HAGO BAUTECHNIK GMBH
Austria
Load capacity: 125 kN test load EN 124. Material: Frame and cover in 2 mm cold-formed precision steel profiles. Hot-dip galvanised. Fire protection panel on stainless steel Z-brackets, fire-resistant seal. Features: Accurately-manufactured smell proof access cover. Tapered design allows easy opening. Virtually invisible when installed. Robust steel mesh reinforcement. Fire test certificate: The Austrian test certificate issued by the Institute for Fire Protection Technology and Safety Research (IBS) confirms that HAGODECK Type BV-F90 steel resists a fire for 90 minutes and thus significantly contributes to safety in the event of a fire. In accordance with EN 13501-2, Type BV-F90 is classified in fire resistance class REI 90 (a ↔ b). The Lift-Off opening system: Every HAGODECK Type BV-F90 steel cover comes with a set of lifting keys and precise installation instructions. After lifting out the cover, the fire protection panel can be removed using its grab handle. The shaft is...
Request for a quoteARMACELL GMBH
Germany
THE FIRE SLEEVE TO STOP FIRE SPREADING THROUGH PLASTIC PIPES INSULATED WITH ARMAFLEX Armaprotect PP is a Pipe collar for creating pipe penetration seals of fire resistance class R90. It is a solid metal sleeve which is equipped with several layers of the high performance intumescent material. In the event of a fire, the intumescent material expands with high pressure and thus seals the opening hermetically against flames and smoke.
PERGEL METAL
Turkey
Fire cabinets are not automatic and are used as fire installations. It is an important material. It is especially very important for building design. It is usually mounted on the wall and used. Inside there is a hose that is resistant to fire. This hose is a non-folding hose that is coated on the outside. It is used to extinguish fires. The design of fire cabinets is very important. It must be present on every floor. The distance between the two sections should be set very decently. It is very important that there are no more than two deckers on one floor, and there are no more than 30 meters between them. Nowadays, it is a material needed in most fields.
Request for a quotePFP
Luxembourg
The purpose of fire compartmentation is to to prevent the spread of fire to or from another part of the same building or an adjoining building. The compartment wall seperate the fire risk areas in a building (low, medium and high risk). The higher the fire risk in the area, the more fire resistant the compartment (30 minutes, 60 minutes, 90 minutes or 120 minutes). It also depends on the type of building and its height. Fire compartments are achieved by means of: Fire doors, curtains, shutters Fireproof partitions Fireproof ceilings Fire-stop closures Consult our professionals Do not hesitate to contact us, we can draw up an estimate together to find the best solution for your security.
Request for a quotePFP
Luxembourg
The Fibreflam ISO6 curtain is a flexible partitioning curtain without irrigation. With a fire resistance degree of EI60, it also conforms to the DAS NF S61-937-1 and -4 standard. Thanks to its control panel and its motor operating in 400V, the closure of the curtain is obtained by gravity in case of fire alarm. Only its reopening is motorised. The standard dimensions of this fire curtain are up to 4.36 m wide and 4.21 m high. In spaces with strong architectural constraints, this curtain can easily be hidden behind cladding. We can help you with this project, so don't hesitate to submit your requirements via this contact form or by clicking on our website
Request for a quoteDo you sell or make similar products?
Sign up to europages and have your products listed
GB GROUP 3D DECOR LTD
United Kingdom
Fire Resistant Plasterboard Type DF consists of gypsum core reinforced with special additives and clay, enclosed between special paper for enhanced fire resistance. Application: • Ceiling • Wall • Areas with higher requirements for fire protection such as evacuation corridors, stairways, industrial premises, etc. Ideal for indoor use in areas with normal humidity up to 60% Advantages: • High density of gypsum core for better sound insulation and stability Type D • Increased resistance to high temperatures Type F • Easy to cut and mount TECHNICAL INFORMATION: Thickness (mm) Width (mm) Length (mm) Weight (kg/m2) Sheets per pallet 12.5 1200 2000-3000 10.00 60 pcs 15 1200 2000 12.50 50 pcs
Request for a quoteAPERTE, UAB
Lithuania
Glass type - EI30, EI60, EI90, EI120. Max. tested dimensions range - 4200 – 2200 mm. Notes - *Fire-resistant Glass may be bended.
Request for a quoteAPERTE, UAB
Lithuania
Glass type - EW30, EI30, EI60, EI90, EI120. Max. tested dimensions range - 4200 – 2200 mm, Notes - IGUs may incorporated various types of coating e.g. LowE . They give additional functions in the form of thermal Insulation (factor U), solar protection (factor g), give a specific color of glass and reflective. Fire-resistant Glass Units may be bended.
Request for a quoteBIENTECH TECHNIC TEXTILE LIMITED STI
Turkey
Fire Resistant Softshell 2-3 layer 320-380 grm2 Term: 5-8 weeks Minimum: Per color 1000 mts Payment : 50/50
Request for a quoteResults for