... poisoning ● Long lifetime ● Pump current switch type, conventional switch type, air-fuel ration type, and wide range type are available Appliaction: Plate Ceramic Heater Chip for Automobile / Oxygen Sensor High Temperature Insulation Resistance: :@800℃,≥1 MΩ Operating voltage::7V - 14V Light-Off Time: :≤10 s voltage: :3.7-220V Heater Resistance: :2.1Ω±0.5Ω Dimension(L*W*H)::Customized...
France, Chateaufort
...The O2 Trace Balise measurement unit is designed for measuring gaseous oxygen and dissolved oxygen. For user safety, a CO2 sensor allows for monitoring the ambient CO2 levels during on-site interventions. Robustly designed, the IP 54 case enables the use of this unit in humid environments. Two automatically changing scales allow for tracking the evolution of oxygen levels across the entire...
Germany, Seligenstadt
... ... Package includes: — Oxygen analyser — Power cable — Hose set, 3 m, incl. filter and probe — Calibration certificate — Transport case Measuring range:5ppm - 21% O2 Ambient temperature:0–45° C Measuring accuracy:+/- 0.3mV (EMK sensor) Heat-up time:3–5 min Response time:approx. 2 sec. for changes Dimensions (L x W x H):180 x 210 x 85mm without handle Mains voltage:100-240V AC Heating cycle load:approx. 40VA Standard load:approx. 20VA Weight:2.1kg...
Germany, Thierstein
...The industrial pressure transmitter DMP 335 is based on a stainless steel welded pressure sensor without fluid. This characteristic has a special advantage with applications where silicon oil or elastomeric seals cannot be used. Features: — nominal pressure: 0 ... 16 bar up to 0 ... 600 bar — accuracy: 0.5 % FSO — suitable for oxygen applications — insensitive to pressure peaks — high overpressure capability Optional Features: — IS-version Ex ia = intrinsically safe for gases and dusts — customer specific versions...
Germany, Wesel
...O2.sens (oxygen Sensor) Measuring range:0-100 Vol.-%, 0-25 Vol.-% Response time (t90):15 s; (5 s als automotive Version) Service life:approx. 5 years...
France, Huningue
...Memosens Amperometric Oxygen Sensor for Water, Wastewater, and Utilities The Oxymax COS51D is a reliable and highly accurate oxygen sensor for all types of water and wastewater applications (including in explosive areas). Designed to require minimal maintenance with a long lifespan, it is exceptionally cost-effective. Thanks to Memosens digital technology, the Oxymax COS51D combines maximum...
...Oxygen Analyzer The compact zirconium oxide analyzer is used to measure percent (0-25%) oxygen in combustion processes. The probe is made of 316 stainless steel and can operate at temperatures up to 400 °C. Sample gas in sensor chimney or furnace. It measures inside and works without the need for an air reference. Easy assembly with flue apparatus and is long lasting.
... that typically cause offsets and premature failures of most oxygen probes. Furthermore, the unique secondary 100% zirconia seat serves as a shock absorber and provides an extremely robust mechanical design that can handle repeated temperature cycling and mechanical stresses without damage.
Germany, Duisburg
... direct connection via standardized fieldbus from the sensor to the process control system. The SMARTPAT sensor stores all data and sends it in a bidirectional digital format via 4...20 mA / HART® 7 protocol to control and asset management systems, portable devices, PCs, and other peripherals. Measuring:: pH; conductivity; ORP; dissolved oxygen Other features:: for liquid analysis Approvals:: IECEx, ATEX, NEPSI, (zone 0)...
... whether it's laboratory scale or industrial process), low-maintenance, and extremely easy to use. Depending on the application, BCP sensors can be ordered with aluminum or plastic housings. Technology: Galvanic Cell Additional Features: Process, Inline Category: Oxygen Sensor...
Germany, Bergneustadt
France, Poissy
...Standard Reference CLD method for low & ultra low NOx measurement, IRGFC for CO, CO2, SO2, N2O, NOx, HF, HCl, TOC and O2 in a single analyse. Fast and simultaneous measurements of up to 10 gases. • measurement of dry and corrosive samples • unheated sample line • intrinsic security with onboard residual H2O measurements • onboard oxygen measure for environmental reporting • highly accurate, excellent stability with automatic optical stability check...
United Kingdom, Accrington
... maintenance-free for 12 months at a time or longer. Optical dissolved oxygen (DO) sensors have largely replaced electrochemical sensors (Clark cells) due to their greater reliability and reduced maintenance requirements. The flexibility of the OxySense line, combined with the knowledge of treatment processes and the experience gained by the technicians at Leafy Technologies, allows for the configuration of the analyzer to meet the specific needs of each facility.
Germany, Köln
...providing comprehensive RGA software with no concerns about operating system compatibility. The single-sensor version of FabGuard Explorer is a cost-effective solution to operating one Transpector ® RGA. With the software’s multi-sensor version, you can control multiple, different types of Transpector RGAs from a single computer. FabGuard Explorer allows for control of both Transpector MPH and...
...The measuring probe is in the form of the lance (KSK-I01a) with a length of 2000 mm and includes a single oxygen sensor at the tip of the lance pushed in compost. The lance tip has a rounded head, so as pushed in, it does not poke through compost components. Oxygen sensor implemented on the basis of ZrO2. The device also available mounted on a ventilation duct compost pile (KSK-I01b with a length of 197 mm) The sensor mounted in this version using the threaded flange M18x1.5.
