Contactless encoded electronic sensor with relay Category 3 total safety management without an external controller 12V version for embedded applications Level of performance without an external controller: PL = c Level of performance with AWAX controller: up to PL = e Safety category without an external controller: 1 Cycle before dangerous failure: B10d = 2,000,000 at 50mA Max. activation distance: 10 mm, 2 mm hysteresis Safety contacts: 2 x NO 250 mA/48V redundant Detection encoding: mono-code inviolable Indicator: LED indicates code recognition Reset: automatic Attachment: 4 tamper-proof M3 screws (optional ref: BH3) Mounting position: 2 (double wall brackets) Material: PA6 Electrical Connection: 3, 6, 12m cable (UL2464 PVC) Water resistance: IP 67/68 Temperature: -20°C to +60°C Marking: pad printing + serial no. for traceability

Request for a quote

France

Manages person entry in hazard zones using an electrical locking key Contactless encoded electronic sensor with relay Category 3 total safety management without an external controller Electrical locking key with position contact Level of performance without an external controller: PL = d Level of performance with AWAX controller: up to PL = e Safety category without an external controller: 3 Safety Integrity Level: SIL 2 Cycle before dangerous failure: B10d = 2,000,000 at 2A Max. activation distance: 10 mm, 2 mm hysteresis Safety contacts/diagnostics: 2 x NO 2A/48V redundant / 2xPNP 250mA auxiliary (open/closed door and locking/unlocking of contacts) Detection encoding: mono-code inviolable Note: two-color LED indicates the key locking position; white LED indicates code recognition Reset: automatic Attachment: 4 tamper-proof M4 screws (optional ref: BH4) Mounting position: 2 (double wall brackets) Material: Polycarbonate Electrical connection: M12 metal base Water resistance: IP 65 Temperature: -15°C to +60°C Marking: screen printed + serial no. for traceability

Request for a quote

France

40N integrated stainless steel magnetic door holding Contactless encoded electronic sensor with relay Category 3 total safety management without an external controller Level of performance without an external controller: PL = d Level of performance with AWAX controller: up to PL = e Safety category without an external controller: 3 Safety Integrity Level: SIL 2 Cycle before dangerous failure: B10d = 2,000,000 at 2A Max. activation distance: 4 mm, 2 mm hysteresis Holding Force: transmitter + receiver in contact = 40N Safety contacts/diagnostics: 2 x NO 2A/48V redundant / 1 x PNP 250mA encoding detection: single inviolable code Reset: automatic Attachment: 4 tamper-proof M4 screws (optional ref: BH4) Mounting position: 1 Material: INOX 316L mirror polished Electrical connection: 3, 6, 12m cable Water resistance: IP 67/68 Temperature: -25°C to +60°C Marking: INOX316L laser engraving with mechanical punching of the serial number for permanent traceability Certification: TÜV Rheinland 01/205/5238/12 License Test Mark 968/EL 214.01/12

Request for a quote

France

Contactless encoded electronic sensor with relay Category 3 total safety management without an external controller Level of performance without an external controller: PL = c Level of performance with AWAX controller: up to PL = e Safety category without an external controller: 1 Cycle before dangerous failure: B10d = 2,000,000 at 100mA Max. activation distance: 6 mm, 2 mm hysteresis Safety contacts/diagnostics: 2 x NO 1A/48V redundant / 1 x PNP 1A auxiliary Detection encoding: mono-code inviolable Indication: LED indicating code absence Reset: automatic Attachment: 2 M30 nuts provided Mounting position: 1 Material: CuNi Electrical connection: 3, 6, 12m cable Water resistance: IP 67 Temperature: -25°C to +60°C Marking: label + serial no. for traceability

