Belgium, Welkenreadt
... mounting band in the pipe. When combined with the appropriate level sensor, the EMV-500 constitutes an efficient electromagnetic area/velocity flowmeter measuring both velocity and level in the same cross-section (or slice of pipe). This is a requirement necessary for accurate flow rate measurement using the continuity equation: Q = v x A In addition, electromagnetic sensors are totally unaffected by the concentration of debris or dilution of wastewater by rain. Key Features: Accurate flow measurements Grease tolerant: Grease shedding electrodes allow for reliable data collection...
...The branch channel allows for a direct connection or attachment of the facade gutter to the drain. This creates a free cross-section through which water can flow unobstructed. Special features of our branch channels: Our branch channels have a unique slitting. It is designed to make the branch channel flexible. This means that you can easily adjust it to the unevenness of the substrate. Even extreme irregularities can be easily overcome. Cross-section sizes: 5 x 2 cm, 5 x 3 cm, 7 x 2 cm, 7 x 3 cm, 10 x 2 cm, 10 x 3 cm...
...Complete system for continuous determination of silica in a full or partial desalination plant or in the water-steam cycle • Colorimetric measurement method • Complete system with electronic unit, photometer with integrated reaction chamber, flow monitoring, dosing pump for reagents, and reagent containers • 1-channel and 2-channel versions • Max. 6 sample channels with AMI Sample Sequencer...
France, Avignon
...Filtration of polluted drainage water containing hydrocarbons in retention basins under electrical transformers. Flow rate: 50 liters/min pumped Alternative to pumping, transporting, and disposing of waste through specialized channels Extended lifespan, reduced maintenance FILTRELEC® range designed and manufactured in France. Compliant with the requirements of the Water Law, the REACH regulation, and the RoHS directive. Simplicity and ease of use: User manual directly on the product Quick connectors Caps for transport Operable by a single operator...
...Block storage in channels in stationary and dynamic form, optimal for order picking and for order tours.
Germany, Bad Oeynhausen
...The SF filtration system operates continuously and at a constant pressure without affecting the process. The procedure for changing the mesh does not influence the quality of the product. Additionally, the short flow channels – free of dead spots – ensure an extremely short residence time of the molten mass in the system. Type: Continuous Technology: Circular disc...
Germany, Lüdenscheid
... the containers. Division into channels is possible. Suitable for all types of containers (storage view, KLT, EURO containers) as well as cartons and combinations. Variable plug-in system ORION PLUS with tool-free height-adjustable levels at intervals of 25 mm. Construction: Basic shelf, extension shelf Shelf load: 200 kg Warranty: 5 years Surface: Galvanized Shelf width: 1300 mm Shelf height: 2000 mm Shelf depths: 600, 1200 mm System: Plug-in system ORION PLUS...
... gas channels via MFC, Mass Flow Controller (MFC) Pressure measurement: Pirani, Capacitive manometer (for corrosive gas version) Generators: 80 kHz; 13.56 MHz; 2.45 GHz Electrodes: Side electrodes with single or multiple stages Control systems: Full PC (Win.10 IoT) Power supply: 400 V / 50 - 60 Hz Vacuum pumps: One or multiple stages...
...Four-Channel Power Supply / Display + Operates four flow meters, controllers, vacuum gauges, and more + Simultaneously displays four channels with measurement units and gas types + Analog: 0-5 VDC, 0-10 VDC, 4-20 mA + RS-232/RS-485 + Ratio control for gas mixing + Totalizer function...
... periods. To prevent the rotation of the rotary union housing, a locking mechanism is provided, which must be secured with a clamping iron or a long-slot fork. In adjacent channels, the same medium must always flow through to avoid mixing of media in the event of later wear-related leakage. The rotary unions must not be used under maximum operating conditions without prior consultation with the ROTOFLUX customer service.
France, Antony Cedex
... and rotors are forged in one piece... Construction type: Rotary piston blowers Flow rate: 30 to 65,000 m³/h Fluid to be conveyed: air, neutral gases Transport: oil-free. Operation suction: Maximum effective pressure -500 mbar Operation pressure: Maximum effective pressure 1,000 mbar...
Türkiye, Istanbul
... clogging. The laparoscopic irrigation and aspiration system allows for cauterization while simultaneously aspiration or irrigation with Hook options, if desired. Ergonomically designed to be used comfortably in both hands. It has good flow performance thanks to its non-blocking channels. It has a design that will not block the view with its transparent head. - Laparoscopic Reusable - Laparoscopic Disposable - Veress - Laparoscopic Trokar...
Italy, Porto Mantovano (mn)
...Venture River is a water ride of great interest and temptation for children. Its operation is very simple and involves the child turning him into the key player of an adventure on the river while the strong water flow generated by powerful pumps placed in the straight channels carries it along the way. Venture River can be installed in both fairgrounds and fixed amusement parks. It is an...
...The new compact controller MDS-PLCconsists of a touch screen with integrated PLC. It can be operated for 4 independent dosing places/channels. It can be connected to every flow sensors, which can provide a 24 VDC pulse volume. For each dosing place/channel a correction of the overflow will be independently realized and with an adjustable maximum dosing time the valve will be closed. For each...
... in pallets for proper transportation between operations. Side enclosures equipped with all safety measures to ensure safe and healthy transportation are specially designed for the flow of products. MD 25 Bale press Bale Size (mm) : 1200 x 800 x 800 Machine Size (mm) : 1750 x 1255 x 2000 Number of serit channels : 4 Bale striping : String Bale Unloading : Automatic Hydraulic Unit Engine (kW) : 4 Speed (seconds) : 38 Press Power : 25 t Stroke (mm) : 950...
