France, Paris
... replacement Accurate and reliable detection FAST FILIBLE RESULTS Easy-to-read dual-color OLED display EZ reading view from all sides Rotating multidirectional display. 4 Directions 6 Modes, allowing you to view your results in any direction. Automatic shutdown after 8 seconds of inactivity Saves energy and electricity Ideal for sports and fitness enthusiasts Color: blue Brand: Yongrow Model number: YK-80C Size: 62 * 32 * 33 mm...
...The µCAN.8.pwm-SNAP unit is equipped with 8 outputs which provide pulse width modulated signals (PWM) within the range of 0% to 100% for controlling of actuators (valves etc.) PWM output:Basic frequency 40 Hz … 5 kHz Mark-to-space ratio 0.0 % … 100.0 %:Each output to be charged with max. 1.4 A Fieldbus CAN:Protocol CANopen / Raw CAN...
France, Saint-Rémy-De-Provence
...High-efficiency 9 W RGB spot. The LEDs are distinguished by a very long lifespan, lasting up to 50,000 hours, and a very low degradation of brightness over time. Power supply 9V, 9 W for exceptional luminous efficiency. Ensure an appropriate 9V transformer based on the number of spots to be powered. Also compatible with our lighting management systems. Wiring length: 20 cm Spot diameter: 8.5 cm. Drilling diameter: 6.5 cm. Height: 8 cm. 2-year warranty if used with our power supplies. SKU: SN3X3WRGB WEIGHT: 0.212 kg...
France, Rillieux La Pape
... is combined with a very short pulse duration of 8ns, 10 times shorter than a standard fiber laser. The quality of the direct marking is perfect, with no halos or distortion due to heating. It is the ideal solution for applications requiring thin marking and perfect aesthetic results such as the horology and jewelry sectors. VERSATILITY: METAL OR PLASTIC ENGRAVING All types of direct marking...
Germany, Heiligenstadt I.ofr.
... Execution open designs (IP 00, installation max. up to IP 23) Mounting via foot angle Connections: touch-safe terminals high-quality, tropical-grade vacuum impregnation in black polyester resin abrasion-resistant, heat, UV, and solvent-resistant rating plate non-toxic MKP film capacitors Switching group: III0 Protection class: IP 00 Insulation class: B/F Ambient temperature: max. 40°C Frequency: up to 87 Hz, pulse frequency: 8 kHz (typ.) Rated current: range 4 to 90 A Rated voltage: 400 V Protection classes: I...
Italy, Canelli
... screen. Drip-saving nozzle with a two-way valve synchronized with the dosing, pneumatically controlled. Dosing adjustment starting from 20 cc. Container movement on a stainless steel or acetal chain, synchronized with the phases of container introduction and filling. The basic model is equipped with 3 dosing units; however, versions with 2, 4, 6, or 8 dosing heads can be made. No format change is required in the standard version. Hourly production: from 500 up to 6,000 pieces/hour.
Germany, Mauerstetten
... for an input voltage of 24 VDC. It features an internal switching mechanism that toggles the output voltage from the input voltage (= over-excitation voltage) to holding voltage through pulse width modulation at 20 kHz. The duration of over-excitation can be set via a DIP switch to 150 ms, 450 ms, 1 s, 1.5 s, and 2.15 s. Another DIP switch allows the holding voltage to be set to ¼, 1/3, ½, and 2/3 of the input voltage (corresponding to 6 VDC, 8 VDC, 12 VDC, and 16 VDC at an input voltage of 24 VDC).
Germany, Wertheim
... * Version with circulation/washing connection with 3/8" internal thread. * Pumping tube equipped with the original Lutz handwheel. * Examples of media: viscous mineral oils, resins, emulsions, paints, and many other thick materials. Features and Benefits * Uniform volume flow * Easy and quick cleaning * Smooth and low-pulse product delivery * Low wear * Ideal for mobile use * Approved according to the ATEX Directive 2014/34/EU, Category 1/2...
... installation, maintenance-free operation, and long lifespan. They are therefore ideal for OEM applications and demanding laboratory setups. Wavelength: 266 nm Pulse Energy: 12 µJ Pulse Peak Power: 12 kW Pulse Width: < 1 ns Average Power: 8 mW Repetition Rate: Single shot ... 1 kHz Beam Diameter: 0.6 mm Fundamental Mode: TEM00 Applications: Holography, Engraving, Photoacoustics, LIBS, Mass Spectrometry, Photoluminescence, Raman...
