Rolling stock, integrated manufacturing and testing equipment, the mobility of our trade specialists are just some of the key assets we deploy to comprehensively manage your requirements, whatever your needs or the time of year. At the same time, we also perform maintenance operations on your equipment at your premises: safety compliance, refurbishment and repair, welding, metal work, electrical and mechanical maintenance, assembly and retrofitting. Our qualified employees are at your disposal and are fully accustomed to working on site with customers, whether independently or with teams working in other trades. Our teams have all the necessary clearances and qualifications to provide you with quality facilities, while working in compliance with safety regulations and your internal procedures.

Request for a quote

France

Manages person entry in hazard zones using an electrical locking key Contactless encoded electronic sensor with relay Category 3 total safety management without an external controller Electrical locking key with position contact Level of performance without an external controller: PL = d Level of performance with AWAX controller: up to PL = e Safety category without an external controller: 3 Safety Integrity Level: SIL 2 Cycle before dangerous failure: B10d = 2,000,000 at 2A Max. activation distance: 10 mm, 2 mm hysteresis Safety contacts/diagnostics: 2 x NO 2A/48V redundant / 2xPNP 250mA auxiliary (open/closed door and locking/unlocking of contacts) Detection encoding: mono-code inviolable Note: two-color LED indicates the key locking position; white LED indicates code recognition Reset: automatic Attachment: 4 tamper-proof M4 screws (optional ref: BH4) Mounting position: 2 (double wall brackets) Material: Polycarbonate Electrical connection: M12 metal base Water resistance: IP 65 Temperature: -15°C to +60°C Marking: screen printed + serial no. for traceability

Request for a quote

France

No power or under-voltage locking on machine casings Machine protection closing control for harsh environments 100% stainless steel version available Level of performance with AWAX controller: up to PL = e Safety category: up to 4 with AWAX controller or PLC SIL 3 Time before dangerous failure: MTTFd = 100 years Maximum detection activation distance: 2 mm Holding force: up to 580 N Safety contacts/diagnostics: 2 x NO 400mA max/24V redundant and 1 x PNP 250mA Detection encoding: mono-code inviolable Indicator: LED Reset: automatic or controlled (ref. + OP) Attachment: 4 M4 screws (inviolable on new generation and optional ref.: BH4) Mounting position: 1 Casing material: INOX316L mirror polished (OX version) or POLYCARBONATE (PL version) Suction cup material: INOX (SM1 + OX) or steel (SM1 + PL-AC) Electrical connection: the M12 metal base will be replaced with a 50cm PUR cord with an M12 connector on the new generation Water resistance: IP 67/68 Temperature: -25°C to +50°C. Marking: laser engraving with mechanically punched serial number for permanent traceability (OX version) or screen printed serial number for traceability (PL version)

Request for a quote

France

Contactless coded electronic sensor Total safety management with an AWAX controller Suitable for groove profiles and single or double doors Level of performance with AWAX controller: up to PL = e Safety category: up to 4 with an AWAX controller Time before dangerous failure: MTTFd = 334 years Max. activation distance: 10 mm, 2 mm hysteresis Safety contacts/diagnostics: 2 x NO 0.8A max/24V redundant / 1xNF (78S) or 1 x NO (98S) 250mA Detection encoding: mono-code inviolable Indicator: LED indicates code recognition Reset: automatic Attachment: 4 tamper-proof M4 screws (optional ref: BH4). Suitable for grooved profiles. Screw caps provided. Mounting position: 1 Material: Polycarbonate Electrical connection: 2 M12 metal bases for instant serial connection Water resistance: IP 67/68 Temperature: -25°C to +60°C Marking: screen printed + serial no. for traceability

Request for a quote

France

Contactless coded electronic sensor Total safety management with an AWAX controller Cylindrical M18 for "invisible" assembly Level of performance with AWAX controller: up to PL = e Safety category: up to 4 with an AWAX controller Time before dangerous failure: MTTFd = 100 years Max. activation distance: 6 mm, 2 mm hysteresis Safety contacts/diagnostics: 2 x NO 0.8A max/24V redundant / 1xcontact PNP 250mA Detection encoding: mono-code inviolable Reset: automatic Attachment: 2 M30 nuts provided Mounting position: 1 Material: CuNi Electrical connection: M12 metal base Water resistance: IP 67 Temperature: -20°C to +60°C Marking: label + serial no. for traceability

Request for a quote

Do you sell or make similar products?

Sign up to europages and have your products listed

Add my business

France

USE : Checking of the Sleepers Position when laying or replacing Sleepers. ADVANTAGES : Simple and Tough. Fixed Metallic Square Track Gauge (m) Dimensions (cm) Weight (Kg) Reference 1.44 162 x 115 7.3 390 1 120 x 100 5 390-M 1.52 170 x 115 7.5 390-R 1.676 190 x 115 8.7 390-G Folding Metallic Square - Ref. PL - Transporting Case - Ref. ET1 Reinforced Wooden Square (French Norm : N.F.F. 76019) Track Gauge (m) Dimensions (cm) Weight (Kg) Reference 1.44 162 x 112 3.1 391 1 120 x 100 2.7 391-M 1.52 170 x 112 3.3 391-R 1.676 190 x 115 3.6 391-G Folding Plastic Square - Ref. PVC For Track Gauge 1.44 m = 164 x 115 cm, Folded Position = 162 x 110 cm. Transporting Case Ref. ET2 = Ø 16 cm - Length 170 cm OPTIONS : - Electrically Insulated Metalli c Square (For Track Gauge : 1.44 m) - Ref. 390-1 - Alumium Metallic Square (Weight 4 Kg) - Ref. 390-A