40N integrated stainless steel magnetic door holding Contactless encoded electronic sensor with relay Category 3 total safety management without an external controller Level of performance without an external controller: PL = d Level of performance with AWAX controller: up to PL = e Safety category without an external controller: 3 Safety Integrity Level: SIL 2 Cycle before dangerous failure: B10d = 2,000,000 at 2A Max. activation distance: 4 mm, 2 mm hysteresis Holding Force: transmitter + receiver in contact = 40N Safety contacts/diagnostics: 2 x NO 2A/48V redundant / 1 x PNP 250mA encoding detection: single inviolable code Reset: automatic Attachment: 4 tamper-proof M4 screws (optional ref: BH4) Mounting position: 1 Material: INOX 316L mirror polished Electrical connection: 3, 6, 12m cable Water resistance: IP 67/68 Temperature: -25°C to +60°C Marking: INOX316L laser engraving with mechanical punching of the serial number for permanent traceability Certification: TÜV Rheinland 01/205/5238/12 License Test Mark 968/EL 214.01/12

Request for a quote

France

Contactless encoded electronic sensor with relay Category 3 total safety management without an external controller Suitable for groove profiles and single or double doors Level of performance without an external controller: PL = d Level of performance with AWAX controller: up to PL = e Safety category without an external controller: 3 Safety Integrity Level: SIL 2 Cycle before dangerous failure: B10d = 2,000,000 at 2A Max. activation distance: 8 mm, 3 mm hysteresis Safety contacts/diagnostics: 2 x NO 2A/48V redundant / 1 x PNP 250mA (X5) or 1xNF (X5.2) auxiliary Detection encoding: mono-code inviolable Indicator: LED indicates code recognition Reset: automatic (SR version) or Manual (AR version) Attachment: 4 tamper-proof M4 screws (optional ref: BH4). Suitable for grooved profiles. Screw caps provided. Mounting position: 1 Material: Polycarbonate Electrical connection: 1 M12 connector (X5 version) or 2 M12 connectors (X5.2 version for instant serial connection) Water resistance: IP 67/68 Temperature: -25°C to +60°C Marking: screen printed + serial no. for traceability Certification: TÜV Rheinland 01/205/5238/12 License Test Mark 968/EL 214.01/12

Request for a quote

France

Contactless encoded electronic sensor with relay Category 3 total safety management without an external controller 12V version for embedded applications Level of performance without an external controller: PL = d Level of performance with AWAX controller: up to PL = e Safety category without an external controller: 3 Safety Integrity Level: SIL 2 Cycle after dangerous failure: B10d = 2,000,000 at 2A Max. activation distance: 10 mm, 2 mm hysteresis Security contacts / diagnostics AMX5 / AMX5CM12: 2 x NO 2A / 48V redundant / 1 x PNP 250mA auxiliary Security contacts AMX4: 2 x NO 2A/48V redundant Security contacts / diagnostics AMX3: 1xNO 2A / 48V redundant (2 series contacts) / 1xNF 250mA auxiliary Detection encoding: mono-code inviolable Indicator: LED indicates code recognition Reset: automatic Attachment: 4 tamper-proof M4 screws (optional ref: BH4) Mounting position: 2 (double wall brackets) Material: PA6 or INOX 316L mirror polished (AMX3-OX/AMX5-OX ⇥or PC (AMX5CM12) Electrical Connection: 3, 6, 12m (UL2464 PVC) or 50cm cable with M12 connector (UL20549 PUR) (ref + MKT) or M12 metal base (AMX5CM12) Water resistance: IP 67/68 (PA6 / PC) or IP 69K with stainless steel - new generation Temperature: -25°C to +60°C Marking: PA6 pad printing + serial number, INOX316L laser engraving with mechanically punched serial number for permanent traceability Certification: TÜV Rheinland 01/205/5238/12 License Test Mark 968/EL 214.01/12 UL 508 / C22.2 no.14 C-UL-US listed 34CB (file E214209)

Request for a quote

France

Dynamic detection of approaching hand even wearing gloves Fraud reduction system and MSD reduction Capacitive and optical technology touch button Performance level with COM3C controller: PL = e Safety category with COM3C: IIIC (EN 574), 4 (ISO 13849-1) 'Failsafe' level with COM3C: SIL 3 Time before dangerous failure: MTTFd = 100 years Activation distance: on touch (0 force = MSD reduction) Safety contacts: 1 x PNP NO/50mA OSSD and 1 x PNP NF/50mA OSSD Diagnostics: fraud, simultaneity, short-circuiting of contacts with multi-function illuminated ring Reset: automatic with two buttons correctly activated Attachment: Attachment: 51mm bore and 2 to 6 invisible D3 screws (not included) Mounting position: 1 Material: TR90UV yellow Electrical connection: 6-way screwless push terminal 1.5mm² Water resistance: IP 67 with silicone seal on the trim Temperature: -25°C to +60°C Marking: screen printed + serial no. for traceability Recommendations: use gloves in accordance with EN 388

Request for a quote

France

Version for mechanical or touch buttons KOB101T Controls the position of the press Removable terminals Performance level with AWAX controller: PL = e Safety category: IIIC Safety Integrity Level: SIL 3 Time before dangerous failure: MTTFd = 60 years Cycle before dangerous failure: B10d=100,000 at 5A Risk duration: 20 ms max. Cable severing protection: yes (opening of safety lines) Safety contacts/diagnostics: 3x NO 8A/250V redundant / 1x NF 8A/250V parallel redundant Indicators: 3 LEDs for diagnostics Reset: automatic with simultaneity control at 400 ms Position control: high press position contact input Mounting: symmetrical DIN 35mm rail on DIN 50022 Mounting: IP 54 electrical box Electrical connection: Maximum 14 AWG (2.08 mm²) / 250V minimum Temperature: -20°C to +60°C Certification: INERIS 0080.5486.520.04.12.0059

Request for a quote

Do you sell or make similar products?

