• europages
  • >
  • COMPANIES - SUPPLIERS - SERVICE PROVIDERS
  • >
  • safety sensors

Results for

Safety sensors - Import export

FranceBordeaux and AquitaineManufacturer/producer

France

Contactless coded electronic sensor Total safety management with an AWAX controller High temperature Level of performance with AWAX controller: up to PL = e Safety category: up to 4 with an AWAX controller Time before dangerous failure: MTTFd = 100 years Max. activation distance: 10 mm, 2 mm hysteresis Safety contacts/diagnostics: 2 x NO 1A/24V redundant and 1 x 250mA PNP contact Detection encoding: mono-code inviolable Reset: automatic Attachment: 4 tamper-proof M4 screws (optional ref: BH4) Mounting position: 2 (double wall brackets) Material: INOX 316L mirror polished Electrical connection: 50cm Ultra-soft silicone cord with M12 connector. Water resistance: IP 69K Extreme temperature: -40°C to +125°C Protective cover 316L stainless steel mirror polished "ref. + C" option Marking: laser engraving with mechanical punching of the serial number for permanent traceability

Request for a quote

France

High temperature, magnetic door holding, integrated 20N Contactless coded electronic sensor Total safety management with an AWAX controller Level of performance with AWAX controller: up to PL = e Safety category: up to 4 with an AWAX controller Time before dangerous failure: MTTFd = 100 years Max. activation distance: 3 mm, 1 mm hysteresis Holding Force: transmitter + receiver in contact = 20N Safety contacts/diagnostics: 2 x NO 0.8A/24V redundant and 1 x PNP 250mA Detection encoding: mono-code inviolable Reset: automatic Attachment: 4 tamper-proof M4 screws (optional ref: BH4) Mounting position: 2 (double wall brackets) Material: INOX 316L mirror polished Electrical connection: 50cm Ultra-soft silicone cord with M12 connector. Water resistance: IP 69K Extreme temperature: -40°C to +125°C Marking: laser engraving with mechanical punching of the serial number for permanent traceability

Request for a quote

France

40N integrated stainless steel magnetic door holding Contactless coded electronic sensor Total safety management with an AWAX controller Level of performance with AWAX controller: up to PL = e Safety category: up to 4 with an AWAX controller Time before dangerous failure: MTTFd = 360 years Max. activation distance: 3 mm, 2 mm hysteresis Holding Force: transmitter + receiver in contact = 40N Safety contacts/diagnostics: 2 x NO 0.8A max / 48V redundant and 1 x PNP 250mA Detection encoding: mono-code inviolable Reset: automatic Attachment: 4 tamper-proof M4 screws (optional ref: BH4) Mounting position: 1 Material: INOX 316L mirror polished Electrical Connection: 3, 6, 12m cable or 50cm cord PUR M12 (ref. + MKT) Water resistance: IP 67/68 (EPINUS-4K-MKT) and IP 69K (EPINUS-4K/SES) Temperature: -25°C to +70°C. Marking: laser engraving with mechanical punching of the serial number for permanent traceability

Request for a quote

France

Contactless coded electronic sensor Total safety management with an AWAX controller High temperature Level of performance with AWAX controller: up to PL = e Safety category: up to 4 with an AWAX controller Time before dangerous failure: MTTFd = 100 years Max. activation distance: 7 mm, 1 mm hysteresis, rotation ± 30° Safety contacts/diagnostics: 2 x NO 1A max/24V redundant and 1 x PNP 1A auxiliary Detection encoding: mono-code inviolable Reset: automatic Attachment: 2 central M4 screws not included; anti-rotation lugs provided Mounting position: 1 Material: INOX 316L mirror polished Electrical connection: 50cm Ultra-soft silicone cord with M12 connector. Water resistance: IP 69K Operating temperature: -30°C to +110°C. Peak temperature: -40°C to +130°C Marking: laser engraving with mechanical punching of the serial number for permanent traceability

Request for a quote

France

Contactless coded electronic sensor Total safety management with an AWAX controller High temperature Level of performance with AWAX controller: up to PL = e Safety category: up to 4 with an AWAX controller Time before dangerous failure: MTTFd = 100 years Max. activation distance: 7 mm, 1 mm hysteresis, rotation ± 30° Safety contacts/diagnostics: 2 x NO 1A/24V redundant and 1 x PNP 1A auxiliary Detection encoding: mono-code inviolable Reset: automatic Attachment: 2 M4 screws not included; anti-rotation lugs provided Mounting position: 1 (4 x paste on screw-caps provided) Material: INOX 316L mirror polished Electrical connection: 50cm Ultra-soft silicone cord with M12 connector. Water resistance: IP 69K Temperature: -30°C to +110°C. Marking: laser engraving with mechanical punching of the serial number for permanent traceability

Request for a quote

Do you sell or make similar products?