Request for a quote

France

Contactless encoded electronic sensor with relay Up to 8 zone differentiation codes Safety contacts 2A / 250V • Level of performance without an external controller: PL = c • Level of performance with AWAX controller: up to PL = e • Safety category without an external controller: 1 • Cycle before dangerous failure: B10d = 2,000,000 at 2A • Max. activation distance 3SSR24V/5SSR24BX/5SSR24BX-US: 8 mm, 2 mm hysteresis • Max. activation distance 2SSR24V/2SSR24BX: 4 mm, 2 mm hysteresis • Safety contacts/diagnostics 3SSR24V: 1 x NO 2A/250V / 1 x NF 2A/250V auxiliary • Security contacts/diagnostics 5SSR24BX and 5SSR24BX-US: 2 x NO 2A/250V / 1 x PNP NF 250mA auxiliary (24V) • Security contacts 2SSR24V: 2 x NO 2A/250V • Security contacts 2SSR24BX: 1 x NO 2A/250V and 1 x NF 2A/250V • Detection encoding 3SSR24V, 5SSR24BX/5SSR24BX-US: single inviolable code • Detection encoding 2SSR24V and 2SSR24BX: 8 inviolable codes • Indicators 2SSR24V, 2SSR24BX, 3SSR24V and 5SSR24BX: Red LED indicating code absence (not transmitter) • Indicator 5SSR24BX-US: Two-color red/green LED • Reset: automatic • Attachment: 4 tamper-proof M4 screws (optional ref: BH4) • Mounting position: 2 (double wall brackets) • Matierial PA6: 2SSR24V, 2SSR24BX, 3SSR24V, 5SSR24BX, 5SSR24BX-MKT and 5SSR24BX-US • Material INOX 316L mirror polished: 5SSR24BX-OX and 5SSR24BX-OX-MKT • Electrical Connection: 3, 6, 12m cable or 50cm cord with M12 connector (UL20549 PUR) for5SSR24BX-OX and 5SSR24BX-OX-MKT • Water resistance: IP 67/68 (PA6) or IP 69Kwith stainless steel - new generation • Temperature: -25°C to +60°C • Marking: PA6 pad printing + serial number, INOX316L laser engraving with mechanically punched serial number for permanent traceability

Request for a quote

Do you sell or make similar products?

Sign up to europages and have your products listed

Add my business

France

Contactless encoded electronic sensor with relay Category 3 total safety management without an external controller 12V version for embedded applications Level of performance without an external controller: PL = d Level of performance with AWAX controller: up to PL = e Safety category without an external controller: 3 Safety Integrity Level: SIL 2 Cycle after dangerous failure: B10d = 2,000,000 at 2A Max. activation distance: 10 mm, 2 mm hysteresis Security contacts / diagnostics AMX5 / AMX5CM12: 2 x NO 2A / 48V redundant / 1 x PNP 250mA auxiliary Security contacts AMX4: 2 x NO 2A/48V redundant Security contacts / diagnostics AMX3: 1xNO 2A / 48V redundant (2 series contacts) / 1xNF 250mA auxiliary Detection encoding: mono-code inviolable Indicator: LED indicates code recognition Reset: automatic Attachment: 4 tamper-proof M4 screws (optional ref: BH4) Mounting position: 2 (double wall brackets) Material: PA6 or INOX 316L mirror polished (AMX3-OX/AMX5-OX ⇥or PC (AMX5CM12) Electrical Connection: 3, 6, 12m (UL2464 PVC) or 50cm cable with M12 connector (UL20549 PUR) (ref + MKT) or M12 metal base (AMX5CM12) Water resistance: IP 67/68 (PA6 / PC) or IP 69K with stainless steel - new generation Temperature: -25°C to +60°C Marking: PA6 pad printing + serial number, INOX316L laser engraving with mechanically punched serial number for permanent traceability Certification: TÜV Rheinland 01/205/5238/12 License Test Mark 968/EL 214.01/12 UL 508 / C22.2 no.14 C-UL-US listed 34CB (file E214209)

Request for a quote
Filters

Results for

Electronic relays - Import export

Number of results

7 Products

Category