22.5mm DIN rail enclosure with removable terminals Economy of cabling (8 outputs for 255 functions) No programming Life cycle: 20 years Max activation distance: up to 45 mm Contact: 8 x 200 m APNP for 8-bit format Detection encoding: 16 million Indicator: 8 LEDs indicating the pathways activated Reset: no Mounting: symmetrical DIN 35mm rail after DIN 50022 Mounting: IP 54 electrical enclosure Material: PA6 Electrical connection: Maximum 14 AWG (2.08 mm²) Temperature: -15 °C to +60 °C Marking: label + serial number for traceability Option: badge nail, screw, plate screw, key chain, card ... etc.

Request for a quote

France

22.5mm DIN rail enclosure with removable terminals No software or PC configuration 8 combinable outputs Life cycle: 20 years Max activation distance: up to 45 mm Contact: 8 x 200 mA PNP for 8-bit format Detection encoding: 16 million Indicator: 8 LEDs indicating the pathways activated Action: Momentary (ref + M), bistable (ref + B), timed (ref + MKT) Mounting: symmetrical DIN 35mm rail after DIN 50022 Mounting: IP 54 electrical enclosure Material: PA6 Electrical connection: Maximum 14 AWG (2.08 mm²) Sealing: IP 67 Temperature: -15 °C to +60 °C Marking: label + serial number for traceability Option: badge nail, screw, plate screw, key chain, card ... etc.

Request for a quote

France

RFID sensor with 16 million codes Category 3 total security management without an external controller Programmable code through auto-learning (no software or PC) Level of performance with AWAX controller: up to PL = e Safety category without an external controller: 3 (EN 954-1) Cycle after dangerous failure: B10d = 2000000 at 2 Amps Max activation distance: up to 24 mm Security contact/diagnostics: 2 x redundant NO 2A/48V and 1 x 400mA PNP auxiliary Detection encoding: inviolable multicode Indicator: LED indicates code recognition Reset: automatic Attachment: 4 tamper-proof M4 screws (in base option: BH4) Mounting position: 2 (double wall brackets) Material: PA6 Electrical Connection: 3, 6, 12m cable (UL2464 PVC) or 50cm PUR cable with M12 connector (base + MKT) Sealing: IP 67 Temperature: -20 °C to +60 °C Marking: pad printing + serial number for traceability

Request for a quote

France

RFID sensor with 16 million codes Suitable for metallic environments Programmable code through auto-learning (no software or PC) Level of performance with AWAX controller: up to PL = e Safety category: up to 4 (EN 954-1) with AWAX controller Time to dangerous failure: MTTFd = 40 years Max activation distance: up to 24 mm Security contact/diagnostics: 2 x redundant NO 50mA/30V and 1 x 50mA auxiliary PNP Detection encoding: inviolable multicode Indicator: LED indicates code recognition Reset: automatic Attachment: 4 tamper-proof M4 screws (in base option: BH4) Mounting position: 2 (double wall brackets) Material: PA6 Electrical Connection: 50cm PUR cable with M12 connector Sealing: IP 67 Standing room temperature: -30 °C to +50 °C. Storage temperature: -40 °C to +85 °C Marking: pad printing + serial number for traceability Certificate: E2 10R-04 14053 (UTAC) ISO 7637-2 (Pulse 1, 2a, 2b, 3a, 3b, 4)

Request for a quote

France

RFID sensor with 16 million codes Lock control and two alarm levels Programmable code through auto-learning (no software or PC) Switching cycle: B10 = 1 million Max activation distance: up to 25 mm Contact/diagnostics: 1 x 1.8A PNP timed 5s/2 x 200m APNP Alarm 1 (120s failure to close) and 2 (30s breaking open) Duration of alarms editable upon request (XR530P, P1 ... P10) Detection encoding: 16 million Indicator: LED indicates code recognition Optional erasing card to reassign new codes Encoding of geographic location: (base + E1 to E10) Reset : automatic Attachment: 4 tamper-proof M4 screws (in base option: BH4) Mounting position: 2 (double wall brackets) Material: PA6 Electrical Connection: 3, 6, 12m (UL2464 PVC) Sealing: IP 67 Temperature: -25 °C to +70 °C. Marking: pad printing + serial number for traceability Option: badge nail, screw, plate screw, key chain, card ... etc. Application example: access to luxury showcases with lock control

Request for a quote

France

RFID sensor with 16 million codes Lock control and "burglar" alarm Supervision, traceability via PC, RS485 network and output contacts Life cycle: 20 years Max activation distance: up to 45 mm Contact/diagnostics: 1 x 1.8A PNP timed 5s/2 x 100mA PNP Alarm 1 (120s failure to close) and 2 (30s breaking open) Detection encoding: inviolable multicode Indicator: LED indicates code recognition Reset: automatic Attachment: 4 tamper-proof M4 screws (in base option: BH4) Mounting position: 1 Material: POLYCARBONATE Electrical Connection: 50cm PUR cable with M12 connector Sealing: IP 67 Temperature: -20 °C to +60 °C Marking: pad printing + serial number for traceability Options: - Software for real-time monitoring with openings traceability via PC (ref MDB13-SP.) - Software programming of badges and network configuration (ref MDB13-PR.) - Automatic network connection (LKS485): up to 8 cascading boxes and 4 readers per box or 32 readers. Individual contact outputs on each box - badge nail, screw, plate screw, key chain, card ... etc. Application example: access to luxury showcases with lock control and traceability

