for a quoteFrance
Microwave sensor for continuous moisture measurement in dry bulk solids and installation on conveyor belts, screw feeder or hoppers. Microwave based sensor for high resolution and accuracy. • highly resistant to abrasion • integrated temperature reading • flow detection function • moisture ranges 0 65 % • measurement accuracy 0.1 % • ATEXcertified
Request for a quoteFrance
Sensor for continuous moisture measurement in dry bulk solids and installation on conveyor belts, screw feeder or hoppers. Microwave based sensor for high resolution and accuracy. • highly resistant to abrasion • extended measurement range, up to 85 % moisture • high temperature version up to 190 °C • measurement accuracy 0.1 % • recording of surface moisture and capillary moisture
Request for a quoteFrance
Continuous solids mass flow measurement in densestream conveying and high levels of throughput. Designed to measure solid flows during pneumatic dense phase transport. The sensor measures density and speed. • unlimited throughput volumes can be measured • no wear thanks to the ceramic inner pipe • simple retrofitting • maintenancefree
Request for a quoteFrance
Continuous flow measurement of powder or granules in high pressure densephase conveying. Designed to measure solid flows during pneumatic dense phase transport. The sensor measures density and speed. • pressureresistant up to 64 bar • maintenancefree • contactless • ATEX category 3 approved
Request for a quoteFrance
Continuous velocity measurement in tube version for careful material transport. Measures in full crosssection. • continuous speed measurement of solids in metal pipes • measurement directly in the conveying stream/entrained flow • measurement completely independent of material • sensor is made accordingly to the existing pipe diameter • measurement without product contact
Request for a quoteFrance
Actor in the field of instrumentation, Deltafluid offers measurement products in pyrometry. Our range includes thermometers to obtain direct indications of temperature but also temperature sensors (resistance probe, thermocouple, multi-point probe, pyrometer assembly ...) which can be coupled with transmitters.
Request for a quoteFrance
LAS 5000XD uses Tunable Diode Laser Spectroscopy (TDLS) and comes in various models for measuring parameters such as NH3 + H2O, HF, CO + CO2, O2, HCl + H2O, etc. It combines robustness, fast response time (1 s) and high accuracy measurement in harsh environments.
Request for a quoteFrance
The LCPD BOX is a full extractive sampling probe assembly which extracts the sample gas through a probe & heated filter to remove particulates.
Request for a quoteFrance
The HOFI™ BOX offers an exclusive sampling system dedicated to heated analyzers. Ideal for corrosive gases.
Request for a quoteFrance
Rack 3U monitor using the TDL extractive technology to measure online the NH3 pre and/or post catalyst: SCR (Selective Catalytic Reduction) or SNCR (Selective Non-Catalytic Reduction)
Request for a quoteFrance
Cairnet® device is a real-time standalone and networkable air-monitoring station including up to six Cairsens® microsensors. It is powered by solar panels and offers cellular communication.
Request for a quoteFrance
LED based, UV photometric ozone analyzer providing accurate, stable and repeatable O3 measurements in the range of 0-500 ppb or 0-10 ppm.
Request for a quoteFrance
LED based, UV photometric ozone analyzer providing accurate, stable and repeatable O3 measurements in the range of 0-500 ppb or 0-10 ppm.
Request for a quoteFrance
Continuous particulate monitoring for saturated wet stack applications typically found after wet scrubbers, wet electrostatic precipitators and wet flue gas desulphurisation plants.
Request for a quoteDo you sell or make similar products?
Sign up to europages and have your products listed
France
PM10, PM2.5 and PM1 fine dust concentration measurement in the range 0-10,000 μg/m3 according the ISO 10473 Standard. QAL 1 certified and US EPA approved.
Request for a quoteFrance
The VOC72M’s metrology, in accordance with EN 14662-3 (2005) & EN 15267-1 (2009) standard for benzene measurement, is based on gas chromatography (GC) coupled with a photo-ionization detector (PID).
Request for a quoteFrance
The VM-3000 Mercury Vapor Monitor measures continuously the Hg concentration in air and other gases.
Request for a quoteFrance
Very small, ultra-light, with on-board GPS, data logger, battery pack and color TFT display for very comfortable and easy mercury monitoring in ambient air and other gases.
Request for a quoteFrance
Measuring of Total Gaseous Mercury (TGM) in air and other gases. Reliable for measurements at ultra-trace levels (sub-ng/m³) according to EN 15852 .
Request for a quoteFrance
CLD based gas monitor offering superior performances for the measurement of NO, NO2 and NOx criteria pollutants in the range 0-1 ppm or 0-10 ppm. Optional NH3 monitoring.
Request for a quoteFrance
UV Fluorescence gas monitor offering excellent performances for the monitoring of SO2 in the range 0-10 ppm or 0-1 ppm. Option: H2S / TRS monitoring.
Request for a quoteFrance
Gas monitor for fast, precise, direct and continuous measurement of NO2 concentrations in the range 0-1000 ppb.
Request for a quoteFrance
Non Dispersive Infra Red Carbon Monoxide Analyzer for CO measurements in the range 0-50ppm. CO2 monitoring as option.
Request for a quoteFrance
The dry extractive SEC™ system dries the gas sample at the sampling point, eliminating the necessity of an expensive heated sampling line.
Request for a quoteFrance
Ideal for mid-high to high concentrations, also for sampling locations in hazardous areas (ATEX).
Request for a quoteResults for
Measurements - Import exportNumber of results
147 ProductsCountries
Company type
Category