...Monitor for continuous measurement of dissolved oxygen in ultrapure water, feed water, steam, and condensate Ready for use on a stainless steel mounting plate: • AMI Oxytrace transmitter in a sturdy aluminum housing (IP 66) • Flow cell made of acrylic glass with needle valve and digital flow sensor made of stainless steel • Swansensor Oxytrace G with 3-electrode system (cathode, anode, and guard) and integrated NT5k temperature sensor • Factory-tested complete system...
... times of t90 or t99 of approx. 13 s or 30 s. Oxygen, pH and redox can be determined in parallel. The sensor systems have integrated transient monitoring. Languages and units of measurement can be parameterized. The handheld measuring device is particularly suitable for measurements on hot and steam boiler systems, in district heating systems and power plants. kind of sensors:oxygen and pH/redox...
France, Lannion
...IDIL Fibres Optiques offers a complete range of fiber optic sensors with Fiber Bragg Grating (FBG) or Brillouin effect: - temperature sensor - pressure sensor - strain and deformation sensor - CO2, Oxygen, pH sensor... IDIL Fibres Optiques provides comprehensive solutions for static and/or dynamic measurements with FBG optical interrogators that can adapt to various applications and sensors...
Switzerland, Reinach Bl
...The Oxymax COS22D protects your products, processes, and equipment from the effects of oxygen. It is reliable and stable across a wide measurement range, helping you to better monitor and control your applications. The sensor requires minimal maintenance and ensures long-term stability—even with frequent sterilizations and autoclaving. Thanks to Memosens digital technology, the COS22D combines maximum process and data integrity with simple operation. It allows for laboratory calibration and facilitates predictive maintenance. Technology: Amperometric Other features: Process...
Germany, Herrsching A. Ammersee
... technology based on a novel sieve bottom. In combination with advanced vortex technology, the efficiency of the PSA technology used to separate the oxygen molecules from the nitrogen molecules is drastically increased. Less compressed air is needed in this regard. Extracting more oxygen with lower compressed air requirements means lower energy costs for your business. All operating values are measured and recorded using state-of-the-art sensor technology. This enables continuous monitoring and control of our fully integrated IMT POC oxygen generators.
... Display:Illuminated LCD Display pump:Diaphragm pump, flow rate adjustable and monitored Sensitivity:1 ppm Measuring ranges:1ppm - 2.2 vol.%, 100% LEL, 0-100 vol.% CO2 + CH4, 0 to 500ppm CO Sensor :Semiconductor sensor, Infrared CH4 and / or CO2, Electrochemical sensors Gas Types:Natural gas, carbon dioxide, carbon monoxide, oxygen, hydrogen sulphide Protection class:IP 54 Ex protection:EEX ib d...
Austria, Weitra
...Oxygen sensor with integrated temperature sensor for measuring dissolved oxygen Features • Galvanic principle oxygen sensor, mounted in a robust immersion housing • Measurements independent of flow • Calibration possible in air or in air-saturated water • Long lifespan • Direct insertion into open water or water basins possible • High cost efficiency • No defined flow required Applications • Process control • Wastewater monitoring • Drinking water monitoring • Aquaculture...
...In Situ Oxygen Sensor Brand: SETNAG ADVANTAGES: Excellent response time due to the use of the miniaturized MicroPoas® zirconium dioxide sensor. High reliability and easy commissioning, as no calibration gas is required. Outstanding measurement repeatability for perfect control of your processes. MEASUREMENT PRINCIPLE / FUNCTIONALITY The TTH sensor is immersed directly in the gases to be...
Germany, Hamburg
... configuration with a low oxygen sensor can be used for monitoring imports and exports in thermal power plants and deaerators; it is also utilized in sewage treatment plants for monitoring process points. ● Patented constant potential tri-polar measuring electrode, which enhances the stability of the electrode sensing result and improves the accuracy of the entire testing system; ● Optically...
...Oxygen combination sensor with built-in type S thermocouple and threaded connection. Applications (examples): The sensor is used, for example, in carburizing plants to control the C-level, in forging furnaces to control the air supply of the gas burners, or in the atmosphere of crematoria. The sensor is not heated. Therefore, a minimum operating temperature of 500 ° C is required. Material...
Austria, Olbendorf
...optical measurement sensor for dissolved oxygen...
Germany, Gießen
... transfer between a fluorescent chromophore and oxygen molecules. Since polarization is not required for fluorescence quenching, optical sensors are ready to use and measure immediately, allowing you to focus on what truly matters: the actual process.
Austria, Wien
... transfer between a fluorescent chromophore and oxygen molecules. Since polarization is not required for fluorescence quenching, optical sensors are ready for immediate use and measurement, allowing you to focus on what truly matters: the actual process.
...*High resolution 8.4 ”Touch Color Screen. * Internal Ventilator * Tidal Volume 15ml -1500ml * Mode: Two Gas Machine with -VCV, PCV, SIMV-CV, SIMV-PC, PS * O2, N2O and Optional Medical Air * Ventilator parameters Monitoring TV, MV, FiO2, I: E, Ppeak, Pmean, Pplat, Freq * Flat Absorbent Aprox with Co2 Absorption Canister. 1500ml *Frequency. 4-100 BPM * I: E 4: 1-1: 10 * Alarm Settings TV, MV, Fio2, Ppeak, Alarm Mute * Oxygen Sensor with Fio2 monitoring * O2 and N2O Emergency Cylinder Yoke. * ACGO - Auxiliary common gas Outlet. * AX400 2 Gas Anesthesia Workstation...
Popular countries for this search term

The europages app is here!

Use our improved supplier search or create inquiries on the go with the new europages app.

Download in the App Store

App StoreGoogle Play