• europages
  • >
  • COMPANIES - SUPPLIERS - SERVICE PROVIDERS
  • >
  • bare wire

Results for

Bare wire - Import export

Turkey

TELMAKSAN specialized in manufacturing aluminum and aluminum alloy wires in both medium and fine diameters. Telmaksan aluminum wire facility is recognized as the Europe's fastest, as well as leading manufacturer of bare aluminum wire and aluminum alloy wire products. Due to our flexible production system even requirements for smaller quantities can be accommodated with a short production lead time. The lightness, flexibility, excellent conductivity and resistance to corrosion make aluminum wire the ideal material for many different uses. Its production is aimed at technological improvement and quality control to achieve best results for its customers’ requirements.

Request for a quote

Germany

Verified by Europages

This inline thermocouple can be individually installed. For measurements in the wiring harness, on difficult to access points or on the smallest components. The thin wire, barely 0.7 mm in diameter, facilitates highly flexible installation. The thin probe tip guarantees very rapid response. Temperature range: :-190 °C to +260 °C, short-duration to +300 °C Wire type: Teflon,0.08 mm, wire, Tmax: +300 °C

Request for a quote

Germany

Verified by Europages

This inline thermocouple can be individually installed. For measurements in the wiring harness, on difficult to access points or on the smallest components. The thin wire, barely 2 mm in diameter, facilitates highly flexible installation. The thin probe tip guarantees very rapid response. Temperature range: -100 °C to + +200 °C, short-duration to + 230 °C Wire type: Teflon, 0.2 mm, wire, Tmax: +200 °C

Request for a quote

Germany

Verified by Europages

Sheathing thermocouples can be used anywhere due to their ruggedness and small design. Whether in industry, development or in the lab. The measurement point comes insulated as standard to exclude any falsification of the measurement evaluation through superposition of the offsets. The connection lead permits simple routing up to the measured-data acquisition. Options are available for the probe diameter and wire length as well as the type of connection configuration (plug, socket, bare wire ends, etc.). Temperature range: -100 °C to +800 °C, continuous, depending on selected sheathing diameter and measuring medium or atmosphere Wire type: Teflon with CU shielding, Tmax: +200 °C, continuous

Request for a quote

Germany

Verified by Europages

Sheathing thermocouples can be used anywhere due to their ruggedness and small design. Whether in industry, development or in the lab. The measurement point comes insulated as standard to exclude any falsification of the measurement evaluation through superposition of the offsets. The connection lead permits simple routing up to the measured-data acquisition. Options are available for the probe diameter and wire length as well as the type of connection configuration (plug, socket, bare wire ends, etc.). Temperature range: -100 °C to +1.100 °C, continuous, depending on selected sheathing diameter and measuring medium or atmosphere Wire type: Silicone, Tmax: +180 °C, continuous

Request for a quote

Germany

Verified by Europages

Sheathing thermocouples can be used anywhere due to their ruggedness and small design. Whether in industry, development or in the lab. The measurement point comes insulated as standard to exclude any falsification of the measurement evaluation through superposition of the offsets. The connection lead permits simple routing up to the measured-data acquisition. Options are available for the probe diameter and wire length as well as the type of connection configuration (plug, socket, bare wire ends, etc.). Temperature range: -100 °C to +1.100 °C, continuous, depending on selected sheathing diameter and measuring medium or atmosphere Wire type: Fibreglass with VA braid, Tmax: +450 °C, continuous

Request for a quote

Germany

Verified by Europages

Sheathing thermocouples can be used anywhere due to their ruggedness and small design. Whether in industry, development or in the lab. The measurement point comes insulated as standard to exclude any falsification of the measurement evaluation through superposition of the offsets. The connection lead permits simple routing up to the measured-data acquisition. Options are available for the probe diameter and wire length as well as the type of connection configuration (plug, socket, bare wire ends, etc.). Temperature range: -100 °C to +1.100 °C, continuous, depending on selected sheathing diameter and measuring medium or atmosphere Wire type: Teflon with CU shielding, Tmax: +200 °C, continuous

Request for a quote

Germany

Verified by Europages

Sheathing thermocouples can be used anywhere due to their ruggedness and small design. Whether in industry, development or in the lab. The measurement point comes insulated as standard to exclude any falsification of the measurement evaluation through superposition of the offsets. The connection lead permits simple routing up to the measured-data acquisition. Options are available for the probe diameter and wire length as well as the type of connection configuration (plug, socket, bare wire ends, etc.). Temperature range: -100 °C to +260 °C, continuous Wire type: Teflon with CU shielding, Tmax: +200 °C, continuous