Request for a quote

France

Ultra-compact format Automatic RS485 networking with M12 connector output Deferral of all M12 connector outputs Indicator: LED indicates activation of the network Attachment: 4 M3 screws (with washers) Mounting position: 1 Material: POLYCARBONATE Electrical connection: 8 M12 connectors Sealing: IP 54 Temperature: -20 °C to +60 °C Marking: pad printing + serial number for traceability Options: - Software for real-time monitoring with openings traceability via PC (ref MDB13-SP.) - Software programming of badges and network configuration (ref MDB13-PR.) - Automatic network connection (LKS485): up to 8 cascading boxes and 4 readers per box or 32 readers. Individual contact outputs on each box - badge nail, screw, plate screw, key chain, card ... etc. Application example: access to luxury showcases with lock control and traceability

Request for a quote

France

Ultra-compact, very thin, plugs directly into the PLC Process management, sorting ... etc. MODBUS RS485 (RTU) or RS232 (ASCII) network Life cycle: 20 years Max activation distance: up to 45 mm Contact: 1 x strobe PNP /1 RS485 (base + 485) or RS232 (base + 232) Detection encoding: infinite Indicator: LED indicates code recognition Reset: automatic Mounting: M30 nut provided Mounting position: 1 Material: TR90UV Electrical connection: screwless terminal Sealing: IP 67 Temperature: -20 °C to +60 °C Marking: screen printing Options: - Stainless steel badge holder: AXKEF/CARD HOLDER - badge nail, screw, plate screw, key chain, card ... etc.

Request for a quote

France

Machine status signaling 4 types of selectable indications Low apparent thickness • Service life: 50,000 hours • Luminosity: 100 lm • Mode 1: flash • Mode 2: Flashing • Mode 3: Fixed • Mode 4: Revolving • Trim color: black, white, yellow, red • Attachment: 51mm bore and 2 to 6 D3 invisible screws (not included) • 8mm low visible thickness • Mounting position: 1 • Material TR90UV • Electrical connection: 1m 7 x 0.25mm² cable (other lengths on request) • Water resistance: IP 67 with peripheral silicone seal • Temperature: -5°C to +40°C. • Printing: screen printing for the reference on the back of the product

Request for a quote

France

Contactless coded electronic sensor Total safety management with an AWAX controller Cylindrical M18 for "invisible" assembly Level of performance with AWAX controller: up to PL = e Safety category: up to 4 with an AWAX controller Time before dangerous failure: MTTFd = 100 years Max. activation distance: 6 mm, 2 mm hysteresis Safety contacts/diagnostics: 2 x NO 0.8A max/24V redundant / 1xcontact PNP 250mA Detection encoding: mono-code inviolable Reset: automatic Attachment: 2 M30 nuts provided Mounting position: 1 Material: CuNi Electrical connection: M12 metal base Water resistance: IP 67 Temperature: -20°C to +60°C Marking: label + serial no. for traceability

Request for a quote

France

Dynamic detection of approaching hand even wearing gloves Fraud reduction system and MSD reduction Capacitive and optical technology touch button Performance level with COM3C controller: PL = e Safety category with COM3C: IIIC (EN 574), 4 (ISO 13849-1) 'Failsafe' level with COM3C: SIL 3 Time before dangerous failure: MTTFd = 100 years Activation distance: on touch (0 force = MSD reduction) Safety contacts: 1 x PNP NO/50mA OSSD and 1 x PNP NF/50mA OSSD Diagnostics: fraud, simultaneity, short-circuiting of contacts with multi-function illuminated ring Reset: automatic with two buttons correctly activated Attachment: Attachment: 51mm bore and 2 to 6 invisible D3 screws (not included) Mounting position: 1 Material: TR90UV yellow Electrical connection: 6-way screwless push terminal 1.5mm² Water resistance: IP 67 with silicone seal on the trim Temperature: -25°C to +60°C Marking: screen printed + serial no. for traceability Recommendations: use gloves in accordance with EN 388

