Contactless coded electronic sensor Total safety management with an AWAX controller High temperature Level of performance with AWAX controller: up to PL = e Safety category: up to 4 with an AWAX controller Time before dangerous failure: MTTFd = 100 years Max. activation distance: 7 mm, 1 mm hysteresis, rotation ± 30° Safety contacts/diagnostics: 2 x NO 1A/24V redundant and 1 x PNP 1A auxiliary Detection encoding: mono-code inviolable Reset: automatic Attachment: 2 M4 screws not included; anti-rotation lugs provided Mounting position: 1 (4 x paste on screw-caps provided) Material: INOX 316L mirror polished Electrical connection: 50cm Ultra-soft silicone cord with M12 connector. Water resistance: IP 69K Temperature: -30°C to +110°C. Marking: laser engraving with mechanical punching of the serial number for permanent traceability