Request for a quote

Germany

Verified by Europages

Sheathing thermocouples can be used anywhere due to their ruggedness and small design. Whether in industry, development or in the lab. The measurement point comes insulated as standard to exclude any falsification of the measurement evaluation through superposition of the offsets. The connection lead permits simple routing up to the measured-data acquisition. Options are available for the probe diameter and wire length as well as the type of connection configuration (plug, socket, bare wire ends, etc.). Temperature range: -100 °C to +180 °C, continuous Wire type: Silicone, Tmax: +180 °C, continuous

Request for a quote

Germany

Verified by Europages

Sheathing thermocouples can be used anywhere due to their ruggedness and small design. Whether in industry, development or in the lab. The measurement point comes insulated as standard to exclude any falsification of the measurement evaluation through superposition of the offsets. The connection lead permits simple routing up to the measured-data acquisition. Options are available for the probe diameter and wire length as well as the type of connection configuration (plug, socket, bare wire ends, etc.). Temperature range: -100 °C to +550 °C, continuous Wire type: Fibreglass with VA braid, Tmax: +450 °C, continuous

Request for a quote

Germany

Verified by Europages

Sheathing thermocouples can be used anywhere due to their ruggedness and small design. Whether in industry, development or in the lab. The measurement point comes insulated as standard to exclude any falsification of the measurement evaluation through superposition of the offsets. The connection lead permits simple routing up to the measured-data acquisition. Options are available for the probe diameter and wire length as well as the type of connection configuration (plug, socket, bare wire ends, etc.). Temperature range: -100 °C to +260 °C, continuous Wire type: Teflon with CU shielding, Tmax: +200 °C, continuous

Request for a quote

Germany

Verified by Europages

Sheathing thermocouples can be used anywhere due to their ruggedness and small design. Whether in industry, development or in the lab. The measurement point is hot junction insulated as standard to exclude any falsification of the measurement evaluation through superposition of the offsets. Sheathing thermocouples are freely flexible across their entire length. That means the thermocouple can be integrated in the installation point. The temperature to be measured can therefore be registered near the desired measuring point. A possible connection lead permits simple routing up to the measured-data acquisition. Options are available for the element diameter, element and wire length as well as the type of connection configuration (plug, socket, bare wire ends, etc.). Temperature range: -100 °C to +1.100 °C, continuous, depending on selected sheathing diameter and measuring medium or atmosphere

Request for a quote

Germany

Verified by Europages

Sheathing thermocouples can be used anywhere due to their ruggedness and small design. Whether in industry, development or in the lab. The measurement point is hot junction insulated as standard to exclude any falsification of the measurement evaluation through superposition of the offsets. Sheathing thermocouples are freely flexible across their entire length. That means the thermocouple can be integrated in the installation point. The temperature to be measured can therefore be registered near the desired measuring point. A possible connection lead permits simple routing up to the measured-data acquisition. Options are available for the element diameter, element and wire length as well as the type of connection configuration (plug, socket, bare wire ends, etc.). Temperature range: -100 °C to +1.100 °C, continuous, depending on selected sheathing diameter and measuring medium or atmosphere Wire type: Silicone, Tmax: +180 °C continuous

Request for a quote

Germany

Verified by Europages

Sheathing thermocouples can be used anywhere due to their ruggedness and small design. Whether in industry, development or in the lab. The measurement point is hot junction insulated as standard to exclude any falsification of the measurement evaluation through superposition of the offsets. Sheathing thermocouples are freely flexible across their entire length. That means the thermocouple can be integrated in the installation point. The temperature to be measured can therefore be registered near the desired measuring point. A possible connection lead permits simple routing up to the measured-data acquisition. Options are available for the element diameter, element and wire length as well as the type of connection configuration (plug, socket, bare wire ends, etc.). Temperature range: -100 °C to +750 °C, continuous, depending on selected sheathing diameter and measuring medium or atmosphere

Request for a quote

Germany

Verified by Europages

Sheathing thermocouples can be used anywhere due to their ruggedness and small design. Whether in industry, development or in the lab. The measurement point is hot junction insulated as standard to exclude any falsification of the measurement evaluation through superposition of the offsets. Sheathing thermocouples are freely flexible across their entire length. That means the thermocouple can be integrated in the installation point. The temperature to be measured can therefore be registered near the desired measuring point. A possible connection lead permits simple routing up to the measured-data acquisition. Options are available for the element diameter, element and wire length as well as the type of connection configuration (plug, socket, bare wire ends, etc.). Temperature range: -100 °C to +750 °C, continuous, depending on selected sheathing diameter and measuring medium or atmosphere Wire type: Silicone, Tmax: +180 °C

Request for a quote

Germany

Verified by Europages

Sheathing thermocouples can be used anywhere due to their ruggedness and small design. Whether in industry, development or in the lab. The measurement point is hot junction insulated as standard to exclude any falsification of the measurement evaluation through superposition of the offsets. Sheathing thermocouples are freely flexible across their entire length. That means the thermocouple can be integrated in the installation point. The temperature to be measured can therefore be registered near the desired measuring point. A possible connection lead permits simple routing up to the measured-data acquisition. Options are available for the element diameter, element and wire length as well as the type of connection configuration (plug, socket, bare wire ends, etc.).

