... unit can be easily integrated into fully automated systems and meets all requirements for modern dispensing processes. With a built-in power supply, the eco-CONTROL EC200 2.0 offers a compact solution. The control unit also provides options for pressure and temperature monitoring, along with 100 program memory slots. It allows for quick and clear storage of programs. Integration into large systems with PLC is possible.
Germany, Thierstein
... the level, which converts the temperature signal into an analog signal of 4 ... 20 mA using 2-wire technology. Features: — Nominal pressures: from 0 ... 4 mH2O to 0 ... 250 mH2O — Nominal temperatures from 0 ... 30 °C to 0 ... 70 °C — Accuracy: 0.5 % FSO — Diameter 27 mm — Separate output signals for pressure and temperature ranges — Excellent long-term stability — Easy handling — Low maintenance and wiring effort Optional features: — Various cable materials — Various sealing materials — Custom designs...
Germany, Kamen
...Temperature control of liquids Tube coil heat exchangers (so-called tube cooling coil heat exchangers) are generally used to control the temperature of liquids. This system can also be used to heat or cool liquids in a controlled manner. Due to their special shape, pipe coil heat exchangers are sometimes also called hairpin heat exchangers. Inexpensive applications The simple and solid...
...The high-temperature sliding regulation valve type 8023, designed with reinforced GS3 and a NAMUR interface for mounting a universal positioner, finds its applications in a wide range of process regulation tasks up to a temperature of 530 °C. Fluids such as steam, liquids, gases, etc., can thus be perfectly controlled even in high-temperature ranges. This valve is also ideally suited for...
Switzerland, Ebnat-Kappel
...Thick- and thin-film technology for precise heating of solids, liquids and gases - Micro heaters are used in devices requiring a small but accurate heat source with precise temperature control, such as optical interactive assistance systems. Allowing for targeted heating of tiny spaces, IST AG micro heaters are found across various industries, including automotive, laser manufacturing...
Germany, Heinsberg
... resistance moisture measurement, as well as two TS910 contact temperature sensors. Therefore, the DL200P can be used for a wide range of monitoring tasks, such as silo monitoring and bulk material control or for temperature testing of water-based liquids. Furthermore, the logging capability of the DL200P during construction drying and water damage remediation allows for comprehensive documentation for...
Germany, Rain
...tank farms or silo systems. We check and control among other things the compatibility of the substances, the effect of environmental influences as well as the conformity with legal requirements. We ensure compliance with various regulations such as the German Water Resources Act (WHG) or Explosive Atmospheres Directive (ATEX) by means of temperature-controlled storage tanks and the blanketing of the relevant substances by means of nitrogen, dry air or gas displacement systems or their circulation via agitators or circulation.
... different flow sizes, from 10, 13, 19, 25 to 31 millimeters, making it suitable for any conceivable application up to 100°C. For temperature control systems with higher temperatures, MOULDPRO also offers an EPDM hose rated for up to 164°C. Additionally, three colors are available: blue and red, for example, for cold and hot liquids respectively, and a black version.
Germany, Bad Urach
...Blocking valves control the opening and closing of piping systems. They control the inlet, flow or outlet of liquids and gases. Flow valves regulate the volume flow of the fluid used. We have throttle valves, throttle check valves, check valves and stopper valves. Furthermore we offer quick relief valves, toggle lever valves, compact pressure controllers and functional connectors. All mentioned blocking and flow valves are available in various sizes, materials, and pressure, flow and temperature ranges.
...FSA Quality: Motorized ball valves made of brass for irrigation, with stability against a variety of liquids. Control: A detailed manual is included in the delivery. Further information on control is available in the lower section. Advantage of the motorized ball valve: Low power consumption, high flow rate, 3-way variant available. Application areas: Switching speed is not critical, suitable for...
Germany, Großbettlingen
... nozzles. - When opening the compact safety filling screw with the included hex key, excess pressure is released through the recess integrated into the screw. Technical Data: Suitable for a variety of liquids - Fluid Group 1 Max. 6 bar container overpressure allowed Standard design 1 bar (safety valve) Valve voltage 24 VDC, 230 VAC available on request Valves with manual override Seal materials highly resistant Permissible temperature: -10 to +50 °C Volume: 500, 1000, and 2000 ml Optional with float switch...