Sign up to europages and have your products listed

Add my business

France

Atex and machine safety management in a compact 45 mm format Atex dual-channel insulation barrier and controller for built-in machinery safety Atex safety ATEX standards EN 60079-0 EN 60079-11 EN 60079-25 EN 60079-26 ATEX marking [Ex ia] IIC Ga [Ex ia] IIIC Da II(1)GD Product used in combination with the "ANATOM78S- (PL or OX)-EEX" sensor Machine Safety Performance level with AWAX controller: PL = e in accordance with ISO 13849-1 Safety category: 4 in accordance with ISO 13849-1 Time before dangerous failure: MTTFd = 120 years Cycle before dangerous failure: B10d=100,000 at 5A Risk duration: 20 ms max. Cable severing protection: yes (opening of safety lines) Short-circuit protection and overload protection: yes (system shutdown). Requires return to a service workshop for a total control and troubleshooting. Safety contacts/diagnostics: 3x NO 8A/250V redundant / 1x NF 8A/250V redundant parallel Indicators: 3 LEDs Reset: configurable by dip-switch (SR=Automatic, N=manual) Mounting: symmetrical DIN 35mm rail on DIN 50022 Mounting: IP 54 electrical box Electrical connection: Maximum 14 AWG (2.08 mm²) / 250V minimum Temperature: -20°C to +40°C. Certification: INERIS 06ATEX0007X

Request for a quote

France

Contactless coded electronic sensor Total safety management with an AWAX controller Cylindrical M18 for "invisible" assembly Level of performance with AWAX controller: up to PL = e Safety category: up to 4 with an AWAX controller Time before dangerous failure: MTTFd = 100 years Max. activation distance: 6 mm, 2 mm hysteresis Safety contacts/diagnostics: 2 x NO 0.8A max/24V redundant / 1xcontact PNP 250mA Detection encoding: mono-code inviolable Reset: automatic Attachment: 2 M30 nuts provided Mounting position: 1 Material: CuNi Electrical connection: M12 metal base Water resistance: IP 67 Temperature: -20°C to +60°C Marking: label + serial no. for traceability

Request for a quote

France

Contactless coded electronic sensor Total safety management with an AWAX controller Low cost solution for multi-access applications Level of performance with AWAX controller: up to PL = e Safety category: up to 4 with an AWAX controller Time before dangerous failure: MTTFd = 420 years Max. activation distance: 9 mm, 1 mm hysteresis Safety contacts/diagnostics: 2 x NO 0.4A max / 24V redundant and 1 x 250mA PNP contact Detection encoding: mono-code inviolable Indicator: LED indicates code recognition Reset: automatic Attachment: 4 tamper-proof M3 screws (optional ref: BH3) Mounting position: 2 (double wall brackets) Material: PA6 or INOX 316L mirror polished (ref. + OX) Electrical Connection: 3, 6, 12m cable (UL2464 PVC) or 50cm cord with M12 connector (UL20549 PUR) (ref. + MKT) Water resistance: IP 67/68 or IP 69K stainless steel version (requires cable input protection) Temperature: -20°C to +60°C Marking: pad printing + serial no. for traceability

Request for a quote

France

Contactless coded electronic sensor Total safety management with an AWAX controller Low cost solution for multi-access applications • Level of performance with AWAX controller: up to PL = e • Safety category: up to 4 with an AWAX controller • Time before dangerous failure: MTTFd = 334 years • Max. activation distance: 10 mm, 2 mm hysteresis • Safety contacts/diagnostics: 2 x NO 0.8A max / redundant 24V / 1xcontact PNP 250mA • Detection encoding: mono-code inviolable • Indicator: LED indicates code recognition • Reset: automatic • Attachment: 4 tamper-proof M4 screws (optional ref: BH4) • Mounting position: 78S-98S, 78SMKT, 78SMKT130 versions: 2 (double wall brackets) • Mounting position: 78SM12 and 98SM12 versions: 1 • Material: 78S-98S, 78SMKT, 78SMKT130: PA6 or INOX316L (ANATOM78S-OX or ANATOM78S-OX-MKT) • Matierial for 78SM12, 78SESM12 and 98SM12 : polycarbonate (PC) • Electrical Connection: 3, 6, 12m cable (78S/98S) or 50cm cord with M12 connector (ref. + MKT) or 130cm cord with M12 connector (ref. + MKT130) or M12 metal (ref. + M12) • Water resistance: IP 67/68 (PA6, PC) or IP 69K with stainless steel - new generation • Temperature: -25°C to +60°C • Marking: PA6 pad printing + serial no., PC pad printing + serial no., INOX316L laser engraving with mechanically punched serial no. for permanent traceability • Certification: UL 508 / C22.2 no.14 C-UL-US listed 34CB (file E214209) (Not applicable for versions MKT and M12)

Request for a quote
Filters

Results for

Safety sensors - Import export

Number of results

10 Products

Category