• europages
  • >
  • COMPANIES - SUPPLIERS - SERVICE PROVIDERS
  • >
  • stops

Results for

Stops - Import export

FranceBordeaux and Aquitaine

France

Safety management in a compact 22.5 mm format Mono or two-channel with wiring. "Low consumption" Inputs Removable terminals Performance level with AWAX controller: PL = d Safety category: 3 (two-channel) Safety Integrity Level: SIL 2 Time before dangerous failure: MTTFd = 240 years Cycle before dangerous failure: B10d=100,000 at 5A Risk duration: 20 ms max. Cable severing protection: yes (opening of safety lines) Safety contacts/diagnostics: 2x NO 8A/250V redundant / 1x NF 8A/250V parallel redundant + 1x NO static 400 mA Indicators: 3 LEDs for diagnostics Reset: configurable by dip-switch (SR=Automatic, N=manual) Mounting: symmetrical DIN 35mm rail on DIN 50022 Mounting: IP 54 electrical box Electrical connection: Maximum 14 AWG (2.08 mm²) / 250V minimum Temperature: -20°C to +60°C

Request for a quote

France

Safety management in 2 zones in a compact 45 mm format Short-circuit detection in 2 µs, self-resetting Removable terminals Performance level with AWAX controller: PL = e Safety category: 4 Safety Integrity Level: SIL 3 Time before dangerous failure: MTTFd = 415 years Cycle before dangerous failure: B10d=100,000 at 5A Risk duration: 20 ms max. Cable severing protection: yes (opening of safety lines) Short-circuit and overload protection: yes, using DLC (opening of safety lines and current limiting in contacts) Reaction 2 µs ultrafast Safety contacts/diagnostics zone 1: 3x NO 8A/250V redundant / 1x NF 8A/250V redundant series Safety contacts/diagnostics zone 2: 3x NO 8A/250V redundant / 1x NF 8A/250V redundant series Indicators: 2 display LEDs per zone for diagnostics and 1 LED for power Reset: configurable by dip-switch (SR=Automatic, N=manual) Mounting: symmetrical DIN 35mm rail on DIN 50022 Mounting: IP 54 electrical box Electrical connection: Maximum 14 AWG (2.08 mm²) / 250V minimum Temperature: -20°C to +60°C Certification: TÜV Rheinland 01/205/5168/11

Request for a quote

France

Safety management on 9 outputs in a compact 45mm housing Short-circuit detection in 2 µs, self-resetting Removable terminals Performance level with AWAX controller: PL = e Safety category: 4 Safety Integrity Level: SIL 3 Time before dangerous failure: MTTFd = 75 years Cycle before dangerous failure: B10d=100,000 at 5A Risk duration: 20 ms max. Cable severing protection: yes (opening of safety lines) Short-circuit and overload protection: yes, using DLC (opening of safety lines and current limiting in contacts) Reaction 2 µs ultrafast Safety contacts/diagnostics: 3x NO 8A/250V redundant / 1x NF 8A/250V redundant in serial (XXL version) or parallel (XXLP version) Indicators: 3 LEDs for diagnostics Reset: configurable by dip-switch (SR=Automatic, N=manual) Mounting: symmetrical DIN 35mm rail on DIN 50022 Mounting: IP 54 electrical box Electrical connection: Maximum 14 AWG (2.08 mm²) / 250V minimum Temperature: -20°C to +60°C Certification: TÜV Rheinland 01/205/5168/11

Request for a quote

France

Safety management with 85~265 VAC power Short-circuit detection in 2 µs, self-resetting Removable terminals Performance level with AWAX controller: PL = e Safety category: 4 Safety Integrity Level: SIL 3 Time before dangerous failure: MTTFd = 415 years Cycle before dangerous failure: B10d=100,000 at 5A Risk duration: 20 ms max. Cable severing protection: yes (opening of safety lines) Short-circuit and overload protection: yes, using DLC (opening of safety lines and current limiting in contacts) Reaction 2 µs ultrafast Safety contacts/diagnostics: 3x NO 8A/250V redundant / 1x NF 8A/250V parallel redundant Indicators: 3 LEDs for diagnostics Reset: configurable by dip-switch (SR=Automatic, N=manual) Mounting: symmetrical DIN 35mm rail on DIN 50022 Mounting: IP 54 electrical box Electrical connection: Maximum 14 AWG (2.08 mm²) / 250V minimum Temperature: -20°C to +60°C

Request for a quote

France

Activation by contact, wide range of detectable material Great ease of detection anywhere on the button Bistable function with timed lock release • Service life before dangerous failure: 40 years • Activation distance: on contact • Electrical contact: 2 PNP NF 200mA (NO powered off) • Detection of short circuit in the wires: yes • Detection of abnormal function: yes • Indication mode "on": solid red LED ring • Indication mode "off": flashing red LED ring ▪ Indication mode "error": timed offset red LED ring ◦ Trim color: red Opal green color enables lighting of the ring ◦ Attachment: 51mm bore and 2 to 6 D3 invisible screws (not included) ◦ Very low visible thickness ▪ Mounting position: 1 • Material TR90UV • Food contact: yes • Resistance to washing: yes • Anti-vandalism: yes with the new 2015 generation • Electrical connection: 1.5mm² screwless connector without • Water resistance: IP 67 with peripheral silicone seal • Temperature: -25°C to +60°C • Printing: screen printing for the reference on the back of the product

Request for a quote