Types of Industrial Fans Maintenance Partners provides services on various types of fans, for example: Centrifugal Axial Fan units (fan + motor) Directly driven Indirectly driven (chain or belt) Fan Services Our services range from standard inspections and repairs to complete overhauls. A repair or overhaul of a fan generally consists of an Inspection, Repair/Modification and a final Report. Inspection The first step when repairing a fan is the inspection. Fan inspections include: Visual inspection Alignment check Checks of belts and couplings Measurement of axial clearances Disassembly + visual inspection of parts Dimensional measurements When the inspection is finished, an inspection report is drawn up with recommendations for repair. Execution of works After approval of the recommendations for repair, the execution of the repair / overhaul works begins. The scope of work may vary, but can include: Cleaning & steaming Sandblasting Preparation of technical drawings for...

Request for a quote

Belgium

Verified by Europages

Fan Services Our services range from standard inspections and repairs to complete overhauls. A repair or overhaul of a fan generally consists of an Inspection, Repair/Modification and a final Report. Inspection The first step when repairing a fan is the inspection. Fan inspections include: Visual inspection Alignment check Checks of belts and couplings Measurement of axial clearances Disassembly + visual inspection of parts Dimensional measurements When the inspection is finished, an inspection report is drawn up with recommendations for repair. Execution of works After approval of the recommendations for repair, the execution of the repair / overhaul works begins. The scope of work may vary, but can include: Cleaning & steaming Sandblasting Preparation of technical drawings for machining by in-house engineering team Machining of parts (bearing housings, rotors, …) Balancing of rotating parts Coating of rotating parts Assembly Coating of exterior

Request for a quote

Belgium

Complete fan unit for tool-free mounting on surfaces. Air throughput from 20 - 900 m³/h, standard protection category IP 54. SK fan and filter units TopTherm, 20/25 m³/h, 230 V, 1~, 50/60 Hz, WHD: 116.5 x 116.5 x 16 mm

Request for a quote

Belgium

Enclosure heaters to regulate relative humidity, prevent temperatures from dropping below the dew point and stop condensation forming inside the enclosure. This prevents consequential damage associated with corrosion or electrical short circuits. SK enclosure heater, without fan, 8-10 W, 110-240 V, 1~, 50/60 Hz, WHD: 45 x 120 x 46 mm

Request for a quote

Belgium

Plume-abated fan assisted natural draft or circular hybrid cooling tower is the best technical solution for large heat loads and stringent plume abatement requirements.Seawater application. If overall height is limited. To keep countryside free from visible plume formations and shadow .For locations close to residential areas .To facilitate permission processes. ADVANTAGES VS CELL TYPE HYBRID COOLING TOWER: Compact arrangement/space saving. No recirculation and interference effects. No wash down (grounding) effects of plume. Use of natural draft. No corrosion due to humidity and salinity in the neighborhood. Visually an interesting architectural structure.

Request for a quote

Do you sell or make similar products?

Sign up to europages and have your products listed

Add my business

Belgium

This 3-step control switch regulates EC fans, damper actuators, AC fan speed controllers or frequency inverters. It needs 10 VDC supply voltage. The device has an OFF position to stop the motor completely. Thus, the output signal is divided into 4 steps: 0 VDC and 3 other output voltages. The output for position 3 always equals the supplied voltage i.e. 10 VDC. The output ranges for positions 1 and 2 can be adjusted via internal trimmers. There is also a version with 2 predetermined voltage steps: SMT-D-4P-EM

Request for a quote

Belgium

This fan speed controller is used to control EC fan speed. The unregulated output can control a water valve or an electric heating element. Via the rotary knob the temperature can be set between 5 - 35°C. Fan speed is regulated manually in 5 steps, there's an Off-position and automatic mode. In automatic mode a temperature sensor PT500 is required. Choice between cooling/heating mode can be done via Modbus communication or a jumper. This controller can be connected to our SenteraWeb or a BMS-system. .

Request for a quote

Belgium

This controller regulates the fan speed of single-phase motors from 1,5 to 10 A via phase angle control a.k.a. Triac technology. The supply voltage of 230 VAC can be turned off via the illuminated ON/OFF switch on the side of the unit. Via de potentiometer located on the front of the controller you can set the desired fan speed. Minimum speed can be adjusted via an internal trimmer and kickstart/softstart by adding/removing a jumper on the PCB of the controller. This controller is typically used to regulate the speed of AC fans or centrifugal pumps in HVAC systems. The regulator is also available with TK monitoring. This function will deactivate the motor in case of overheating. The code for this type of regulator suitable for 1,5 A is ITRS-15-DT.

Request for a quote