Request for a quote

Germany

Verified by Europages

Sheathing thermocouples can be used anywhere due to their ruggedness and small design. Whether in industry, development or in the lab. The measurement point is hot junction insulated as standard to exclude any falsification of the measurement evaluation through superposition of the offsets. Sheathing thermocouples are freely flexible across their entire length. That means the thermocouple can be integrated in the installation point. The temperature to be measured can therefore be registered near the desired measuring point. A possible connection lead permits simple routing up to the measured-data acquisition. Options are available for the element diameter, element and wire length as well as the type of connection configuration (plug, socket, bare wire ends, etc.).

Request for a quote

Do you sell or make similar products?

Sign up to europages and have your products listed

Add my business

Germany

Verified by Europages

Sheathing thermocouples can be used anywhere due to their ruggedness and small design. Whether in industry, development or in the lab. The measurement point is hot junction insulated as standard to exclude any falsification of the measurement evaluation through superposition of the offsets. Sheathing thermocouples are freely flexible across their entire length. That means the thermocouple can be integrated in the installation point. The temperature to be measured can therefore be registered near the desired measuring point. A possible connection lead permits simple routing up to the measured-data acquisition. Options are available for the element diameter, element and wire length as well as the type of connection configuration (plug, socket, bare wire ends, etc.).

Request for a quote

Germany

Verified by Europages

Sheathing thermocouples can be used anywhere due to their ruggedness and small design. Whether in industry, development or in the lab. The measurement point is hot junction insulated as standard to exclude any falsification of the measurement evaluation through superposition of the offsets. Sheathing thermocouples are freely flexible across their entire length. That means the thermocouple can be integrated in the installation point. The temperature to be measured can therefore be registered near the desired measuring point. A possible connection lead permits simple routing up to the measured-data acquisition. Options are available for the element diameter, element and wire length as well as the type of connection configuration (plug, socket, bare wire ends, etc.).

Request for a quote

Germany

Verified by Europages

Sheathing thermocouples can be used anywhere due to their ruggedness and small design. Whether in industry, development or in the lab. The measurement point comes insulated as standard to exclude any falsification of the measurement evaluation through superposition of the offsets. The connection lead permits simple routing up to the measured-data acquisition. Options are available for the probe diameter and wire length as well as the type of connection configuration (plug, socket, bare wire ends, etc.). Temperature range: -100 °C to +260 °C, continuous Wire type: Teflon with CU shielding, Tmax: +200 °C, continuous

Request for a quote

Germany

Verified by Europages

Sheathing thermocouples can be used anywhere due to their ruggedness and small design. Whether in industry, development or in the lab. The measurement point comes insulated as standard to exclude any falsification of the measurement evaluation through superposition of the offsets. The connection lead permits simple routing up to the measured-data acquisition. Options are available for the probe diameter and wire length as well as the type of connection configuration (plug, socket, bare wire ends, etc.). Temperature range: -100 °C to +800 °C, continuous, depending on selected sheathing diameter and measuring medium or atmosphere Wire type: Fibreglass with VA braid, Tmax: +450 °C, continuous

Request for a quote

Germany

Verified by Europages

Sheathing thermocouples can be used anywhere due to their ruggedness and small design. Whether in industry, development or in the lab. The measurement point is hot junction insulated as standard to exclude any falsification of the measurement evaluation through superposition of the offsets. Sheathing thermocouples are freely flexible across their entire length. That means the thermocouple can be integrated in the installation point. The temperature to be measured can therefore be registered near the desired measuring point. A possible connection lead permits simple routing up to the measured-data acquisition. Options are available for the element diameter, element and wire length as well as the type of connection configuration (plug, socket, bare wire ends, etc.). Temperature range: -100 °C to +750 °C, continuous,depending on selected sheathing diameter and measuring medium or atmosphere Wire type: Fibreglass with VA braid, Tmax: +450 °C