Switzerland, Rossens
... drives the Motor Under Test (MUT) at a low speed of 1 to 10 min⁻¹ (respectively 8 min⁻¹ for CTS 103-104) while capturing its no-load torque relative to the angular position. The torque measurement covers a range up to 1 N·m (depending on the selected torque shaft) with an accuracy of ± 0.1 mN∙m (for TS 100 – 50 mN∙m and TS 101 – 100 mN∙m). An executable software controls the system and performs...
... diameter measures 30 mm only, with shaft diameter 4 or 6 mm. The encoder E30 is housed in an ABS plastic case, with axial cable or connector outlet. The output signals can be provided in NPN open collector, push-pull or line-driver format. Supply:5Vdc or 8/24Vdc Output signals:push-pull, line driver Pulses per revolution range:2 to 12500...
Netherlands, Zaltbommel
...The Leadshine 3DM580 driver is a device that converts control commands into pulses applied to stepper motor windings. It is designed for a three-phase stepper motor. Tables for selecting the appropriate operating mode according to the motor model are printed on the driver body. Circuit power: 20-60 V Output current: 2.5-8 A Pulse input frequency: 100 kHz...
Germany, Köln
... V (dc) (4) remote zero input:2-wire, current loop High level:+21 ... +27 V(dc) / ≤8 mA Low level:≤2 High level (pulse >1s):auto zero adjust Degree of protection:IP 30 CE conformity:EN 61000‑6‑2, EN 61000-6-3, EN 61010, 61326-1 & RoHS ETL certification:UL 61010‑1, CSA 22.2 No.61010‑1 Electrical connection:D-Sub, 9-pin, male Without remote zero:two-wire cable plus shielding, twisted With remote...
France, Etupes
...Designation: meter / flow meter Possible bodies: aluminium Seals: viton or PTFE Gears: aluminium Orifices: 1/8’’ - 4’’ Autonomous, mechanical, digital display unit with pulse generator or preselector TECHNOLOGY:Gear ATEX:Yes...
Hungary, Budapest
... (1 to 8 water or gas meters), measurement devices – through IO port. The communicator is providing wireless data transmitting through the Narrow-Band mobile network to the data center. Suitable for answering Modbus RTU request of a Scada system, where it is responsing meter count data towards to the centre. It is also useful for remote monitoring of inputs (external device current status) and for output control (remote switch or gate opening). Easy to configure (remote, local by a free tool), easy to use. The communicator can be accessed remotely.
Estonia, Tallinn
... operating speeds of over 4000 rpm while maintaining enough torque to perform useful work For stepper motor operation with high inertia load, a connector is provided for connecting an external braking resistor. The SMD‑4.2DIN ver.2 driver provides both pulse position control and analog speed or angle control. Microstepping mode - 1, 1/2, 1/4,1/8, 1/16, 1/32, 1/64, 1/128 Control methods: - Pulse position control (STEP/DIR) - Analog speed control (0 ‑ 5 VDC or potentiometer) - Analog control of rotation angle - tracking mode (0 ‑ 5 VDC or potentiometer) - Constant speed rotation...
Belgium, Louvain-La-Neuve
...Pulse Valve, 1/8” & #10-32 Ports See Catalog: Page 166 Additional Information Exhaust hole to atmosphere Max PSI 150 psig Ports 1/8...
France, Racquinghem
... (MOD. 230/260/280): 2,300 – 2,600 mm MAXIMUM WASHING WIDTH: 2,450 mm MAXIMUM WIDTH BETWEEN COLUMNS: 2,450 mm MAXIMUM INSTALLATION HEIGHT (MOD. 230/260/280): 3,015 – 3,315 mm MAXIMUM INSTALLATION WIDTH: 3,560 mm MAXIMUM WIDTH WITH SPLASH GUARDS: 3,800 mm MAXIMUM LENGTH OF THE COVER ABOVE EXIT SIDE: 3,200 mm LENGTH OF RAILS: 11 – 14 m RAIL SPACING: 2,850 – 3,000 mm MAXIMUM POWER USED: 16.0 kW MINIMUM WATER SUPPLY PRESSURE FOR INSTALLATION: 3 bar MINIMUM AIR SUPPLY PRESSURE FOR INSTALLATION: 8 bar...
Germany, Mündersbach
... — Adjustable arc force — Anti-stick function Highlights: — Energy-saving due to high efficiency and standby function — Portable, with shoulder strap — 3.5 m power cable with 16 A Schuko plug — Overvoltage protection: No damage to the device from accidental connection to 400 V mains voltage Weight (in kg): 8 Welding current adjustment range (TIG): 5 A - 200 A Welding current adjustment range (manual): 5 A - 150 A Dimensions (in mm): 428 x 136 x 252...