Sign up to europages and have your products listed

Add my business

France

Safety management in 2 zones in a compact 45 mm format Short-circuit detection in 2 µs, self-resetting Removable terminals Performance level with AWAX controller: PL = e Safety category: 4 Safety Integrity Level: SIL 3 Time before dangerous failure: MTTFd = 415 years Cycle before dangerous failure: B10d=100,000 at 5A Risk duration: 20 ms max. Cable severing protection: yes (opening of safety lines) Short-circuit and overload protection: yes, using DLC (opening of safety lines and current limiting in contacts) Reaction 2 µs ultrafast Safety contacts/diagnostics zone 1: 3x NO 8A/250V redundant / 1x NF 8A/250V redundant series Safety contacts/diagnostics zone 2: 3x NO 8A/250V redundant / 1x NF 8A/250V redundant series Indicators: 2 display LEDs per zone for diagnostics and 1 LED for power Reset: configurable by dip-switch (SR=Automatic, N=manual) Mounting: symmetrical DIN 35mm rail on DIN 50022 Mounting: IP 54 electrical box Electrical connection: Maximum 14 AWG (2.08 mm²) / 250V minimum Temperature: -20°C to +60°C Certification: TÜV Rheinland 01/205/5168/11

Request for a quote

France

Safety management on 9 outputs in a compact 45mm housing Short-circuit detection in 2 µs, self-resetting Removable terminals Performance level with AWAX controller: PL = e Safety category: 4 Safety Integrity Level: SIL 3 Time before dangerous failure: MTTFd = 75 years Cycle before dangerous failure: B10d=100,000 at 5A Risk duration: 20 ms max. Cable severing protection: yes (opening of safety lines) Short-circuit and overload protection: yes, using DLC (opening of safety lines and current limiting in contacts) Reaction 2 µs ultrafast Safety contacts/diagnostics: 3x NO 8A/250V redundant / 1x NF 8A/250V redundant in serial (XXL version) or parallel (XXLP version) Indicators: 3 LEDs for diagnostics Reset: configurable by dip-switch (SR=Automatic, N=manual) Mounting: symmetrical DIN 35mm rail on DIN 50022 Mounting: IP 54 electrical box Electrical connection: Maximum 14 AWG (2.08 mm²) / 250V minimum Temperature: -20°C to +60°C Certification: TÜV Rheinland 01/205/5168/11

Request for a quote

France

Safety management with 85~265 VAC power Short-circuit detection in 2 µs, self-resetting Removable terminals Performance level with AWAX controller: PL = e Safety category: 4 Safety Integrity Level: SIL 3 Time before dangerous failure: MTTFd = 415 years Cycle before dangerous failure: B10d=100,000 at 5A Risk duration: 20 ms max. Cable severing protection: yes (opening of safety lines) Short-circuit and overload protection: yes, using DLC (opening of safety lines and current limiting in contacts) Reaction 2 µs ultrafast Safety contacts/diagnostics: 3x NO 8A/250V redundant / 1x NF 8A/250V parallel redundant Indicators: 3 LEDs for diagnostics Reset: configurable by dip-switch (SR=Automatic, N=manual) Mounting: symmetrical DIN 35mm rail on DIN 50022 Mounting: IP 54 electrical box Electrical connection: Maximum 14 AWG (2.08 mm²) / 250V minimum Temperature: -20°C to +60°C

Request for a quote

France

Add 4 power safety lines at 8A/250V with a safety PLC or control box without loss of Safety Class Compact format 22.5 mm/removable terminals Level of performance: PL = e Safety category: 4 Safety Integrity Level: SIL 3 Cycle before dangerous failure: B10d=100,000 at 5A Risk duration: 20 ms max. Cable severing protection: yes (opening of safety lines) Safety contacts/diagnostics: 4x NO 8A/250V redundant / 1x NF redundant in series (test) and 8A/250V parallel (information) C4SX indicators: 2 LEDs C5SX indicators: 2 LEDs Reset: automatic Number of inputs: 1 (C4SX) and 2 (C5SX) Mounting: symmetrical DIN 35mm rail on DIN 50022 Mounting: IP 54 electrical box Electrical connection: Maximum 14 AWG (2.08 mm²) / 250V minimum Temperature: -20°C to +60°C

Request for a quote

France

Compact 45 mm format Two position key switch: free and captive Removable terminals Level of performance: PL = e Safety category: 4 Safety Integrity Level: SIL 3 Cycle before dangerous failure: B10d=100,000 at 5A Risk duration: 20 ms max. Cable severing protection: yes (opening of safety lines) Safety contacts/diagnostics: 4x NO 8A/250V redundant / 1x NF redundant in series (test) and 8A/250V parallel (information) Indicators: 2 LEDs Reset: automatic Mounting: symmetrical DIN 35mm rail on DIN 50022 Mounting: IP 54 electrical box Electrical connection: Maximum 14 AWG (2.08 mm²) / 250V minimum Temperature: -20°C to +60°C