Request for a quote

Germany

Verified by Europages

Sheathing thermocouples can be used anywhere due to their ruggedness and small design. Whether in industry, development or in the lab. The measurement point is hot junction insulated as standard to exclude any falsification of the measurement evaluation through superposition of the offsets. Sheathing thermocouples are freely flexible across their entire length. That means the thermocouple can be integrated in the installation point. The temperature to be measured can therefore be registered near the desired measuring point. A possible connection lead permits simple routing up to the measured-data acquisition. Options are available for the element diameter, element and wire length as well as the type of connection configuration (plug, socket, bare wire ends, etc.). Temperature range: -100 °C to +1.100 °C, continuous, depending on selected sheathing diameter and measuring medium or atmosphere Wire type: Teflon with CU shielding, Tmax: +200 °C continuous

Request for a quote

Germany

Verified by Europages

Sheathing thermocouples can be used anywhere due to their ruggedness and small design. Whether in industry, development or in the lab. The measurement point is hot junction insulated as standard to exclude any falsification of the measurement evaluation through superposition of the offsets. Sheathing thermocouples are freely flexible across their entire length. That means the thermocouple can be integrated in the installation point. The temperature to be measured can therefore be registered near the desired measuring point. A possible connection lead permits simple routing up to the measured-data acquisition. Options are available for the element diameter, element and wire length as well as the type of connection configuration (plug, socket, bare wire ends, etc.). Temperature range: -100 °C to +1.100 °C, continuous, depending on selected sheathing diameter and measuring medium or atmosphere Wire type: Fibreglass with VA braid, Tmax: +450 °C continuous

Request for a quote

Germany

Verified by Europages

The central product of WDM Deutenberg are spot-welded wire meshes according to individual specifications. There are four different wire materials used to produce our wire meshes and wire mesh elements: bare wire, galvanized wire, aluminium galvanized wire and stainless steel wire. Our spot-welded wire meshes have different sizes from 300 x 250 mm to 8,000 x 2,400 mm depending on mesh width and wire diameters. Mesh widths between 20 mm x 20 mm minimum and 150 mm x 150 mm maximum and diameters from 2.0 mm to 18.0 mm are possible. The scope of application of our spot-welded wire meshes is very diverse. They are used in industries such as landscaping, agriculture, engineering, shopfitting, metalworking, food industry, electrical industry, construction industry or retail. Please call us for further questions under +49 (0) 38789 / 879-0 an or write us an e-mail to info@wdm-wolfshagen.de.

Request for a quote

Italy

OPERATING TEMPERATURE: MAX 1200°C Resistive filament* of first choice.

Request for a quote

Switzerland

Tin, silver or nickel plated copper Silver, gold, nickel, high strength copper 40 % copper and steel Bronze 6, brass 80/29, nickel 200 Pure silver up to 99,99% Aluminium and aluminium alloys Resistance wires etc.

Request for a quote

Germany

Plastic-coated steel cablestrands are cut to length using a special shear cut module and then stripped with the cutting module of the AM3500 without the wires "jumping open".Bare steel cable wires are transported by the modified AM 3500 directly to the special cutting machine, which is coupled between the AM 3500 and the material stacker and which cuts the material to length by a thermal process. Due to the special electric welding process used here, the individual wires do not twist up during cutting, and a smooth rope start and a smooth rope end without thickening are produced. Long steel cable wires/strands are placed in a tray after processing, while short pieces of material fall down a chute into a collecting container. With the high-performance solution developed by Metzner, the customer can process different types of material in different processes. Further advantages of the machinery are high precision, high quality, an increase in productivity and lower personnel costs.

Request for a quote

United Kingdom

Buy Pure Copper Wire Scrap with a 99.8% copper content. We offer high-quality copper wire scrap for purchase. Our scrap is of the highest purity and is perfect for a variety of applications. Contact us today to get the best deals and prices. Overview Essential details Place of Origin: Germany / Netherlands Brand Name: CRX Model Number: Copper Wire Type: Copper Wire Copper Content: 99.99% Product Name: Pure Copper Wire Scrap 99.8% Copper Keyword: Copper Scrap / Copper Wire For Sale MOQ: 1 Ton Material: 99.995% Pure Copper Shape: Bare Wire Package: Customers' Request Delivery Time: 7-14 Days Wire Diameter: 0.2~3MM Length: Customized Length Supply Ability Supply Ability: 500 Ton/Tons per Week Packaging & delivery Packaging Details: AS BUYER REQUEST Port: USA Lead time 1 - 100 metric tons : 5 days Above 100 metric tons : To be negotiated

Request for a quote

Request for quotes

Create one request and get multiple quotes form verified suppliers.

  • Only relevant suppliers
  • Data privacy compliant
  • 100% free