Switzerland, Reinach Bl
... (HART/PROFIBUS PA/Fieldbus Foundation), 4-wire (HART) Accuracy: Rod Probe: ± 2 mm (0.08"), Rope Probe <= 15 m (49 ft): ± 2 mm (0.08"), Rope Probe > 15 m (49 ft) Ambient Temperature: -40 … +80 °C (-40 … +176 °F) Process Temperature: -40 … +200 °C (-40 … +392 °F) Absolute Process Pressure / Maximum Overpressure Limit: Vacuum ... 40 bar (Vacuum … 580 psi) Wetted Parts: Rod Probe: 316L, Alloy C, Ceramic; Rod Probe: 316, 316L, Alloy C, Ceramic; Coaxial Probe: Process Connection: Thread: G3/4 … G1 1/2, MNPT 3/4 … MNPT 1 1/2; Flange: ASME 1 1/2 … 8", DN50 … DN200, JIS 10K...
... compressed air, pulse-free, water-free, and oil-free Warranty: 6 months on used parts 12 months on new parts Price: upon request Availability: from January 2018 If you are interested, please use our contact form. Delivery is ex works. Our General Terms and Conditions (GTC) apply.
Germany, Pulheim
... Operating voltages DC 5V or 10-24V (also 10 Volt supply voltage for TTL compatibility), up to 8 signal channels, up to 17 output signals (8 + 8 inverted signals + error signal) different connectors or cable exits possible custom designs available upon request...
...Single-jet turbine meter, PTB and EC approval, accuracy horizontal Class B, vertical Class A Water Meter Modularis Single-jet turbine meter PTB and EC approval Accuracy horizontal Class B, vertical Class A Horizontal and vertical installation positions Suitable for downpipe and riser installation 8-digit roller counter with 3 decimal places Optional retrofitting with pulse, M-Bus, or radio module without compromising calibration Parameterization software for radio: F-Tool in the radio product area Water meter: Water meter WZ-M...
France, Toulouse Cedex
... compensated by the increased immunity, which will limit on-site interventions and prevent premature wear of electronic circuits. Don't wait for a disaster that could cost you dearly! The maximum current ratings (I maximum/shock) have been tested with a pulse of 1,250µs in voltage and 8/20µs in current. REF:PSFCN Dimensions:68x105x82mm...
Germany, Thedinghausen
...Argon S8 can be used for all welding positions and all sheet thicknesses. The filling consists of a mixture of 8% oxygen and 92% argon. It is particularly suitable as a shielding gas for MAG welding of highly alloyed, especially rust- and acid-resistant steels. Argon S8 is very well suited for pulse welding. Welding gas according to EN ISO 14175 / MAG process Special features: - very soft, low...
France, Chambly
... signal (e.g., pulse counter) LED operating indicator Model: HYDRA HY.BC Proportional Impulse Frequency Flow Rate: 5 l/h (3 l/h) Pressure: 8 bar (10 bar) Connections: 4/6 mm Frequency: 160 Power Supply: 100 to 240 Vac 50/60 Hz...
Germany, Hohen Neuendorf Ot Bergfelde
... changeover relays 250 V / 5 AAC, 30 V / 5 ADC or 8 PhotoMos outputs (normally open) 30 V / 0.4 A AC/DC Interface RS232 or RS485 galvanically isolated Alternatively to Analog output 2 Power supply 100-240 VAC 50/60 Hz / DC +/- 10% 10-40 VDC / 18-30 VAC 50/60Hz Encoder supply 10 VDC / 20 mA, including digital input 24 VDC / 50 mA, including digital input 24 VDC / 50 mA, including digital input & pulse output, max 10kHz Software features Min/max memory with adjustable permanent display 30 additional parameterizable support points...
...DC Inverter for Plasma Welding The Pi 350 Plasma is a 3-phase, water-cooled DC inverter designed for plasma welding in automatic operation, with a current range of 5-350 A. The pulse-capable Pi 350 Plasma can weld material thicknesses of up to 8 mm for steel and 10 mm for stainless steel, and offers three optional pulse types: conventional pulse, fast pulse, and Synergy PLUS™. Three plasma...
... Dimensions: 7.2x 8 mm (housing, DxL) 1.5x 3 mm (shaft, DxL) Weight: 5g Type: incremental Technology: photoelectric Installation: with full shaft Protection level: IP50 Additional features: compact, miniature...
Popular countries for this search term

The europages app is here!

Use our improved supplier search or create inquiries on the go with the new europages app.

Download in the App Store

App StoreGoogle Play