France, Huningue
...Ultrasonic Level Probe for Level and Flow Measurement, Connection to FMU9x (measuring up to 10 m) The FDU91 ultrasonic level probe is designed for continuous, non-contact, and maintenance-free level measurement in liquids, pastes, sludges, and bulk solids. It is also suitable for flow measurement in open channels and weirs. The measurement is insensitive to the dielectric constant, density, or...
... effect is achieved through a kind of rotational effect that forms around the hydraulic center of each flow channel. The guiding elements are arranged on the mixing body in such a way that the four resulting flow channels have significantly different cross-sections in the direction of flow. In addition to layer formation and rotational effects, a shearing flow is introduced, which optimally supports dispersion processes.
Switzerland, Tägerwilen
... with sensors for measuring acoustic and pressure signatures, as well as environmental information such as water flow vector, temperature, and conductivity. The sensor system also includes DGPS, enabling it to track target trajectories with high precision. All signal channels can be read and visualized almost in real-time. Type: Electrical Engineering...
...The oven specially designed for bakeries who want productivity, quality product, homogeneous baking characteristic and more energy saving To ensure long term usage, oven burning chamber is produced by stainless steel Air flow channels are adjustable that inside of the baking chamber. So hot air reach equally to all surfaces and obtains equal baking, regardless of up or down floor, right or left...
Austria, Krems An Der Donau
... and multi-location storage »Simple to multi-depth solutions »Integration of flow channels »Highly economical silo constructions with multiple device levels »Storage of cartons and boxes with varying dimensions...
Germany, Heilbronn
...With over 53,000 square meters of logistics space, there's plenty of room for storage: Our various halls can accommodate warehousing for more than 27,500 pallets of different sizes, as well as nearly 100,000 compartments in the small parts warehouse. Whether it's block storage, pallet spaces, manual or automatic high-bay storage, flow channels, or various types of small parts storage, we can offer the right type of storage tailored to your needs. Your goods are securely stored with us. For confidential files and documents, we provide secured rooms with access control and special monitoring.
... steps are reduced by 50%, as are VOC emissions; our contribution to protecting people and the environment. Your benefits: • Optimization of surface quality by 40% compared to RTM-Light components with barrier coat • Reduction of VOC emissions by 50% • Increase in productivity by 25% • Significant reduction in rework • Achievable at 20°C in the simple RTM-light process Common fiber print, shrink marks from metal inserts, and flow channels are eliminated.
France, Bondoufle
...The high-efficiency cyclone is commonly used to separate the larger particles contained in the suction air or to delay the filling of the upstream filter as much as possible, thus avoiding costly interventions. The cyclone is constructed from robust varnished steel sheet and is complemented by circular channels that serve the principle of centrifugation and a container for collecting materials...
Germany, Kierspe
...All Measurements! Total flow measurement of permanent magnets and magnetic systems Precise Measurement: 0 Drift Resolution: 0.01µVs Accuracy: ±1.0µVs Precise measurement and display of pulses up to 5kHz Easy Handling: Automatic drift compensation Probe identification Self-calibration Creative Technology: 1-3 measurement channels...
Türkiye, Istanbul
... cumbersome work or user-induced openness, which is also the case with sliding dull doors. This special design creates an air gap barrier between the inner and outer curtain system. It maximizes heat and sound efficiency. Automation is compatible with all kinds of automation systems according to the traffic flow of the workplace. Thanks to its special design, Paw-Izo high-speed doors work quickly and intensively in rooms where low pressure area control and sound insulation are required, minimizing...
...MHD series weighing units with modern and flexible design meet many production requirements with different mounting and application types. The scales, which have a polygonal shape, are divided into independent sections. Depending on the production requirements, the number of departments can be between ten and twenty. The product follows the path of the main distributor, flow channels, feeding...
France, Rueil-Malmaison
...Extract the small elongated pieces from the green bean flow. Capacity: 500kg/h to 3t/h depending on the model and size of the green beans. Vibrating system mainly consisting of a vibrating trough with alignment channels and adjustable length holes, as well as upper screens. Also separates small heavy waste and gravel. Optional perforated upper screens based on the sorting characteristics to be achieved.
...Small centrifugal pumps of the KC series are ideal for conveying very liquid fluids. They operate on the principle of side channels and automatically self-prime after an initial filling. Impellers: open / peripheral Fluid: industrial use, cooling emulsions, fuel oil Volumetric flow rate: up to 45 l/min Head: up to 45 m Pumped product: for industrial waters, for cooling liquids, for diesel Drive: electric Priming: self-priming Technology: side channel Sector: industrial Other features: single stage, mechanical seal, suction, miniature...
Italy, Imperia
... shell made of expanded polystyrene with channels for air flow and recycling. Features luminescent external lamp clips for nighttime visibility or in dark environments, compatible with all headlamps available on the market, made of high-tenacity nylon. Soft polyethylene headband, attached to the outer shell without the use of metal rivets. Internal padding made of two separate pieces, headband and disc, completely removable and washable by hand or in a washing machine at 30°C. Hypoallergenic and breathable fabric.
Germany, Kirchentellinsfurt
...Hydraulic Diagnostic Device LR SMART TECH Model HD01 LR SMART TECH Hydraulic Diagnostic Device HD01. 2 channels, each channel measures pressure, flow, and temperature. Data storage, USB interface (data storage as CSV file). Measurement range PRESSURE-FLOW-TEMP.: 0...400 bar-15...300 l/min-0...125°C...
Popular countries for this search term