Request for a quote

France

Contactless encoded electronic sensor with relay Category 3 total safety management without an external controller Suitable for groove profiles and single or double doors Level of performance without an external controller: PL = d Level of performance with AWAX controller: up to PL = e Safety category without an external controller: 3 Safety Integrity Level: SIL 2 Cycle before dangerous failure: B10d = 2,000,000 at 2A Max. activation distance: 8 mm, 3 mm hysteresis Safety contacts/diagnostics: 2 x NO 2A/48V redundant / 1 x PNP 250mA (X5) or 1xNF (X5.2) auxiliary Detection encoding: mono-code inviolable Indicator: LED indicates code recognition Reset: automatic (SR version) or Manual (AR version) Attachment: 4 tamper-proof M4 screws (optional ref: BH4). Suitable for grooved profiles. Screw caps provided. Mounting position: 1 Material: Polycarbonate Electrical connection: 1 M12 connector (X5 version) or 2 M12 connectors (X5.2 version for instant serial connection) Water resistance: IP 67/68 Temperature: -25°C to +60°C Marking: screen printed + serial no. for traceability Certification: TÜV Rheinland 01/205/5238/12 License Test Mark 968/EL 214.01/12

Request for a quote

France

Contactless encoded electronic sensor with relay Category 3 total safety management without an external controller 12V version for embedded applications Level of performance without an external controller: PL = c Level of performance with AWAX controller: up to PL = e Safety category without an external controller: 1 Cycle before dangerous failure: B10d = 2,000,000 at 50mA Max. activation distance: 10 mm, 2 mm hysteresis Safety contacts: 2 x NO 250 mA/48V redundant Detection encoding: mono-code inviolable Indicator: LED indicates code recognition Reset: automatic Attachment: 4 tamper-proof M3 screws (optional ref: BH3) Mounting position: 2 (double wall brackets) Material: PA6 Electrical Connection: 3, 6, 12m cable (UL2464 PVC) Water resistance: IP 67/68 Temperature: -20°C to +60°C Marking: pad printing + serial no. for traceability

Request for a quote

France

Contactless encoded electronic sensor with relay Category 3 total safety management without an external controller Level of performance without an external controller: PL = c Level of performance with AWAX controller: up to PL = e Safety category without an external controller: 1 Cycle before dangerous failure: B10d = 2,000,000 at 100mA Max. activation distance: 6 mm, 2 mm hysteresis Safety contacts/diagnostics: 2 x NO 1A/48V redundant / 1 x PNP 1A auxiliary Detection encoding: mono-code inviolable Indication: LED indicating code absence Reset: automatic Attachment: 2 M30 nuts provided Mounting position: 1 Material: CuNi Electrical connection: 3, 6, 12m cable Water resistance: IP 67 Temperature: -25°C to +60°C Marking: label + serial no. for traceability

Request for a quote

France

Redundant low and high pressure control with channel synchronization Pressure control from 0.1b to 300b (to be defined when ordering) Vacuum control from -0.2b to -0.9b (to be defined when ordering) • Level of performance with AWAX controller: up to PL = e • Level of performance only: PL = c • Safety category with an external controller: up to 4 • 'Integrated security' level with an external controller: up to SIL 3 • Cycle before dangerous failure: B10d = 100,000 • Safety contacts: 2 x NO 2A/50V • Auxiliary contact: 1 x PNP NF 2A/50V • Reset: automatic • Attachment: 4 x M4 flat head or domed screws • Mounting position: 1 • Material: Polycarbonate • Electrical connection: PUR UL20549 very durable 50 cm cord with M12 connector • Pneumatic connection: G1/4 and 8 mm quick connector • Water resistance: IP 65 • Ambient temperature: -25°C to +60°C • Fluid temperature: -40°C to 140°C (specify temperature and the nature of the fluid in the order) • Marking: label + serial no. for traceability

Request for a quote

France

RFID sensor with 16 million codes Suitable for metallic environments Programmable code through auto-learning (no software or PC) Max activation distance: up to 24 mm Security contact/diagnostics: 2 x 400mA and 1 x 200mA auxiliary PNP Detection encoding: inviolable multicode Indicator: LED indicates code recognition Reset: automatic Attachment: 4 tamper-proof M4 screws (in base option: BH4) Mounting position: 2 (double wall brackets) Material: PA6 Electrical Connection: 50cm PUR cable with M12 connector Sealing: IP 67 Standing room temperature: -25 °C to +70 °C. Storage temperature: -40 °C to +85 °C Marking: pad printing + serial number for traceability

Request for a quote

France

Manages person entry in hazard zones using an electrical locking key Contactless encoded electronic sensor with relay Category 3 total safety management without an external controller Electrical locking key with position contact Level of performance without an external controller: PL = d Level of performance with AWAX controller: up to PL = e Safety category without an external controller: 3 Safety Integrity Level: SIL 2 Cycle before dangerous failure: B10d = 2,000,000 at 2A Max. activation distance: 10 mm, 2 mm hysteresis Safety contacts/diagnostics: 2 x NO 2A/48V redundant / 2xPNP 250mA auxiliary (open/closed door and locking/unlocking of contacts) Detection encoding: mono-code inviolable Note: two-color LED indicates the key locking position; white LED indicates code recognition Reset: automatic Attachment: 4 tamper-proof M4 screws (optional ref: BH4) Mounting position: 2 (double wall brackets) Material: Polycarbonate Electrical connection: M12 metal base Water resistance: IP 65 Temperature: -15°C to +60°C Marking: screen printed + serial no. for traceability