ergonomic slabs which maintain worker comfort and which at the same time resist the passage of rolling machines and heavy loads interlocking slabs on 4 sides for flexible arrangement quick installation antifatigue function thanks to its lower surface consisting of «FlexPoints» supports up to 45 tonnes / m² easily separable and reconnectable panels to obtain a new configuration yellow safety angles and ramps available to secure and facilitate access to the slabs by users and rolling machines very good resistance to chemicals

Request for a quote

France

20 N integrated handle magnetic door holding High temperature and silicone cable Contactless coded electronic sensor Level of performance with AWAX controller: up to PL = e Safety category: up to 4 with an AWAX controller Time before dangerous failure: MTTFd = 100 years Max. activation distance: 3 mm, 1 mm hysteresis Holding Force: transmitter + receiver in contact = 20N Safety contacts/diagnostics: 2 x NO 0.8A/24V redundant and 1 x PNP 250mA Detection encoding: mono-code inviolable Reset: automatic Housing mount: 4 tamper-proof M4 screws (optional ref: BH4) Handle assembly: M8 screw (optional handle) Mounting position: 2 (double wall brackets) Material: INOX 316L mirror polished Electrical connection: 50cm Ultra-soft silicone cord with M12 connector. Water resistance: IP 69K Extreme temperature: -40°C to +125°C Marking: laser engraving with mechanical punching of the serial number for permanent traceability

Request for a quote

France

40N integrated stainless steel magnetic door holding Contactless coded electronic sensor Total safety management with an AWAX controller Level of performance with AWAX controller: up to PL = e Safety category: up to 4 with an AWAX controller Time before dangerous failure: MTTFd = 360 years Max. activation distance: 3 mm, 2 mm hysteresis Holding Force: transmitter + receiver in contact = 40N Safety contacts/diagnostics: 2 x NO 0.8A max / 48V redundant and 1 x PNP 250mA Detection encoding: mono-code inviolable Reset: automatic Attachment: 4 tamper-proof M4 screws (optional ref: BH4) Mounting position: 1 Material: INOX 316L mirror polished Electrical Connection: 3, 6, 12m cable or 50cm cord PUR M12 (ref. + MKT) Water resistance: IP 67/68 (EPINUS-4K-MKT) and IP 69K (EPINUS-4K/SES) Temperature: -25°C to +70°C. Marking: laser engraving with mechanical punching of the serial number for permanent traceability

Request for a quote

France

Contactless coded electronic sensor Total safety management with an AWAX controller High temperature Level of performance with AWAX controller: up to PL = e Safety category: up to 4 with an AWAX controller Time before dangerous failure: MTTFd = 100 years Max. activation distance: 7 mm, 1 mm hysteresis, rotation ± 30° Safety contacts/diagnostics: 2 x NO 1A max/24V redundant and 1 x PNP 1A auxiliary Detection encoding: mono-code inviolable Reset: automatic Attachment: 2 central M4 screws not included; anti-rotation lugs provided Mounting position: 1 Material: INOX 316L mirror polished Electrical connection: 50cm Ultra-soft silicone cord with M12 connector. Water resistance: IP 69K Operating temperature: -30°C to +110°C. Peak temperature: -40°C to +130°C Marking: laser engraving with mechanical punching of the serial number for permanent traceability

Request for a quote

France

Contactless coded electronic sensor Total safety management with an AWAX controller High temperature Level of performance with AWAX controller: up to PL = e Safety category: up to 4 with an AWAX controller Time before dangerous failure: MTTFd = 100 years Max. activation distance: 7 mm, 1 mm hysteresis, rotation ± 30° Safety contacts/diagnostics: 2 x NO 1A/24V redundant and 1 x PNP 1A auxiliary Detection encoding: mono-code inviolable Reset: automatic Attachment: 2 M4 screws not included; anti-rotation lugs provided Mounting position: 1 (4 x paste on screw-caps provided) Material: INOX 316L mirror polished Electrical connection: 50cm Ultra-soft silicone cord with M12 connector. Water resistance: IP 69K Temperature: -30°C to +110°C. Marking: laser engraving with mechanical punching of the serial number for permanent traceability

Request for a quote

Do you sell or make similar products?

Sign up to europages and have your products listed

Add my business

France

40N integrated stainless steel magnetic door holding Contactless encoded electronic sensor with relay Category 3 total safety management without an external controller Level of performance without an external controller: PL = d Level of performance with AWAX controller: up to PL = e Safety category without an external controller: 3 Safety Integrity Level: SIL 2 Cycle before dangerous failure: B10d = 2,000,000 at 2A Max. activation distance: 4 mm, 2 mm hysteresis Holding Force: transmitter + receiver in contact = 40N Safety contacts/diagnostics: 2 x NO 2A/48V redundant / 1 x PNP 250mA encoding detection: single inviolable code Reset: automatic Attachment: 4 tamper-proof M4 screws (optional ref: BH4) Mounting position: 1 Material: INOX 316L mirror polished Electrical connection: 3, 6, 12m cable Water resistance: IP 67/68 Temperature: -25°C to +60°C Marking: INOX316L laser engraving with mechanical punching of the serial number for permanent traceability Certification: TÜV Rheinland 01/205/5238/12 License Test Mark 968/EL 214.01/12

Request for a quote
Filters

Results for

Dangers - Import export

Number of results

7 Products