Germany, Mittenaar-Ballersbach
...Pest Control Hose, Vine Spraying Hose This multi-layered PVC pressure hose in high-pressure design (HD) is specifically suitable for use as a pest control hose / vine spraying hose. In general, it is also suitable for the transport of water, pesticides, insecticides, slightly alkaline liquids, seawater, wastewater, and mineral oil-containing liquids. Temperature range: from -20°C to +60°C Inner core: Soft PVC, black, smooth Outer cover: Soft PVC, blue, smooth (DN 19 outside black with red stripe) Reinforcements: 2-layer polyester fabric with intermediate layer...
United Kingdom, St Leonards-On-Sea
... steel, both having stainless spindles & they can have stems and seals in differing materials to suit the media being used. Each bank of the valve is pneumatically independent but linked by a common central spindle, enabling separate air paths to be controlled concurrently; each output is effectively a valve. The RSV (once also known as the PIV or Pneumatic Interlok Valve) can incorporate an integral electrical rotary switch which allows fluid & electrical circuits to be controlled simultaneously or can be used simply to provide positional indication remotely at the control centre. ...
Spain, Nigrán-Pontevedra
... preserving the quality and safety of food products. Constructed from AISI 304/316 stainless steel, the autoclave offers a range of diameters and lengths to accommodate various client requirements. It features the possibility of adding internal traction for the carts, streamlining the sterilization process and easing the workload for operators. Additionally, heat exchangers are made from high-quality Inox or Titanium, ensuring efficient temperature control and durability. Tailored to enhance the sterilization of products requiring gentle agitation, this autoclave represents a significant advancement...
Belgium, Anderlecht
... service, no need for a specialized refrigeration technician. Self-thermostatic temperature, maximum working ambient temperature of 24°C, digital control thermometer. Easy maintenance, removable stainless steel hopper and neck. Low voltage controls 24V, with reverse operation, waterproof electrical box (IP54), NVR (No Voltage Release) preventing any unintentional starts. Powerful and ventilated motor (for intensive use), equipped with thermal protection. Hermetically sealed oil bath reducer protected against liquids with a double insulation system. Reference: TB32/ICE Brand: Diamond Europe...
Germany, Neuenrade
...CSN ® Explosion proof cartridge heaters as direct heaters for liquids or gases in hazardous environment. These units are equipped with a heating bundle or a replaceable ceramic heating element. For temperature control these heaters are available with an integrated temperature monitoring system. These devices are available in various material grades. The electric cartridge heating element type 93...
...The NPACK drum liquid weighing filling machine is a piece of packaging equipment used to weigh and fill liquids into 100L to 300L drums. A weighing platform (weighing system), a filling nozzle or several filling nozzles, a control panel, and a roller conveyor system comprise the majority of the equipment. The weighing platform measures the weight of the drum before and after filling to ensure...
Germany, Duisburg
... characteristics::TDR guided wave radar Medium::for solids Applications::for tanks Measuring range::up to 20 m / 65.6 ft (liquids) and 10 m / 32.8 ft (solids) Process temperature::up to 100°C / 212°F Pressure::up to 16 barg / 232 psig...
Spain, Montmeló
... integrated bypass function allows for efficient fluid circulation, while the heating system ensures the optimal temperature of the pumped liquid, preventing cooling or solidification of the product. The combination of the ATEX motor reducer and the integrated heating guarantees safe and reliable performance. This pump group is ideal for handling viscous liquids, oils, and sensitive chemical products. Its robust design and durable structure make it a safe and efficient choice for operations under demanding conditions.
Germany, Dorsten
...Our air-cooled low-temperature chillers with a capacity of 50 kW are ideal for temporary cooling and freezing applications, delivering consistently low temperatures. Whether for planned projects or urgent needs, we find the right solution for your requirements. Environmentally friendly refrigerant R507. "Cold Liquids" stainless steel page, designed for processing a wide range of thermal fluids...
