Germany, Oestrich-Winkel
... 265 V/AC / 47 – 63 Hz or 120 to 375 V/DC. Increased temperature range up to 70 ºC with derating. High efficiency due to modern circuit technology. Safety certifications: UL 60950-1 2nd, CSA C22.2 No. 60950-1-07 2nd, TUV EN 60950-1+A11+A1+A12+A2, IEC 60950-1+A1+A2, approved. Item No: 510231_101891 Manufacturer No: SPS-070-05 Number of output voltages: 1 - Single Application: Industry Output connection: Screw terminal Design: Enclosed power supply Input connection: Screw terminal Protection class: Protection class I Usable in region: Europe, USA / Canada...
France, Fontaines Les Gres
...Single-phase primary switch-mode power supply in a metal housing. Closed version with screw terminals protected against accidental contact. Overload protection through current limitation, automatic recovery. Protection against short circuits, overloads, and surges. LED display for power indication. For mounting on symmetrical DIN rail. Reference: 82100-10 Protection index: IP00 Protection class: I Standard: UL508, TUV EN60950-1, CE Connection: Protected screw terminals Mounting: Mounting on DIN TS-35/7.5 or 15 rails Temperature range: -10°C to +70°C...
... protected from short-circuit and overload. The short-circuit current is limited by the output transistor switching off inthe event of a fault. It will automatically reset as soon as the fault has been remedied. The switch is available with ground-connected, plus-connected or potential-free DC switching output. The switch is open in the event of power failure or disconnection of the power supply, independed of the switching function. It is available both as normally open (NO) or normally closed (NC) switch.
Germany, Heiligenstadt I.ofr.
...-grade vacuum impregnation in black polyester resin printed performance data with circuit diagram Devices are overload and short-circuit proof due to built-in... Input Voltage: AC 220/230/240 V or AC 380/400/420 V Switching Group: Ii0 with screen winding Output Voltage: SELV DC 24 V according to EN 61131-2 Protection Class: IP 00 Ambient Temperature: max. 60°C Frequency: 50-60Hz Power Range: 72 W - 192 W Residual Ripple: < 5% Emissions: EN 61000-6 -3/-4, (Class B) Immunity: EN 61000-6 -17-2 Protection Classes: I...
Germany, Hofheim Am Taunus
...on and off delay, and hysteresis can be freely set within the measurement range. Switching points: -20 ... +125°C, adjustable Connection: G ½, G ¾ AG, ½", ¾" NPT stainless steel Display: 3-digit LED Electrical connection: M12 x 1 connector or cable Power supply: 24 VDC Contact: 1 or 2 semiconductor PNP/NPN, normally open or normally closed adjustable Accuracy: ±0.5°C (-10 ... +85°C)...
...Input Voltage: 90 - 250V 50/60Hz Input Current: 5.2A (100V) / 2.2A (240V) Output Voltage: 24V DC (adjustable between 24 - 28V) Rated Output Current: 20A Efficiency: 0.96 (230V) Ripple Voltage: < 50mV rms Power Failure Bridging: > min. 30 ms Protection Measures: Short-circuit and overload proof Temperature Range: -25 to +60°C Dimensions (H x W x D): 125 x 85 x 138 mm Weight: 1.38 kg • Single...
... measurement function, automatic shut-off, Lo/Ok/Hi check weighing - Sturdy ABS housing - Large stainless steel platform cover - For non-legal-for-trade weighing - High resolution of 30,000d Power Supply: - Battery operation, operating time approx. 100 hours in continuous use, charge level indicator - 230VAC mains/charger Technical Data: - Large stainless steel platform approx. 315 x 220mm - Large LCD display, backlit (6-digit, 30mm high) - Temperature range: -10° to 40°C - Dimensions WxDxH approx. 322x345x112mm...
... - Power supply: 9-16V DC - Quiescent current consumption: 5mA - Maximum current consumption: temporarily up to 5A possible - Operating temperature: -40°C to +85°C - Reception frequency: 433.92 MHz - Switching current: 1x 10A, 2x 5A, 1x 150mA - Many functions programmable Flexible to adapt to many requirements through various wiring options. System range approximately 30-50m (dependent on environment and antennas).
Germany, Villingen-Schwenningen
... be installed in very restricted space. ESM for DC-brakes: The module keeps the voltage supplied to the electromagnetic device at a constant level over a wide input voltage and temperature range. Full operating voltage is applied to ensure fast switching when the load is switched on. The module then reduces the power supply to constant holding voltage. A 30% reduction provides power savings of...
Liechtenstein, Balzers
... absolute switches (relative to vacuum) or as differential switches (relative to the environment). Features • Corrosion-resistant stainless steel design • Robust design, cleanroom compliant • Easy installation with factory preset setpoints or adjustable on-site Specifications • IP 44 protection • Relay output with potential-free contacts • Highly accurate temperature-compensated sensor • Pressure range E-9 mbar … 2 bar Typical Applications • Atmospheric pressure detection in all vacuum applications • Pressure-dependent switching lock (power supply, gas supply, pumps, ...
... Volts / 50 … 60 Hz Power consumption: approx. 20 Volts Measurement range conductivity: 0.05 μS/cm to 10 μS/cm or 1 μS/cm to 1 mS/cm Limit value conductivity: parameterizable within the measurement range Control of discharge valve: potential-free contact, optional relay for switching the supply voltage for the discharge valve...
... between 2-8 Bft. is possible, and the signal storage time can be selected between 1-15 minutes - Heated sensor surface - Flexible mounting Power supply: 24 V DC / 0.2 A Protection class: IP 54 Temperature range: -20°C ... +60°C Housing: Polycarbonate Dimensions (W x H x D): 85 x 100 x 400 mm Weight: 2.00 kg...
Germany, Bamberg
...Motor starter systems for motor-close and decentralized use in harsh industrial environments Supply voltage at AC 50 Hz: 400 V Rated operating current of the motor: 4.0 A Rated power of the motor (min. - max.): 0.09 - 1.5 kW Number of inputs/motor outputs: 3/1 Switching frequency (max.): Application-dependent Protection class: IP65 Mounting direction: Horizontal and vertical Ambient temperature: -20 to +40° C AS-Interface specification: V3.0 Motor protection through thermal motor model: Yes Approvals: CE Feature: Frequency range podis®/gesis® MCU: 50-60 Hz podis®/gesis® MSS: 50 Hz...
...The AD813ARZ-14 is a high-speed, low-power video amplifier module from Analog Devices Inc. It is designed for use in video applications such as video switching, video distribution, video signal processing, and video signal conditioning. It features a wide bandwidth of 100 MHz, a low current supply of 4.5 mA, and a slew rate of 250V/µs. It is available in a 14-SOIC package and operates over a...
Germany, Mönchengladbach
... output current range:4-300 A (Stick electrode: 10-250 A Maximum no-load voltage:58 V Rated duty cycle:40 % Degree of protection:IP 21 S Switching steps:without steps Number of welding conditions:30 Operating temperature range:-10 - +40 °C External dimensions (WxDxH) in mm:250 x 640 x 395 (without the carrying handle) Mass:30 kg Starting method:High frequency start / "Lift-ARC"...
Slovakia, Sastin-straze
Processing: - Assembling of electronic circuits complete process - SMT surface mount thecnology and AOI inspection Appliance Sectors: - Inverters, Power switching supply, welding, power generators controller - Household appliances - Temperature control for heating and ventilation - Automatic gates and doors - Controls and systems for security Capability range: Forming thru-hole...