• europages
  • >
  • COMPANIES - SUPPLIERS - SERVICE PROVIDERS
  • >
  • automatic switches

Results for

Automatic switches - Import export

France

France

Verified by Europages

If you want to carry out redundancy tests to check your installations, we advise you to rent this ATS (Automatic Transfer Switch) box in addition to your load bank. This will allow you to switch the electrical load between channel A and channel B without having to disconnect and reconnect the cables.

Request for a quote

France

Verified by Europages

CDA’s E-Fill SW Monoblock is designed to deliver exceptional performance and adaptability to the fully automatic packaging line from which it originates. This SW version excels in the filling, screwing, and labelling of bottles (e-liquid, essential oils, flavours, dyes, reagents…) ranging from 5 to 250ml in various formats. It operates in two modes: Fully automatic mode for large product series, utilizing the Pick & Place system for automatic cap positioning and screw capping. "Switch" mode caters to small and medium product series, incorporating manual cap dispensing on the bottle and automatic screw capping. The switch mode facilitates the bottling of different product formats without complex handling or adjustments. Doors can be opened to allow an operator to manually dispense caps, which are then automatically capped on filled bottles by a specific automatic capper. With a speed of up to 3000 bottles/hour, the E-Fill SW can be equipped with up to 2 labelling stations.

Request for a quote

France

Atex and machine safety management in a compact 45 mm format Atex dual-channel insulation barrier and controller for built-in machinery safety Atex safety ATEX standards EN 60079-0 EN 60079-11 EN 60079-25 EN 60079-26 ATEX marking [Ex ia] IIC Ga [Ex ia] IIIC Da II(1)GD Product used in combination with the "ANATOM78S- (PL or OX)-EEX" sensor Machine Safety Performance level with AWAX controller: PL = e in accordance with ISO 13849-1 Safety category: 4 in accordance with ISO 13849-1 Time before dangerous failure: MTTFd = 120 years Cycle before dangerous failure: B10d=100,000 at 5A Risk duration: 20 ms max. Cable severing protection: yes (opening of safety lines) Short-circuit protection and overload protection: yes (system shutdown). Requires return to a service workshop for a total control and troubleshooting. Safety contacts/diagnostics: 3x NO 8A/250V redundant / 1x NF 8A/250V redundant parallel Indicators: 3 LEDs Reset: configurable by dip-switch (SR=Automatic, N=manual) Mounting: symmetrical DIN 35mm rail on DIN 50022 Mounting: IP 54 electrical box Electrical connection: Maximum 14 AWG (2.08 mm²) / 250V minimum Temperature: -20°C to +40°C. Certification: INERIS 06ATEX0007X

Request for a quote

France

Safety management in 2 zones in a compact 45 mm format Short-circuit detection in 2 µs, self-resetting Removable terminals Performance level with AWAX controller: PL = e Safety category: 4 Safety Integrity Level: SIL 3 Time before dangerous failure: MTTFd = 415 years Cycle before dangerous failure: B10d=100,000 at 5A Risk duration: 20 ms max. Cable severing protection: yes (opening of safety lines) Short-circuit and overload protection: yes, using DLC (opening of safety lines and current limiting in contacts) Reaction 2 µs ultrafast Safety contacts/diagnostics zone 1: 3x NO 8A/250V redundant / 1x NF 8A/250V redundant series Safety contacts/diagnostics zone 2: 3x NO 8A/250V redundant / 1x NF 8A/250V redundant series Indicators: 2 display LEDs per zone for diagnostics and 1 LED for power Reset: configurable by dip-switch (SR=Automatic, N=manual) Mounting: symmetrical DIN 35mm rail on DIN 50022 Mounting: IP 54 electrical box Electrical connection: Maximum 14 AWG (2.08 mm²) / 250V minimum Temperature: -20°C to +60°C Certification: TÜV Rheinland 01/205/5168/11