Germany, Schwerin
... length 90 mm, diameter 18 mm Dynamic smart drive and control DC precision motor with integrated encoder Low pulsation delivery, low shear stress rotary micro annular gear technology, no... Flow rate:0.15 – 9 (min. 0.0015 *)ml/min Smallest dosage volume:0.25µl Displacement volume:1.5µl Differential pressure range:0 - 3 bar (43.5 psi) Maximum inlet pressure:1 bar (15 psi) Liquid temperature range:-20...
Italy, Bedizzole
...The ERW axial systems for industrial refrigeration of process fluids (water, water and glycol) are air-cooled units, utilizing EC (Electronic Control) axial fans. This range includes a series of models with cooling capacities ranging from 2.1 kWf to 595 kWf. Three different versions are planned for different output fluid temperature ranges, agreed upon with the client during the design phase. The entire range uses a refrigerant with a GWP of 631.
France, Mulhouse
...The V928 model is a series of hygienic control valves available in a three-way version with angular or horizontal connections. These valves are designed to accurately regulate and control the flow of liquids and gases, making them suitable for hygienic applications in the pharmaceutical, cosmetic, fine chemical, and food and beverage industries. The V928 model can be assembled with pneumatic...
Italy, Novate Milanese
... to install, adapt easily to all types of piping, valves, and fittings, and are maintenance-free, allowing for precise temperature control through simple thermostats or the use of electronic temperature regulators.
...The Fillmatic E filler is suitable for filling non-CO2 beverages. Thanks to the use of heat-resistant components, the temperature of the liquids to be filled can reach up to 100°C, making subsequent pasteurization unnecessary. For better control of the filling process, the bottles are illuminated with an LED lamp. Once the target value is reached, the control system automatically stops the...
Germany, Oberthal
...In contract mixing, we contribute as your reliable partner and enable you to continue production with minimal fluctuations by taking this important step off your hands. The success of contract mixing different substances and substrates lies in the precise control of all parameters: particle size, volume, density, viscosity, temperature, and much more. We adhere strictly to your specifications...
Germany, Villingen-Schwenningen
...PTS 500 - Sensor for Measuring Pressure and Temperature 2 in 1 Sensor: Pressure and Temperature Media-contacting parts made of stainless steel for universal use in gases and liquids Easy integration into control systems, process control technology, and energy management systems via digital interfaces Modbus-RTU, Ethernet, or M-Bus interface Alarm relay - limit value adjustable via buttons (max. 60VDC, 0.5 A) Optional: 2 x 4…20 mA analog output, 2 x alarm relays for pressure and temperature...
Germany, Betzigau
...• Reliable measurement principle and easy commissioning. • High chemical resistance of the probe. • High sensitivity starting from a DK value of ≥1.5. • Level measurement independent of the container wall or pipe. • Maintenance-free, corrosion-resistant, suitable for a variety of applications. • Approvals for use in gas and dust explosive areas. • Level detection in liquids, sludges, foams...
Germany, Herdwangen-Schönach
...Manual hose reel for water, hot water, oil, and similar liquids and grease This hose reel is equipped with roller windows on four sides, both top and bottom, as well as on the sides to protect the hose. The hand crank of the reel can be mounted in various positions to enable optimal operation. Application areas: Agriculture, industry, mining, lubricant trucks, and transport Type of fluid: Water, hot water, oil, and similar liquids, grease Max. water temperature: 130 °C Capacity: 1/4" 300m, 3/8" 200m, 3/4" 80m, 1" 50m...
...Filtration of aqueous media with automatic and continuous backwash filters Flow rate up to 250 m³/h (based on clean water) Nominal diameters DN150 (optionally DN100, 125, 200) Programmable control Welded, one-piece housing made of 1.4571 Backwashing without operational interruption No moving parts within the system Short flushing times Compact, vertical design Filter fineness nominally starting...
Popular countries for this search term

The europages app is here!

Use our improved supplier search or create inquiries on the go with the new europages app.

Download in the App Store

App StoreGoogle Play