Request for a quote

France

Safety management on 9 outputs in a compact 45mm housing Short-circuit detection in 2 µs, self-resetting Removable terminals Performance level with AWAX controller: PL = e Safety category: 4 Safety Integrity Level: SIL 3 Time before dangerous failure: MTTFd = 75 years Cycle before dangerous failure: B10d=100,000 at 5A Risk duration: 20 ms max. Cable severing protection: yes (opening of safety lines) Short-circuit and overload protection: yes, using DLC (opening of safety lines and current limiting in contacts) Reaction 2 µs ultrafast Safety contacts/diagnostics: 3x NO 8A/250V redundant / 1x NF 8A/250V redundant in serial (XXL version) or parallel (XXLP version) Indicators: 3 LEDs for diagnostics Reset: configurable by dip-switch (SR=Automatic, N=manual) Mounting: symmetrical DIN 35mm rail on DIN 50022 Mounting: IP 54 electrical box Electrical connection: Maximum 14 AWG (2.08 mm²) / 250V minimum Temperature: -20°C to +60°C Certification: TÜV Rheinland 01/205/5168/11

Request for a quote

Do you sell or make similar products?

Sign up to europages and have your products listed

Add my business

France

Safety management with 85~265 VAC power Short-circuit detection in 2 µs, self-resetting Removable terminals Performance level with AWAX controller: PL = e Safety category: 4 Safety Integrity Level: SIL 3 Time before dangerous failure: MTTFd = 415 years Cycle before dangerous failure: B10d=100,000 at 5A Risk duration: 20 ms max. Cable severing protection: yes (opening of safety lines) Short-circuit and overload protection: yes, using DLC (opening of safety lines and current limiting in contacts) Reaction 2 µs ultrafast Safety contacts/diagnostics: 3x NO 8A/250V redundant / 1x NF 8A/250V parallel redundant Indicators: 3 LEDs for diagnostics Reset: configurable by dip-switch (SR=Automatic, N=manual) Mounting: symmetrical DIN 35mm rail on DIN 50022 Mounting: IP 54 electrical box Electrical connection: Maximum 14 AWG (2.08 mm²) / 250V minimum Temperature: -20°C to +60°C

Request for a quote

France

USE : For night Works or in tunnel. ADVANTAGES : All safety Equipment, no dazzling, very easy to use, ( self-inflating) in accordance with European Regulations. LIGHTING BALLOON fixed Leg Tripod - BEC This Balloon has been specially studied for track works and the swift rescue actions. It comprises a Blowing-up Device by over-pressure inside of an elliptical Balloon, and a powerful Halogen Lighting protected by a grate. The Blowing-up and switching on are automatic in 45 sec. POWER 2000 W - 230 V BALLOON Diameter 1.10 m Other Characteristics Intensity: 10 A (Safety by fuse-block) Protection Index : IP. 43 1 Halogen Lamp Bulb : 2000 W Useful Life : 1000 h Resistance to Wind : 100 Km/h Lighted Area : 1400 m² Adjusting of Height : 2.5 m to 5 m Blowing-up time : 45 secondes Net Weights : 16 Kg (with Tripod) / 20 Kg (with Heavy Foot) Packing : Plastic tube Ø 30 cm - Length 115 cm - Weight = 8 Kg MOVABLE LIGHTING SET - GEC 1 BEC Lighting Balloon - (See the Characteristics above) 1 P

Request for a quote

France

The POUGET VT.3 Vibrating Tamping Set is supplied with : 1 Generating Set (petrol or diesel) three phase 220/380 V-50 Hz with an automatic safety brake, mounted on 2 rubber wheels. Fuel Motor Power (KVA) Weight (Kg) Essence HONDA LOMBARDINI 6 7 100 106 Diesel HATZ LOMBARDINI 6 112 4 Portable Vibrating Tampers at individual drive with automatic safety brake switch, and 10 meters insulated protective cable. . - Multiple vibrating directions - Unit power = 0,77 KW - Vibrations/min. : 50 Hz - Vibrating strength of tamping-blade : 660 Kg - Hardeness of tips = 63/68 Rockwell C - Unit weight of each tamper : 32 Kg The Portable Vibrating Tamping Machine is equipped with an operating adjustable handle in height and one safety brake switch. 1 Distributor Panel with : - 1 cable reel comprising 50 m. - 1 emergency stop button - 4 security connection - 1 general brake - weight = 32 Kg Noise level for the Workmen in operation : 90 dB (A) Vibrating level on Workmen handles : 5 m/s² IMPORTANT :

Request for a quote