...Forced Ventilation Units Forced Ventilation Units type MW in IP 66 with axial ventilation fan to ensure a low run at a simultaneously higher output. These units can be operated at a higher ambient temperature of max. 60 °C.
Türkiye, Sivas
...which consists of essential components such as a thermostat, fan, and evaporator, provides cold air to the area that needs to be cooled, transforming it into a cold room or cold storage. The other main part of split cooling devices is the outdoor unit. The outdoor unit also contains a fan. In addition to the fan, there are components such as a condenser and compressor. The outdoor unit expels the warm air it has taken from the area to be cooled outside. This contributes to cooling the indoor area much more effectively and quickly.
...Additionally, with optional moisture conditioning, moisture recovery can also be determined. Other thermal performance metrics include the air volume flow in alternating operation and the balance, which can also be measured using the test stand. The test stand is equipped with an auxiliary fan, allowing for the measurement of continuously operating ventilation units using the direct measurement method.
Türkiye, Istanbul
...FKSF-P is produced for flow rates between 300 m³/h and 3,000 m³/h. They are equipped with 2 G4 dust filters, an active carbon filter, a HEPA filter, an air regulating damper, and a plug fan. The filters feature a sliding mechanism, making maintenance and filter replacement easier. If requested, the interior section walls can be covered with lead plates to prevent X-ray damage.
Germany, Ratingen
...Switchable Operating Modes (Measurement or Control) Switchable Measurement Variables (Differential Pressure or Volume Flow) Switchable Measurement Units (Pa and m3/h or inH2O and cfm) Preconfigured Measurement Ranges Analog Output 0…10V Adjustable k-Factor for Volume Flow Calculation Measurement Mode with Adjustable Threshold Control Mode with Adjustable Setpoint: 2 Setpoints Setpoint...
ufs.country_names.RU, Moscow
...BERNINA MINI Remote Semi Vertical Air Curtain Multideck Chiller Controller: Digital controller with temperature display Cooling: Remote refrigeration \ Integrated refrigeration, fan assisted dynamic cooling system Defrost: Automatic Climate Class: 3 Temperature Range: - 1 + 1 °С, +2 +4 °С, + 4 +6 °С Height:1500 mm Possible widths:938 mm – 3750 mm Depth:970 mm ...
Italy, Milano
AGGREKO is an international specialist in the temporary production of electricity and cooling and heating solutions. Energy production and temperature control solutions are suitable for larger cities and remote locations. AGGREKO works tirelessly to meet your needs for electricity, heating, and cooling at any time! In the design and distribution of generators, cooling or heating systems, dehumidi...
Türkiye, Antalya
... supply: 220V Refrigerant: R32 Product dimensions W/D/H: 1215/500/830 Application Areas Hotel: Designed for integration into pool heating systems. Home: Designed for installation in home systems. Greenhouse: Designed for integration into fan convectors. Building: Designed for integration into underfloor heating systems.
... assembly of the modules to each other is bolted from inside the cell, and neoprene-based sealing gaskets are used at the joining surfaces. The cells are made up of an aluminum profile frame and sandwich panels. Since there is no welded assembly in the manufacturing of the cells, complete disassembly delivery can be made if desired. The service doors have one side hinged and the other side equipped with a special door handle, ensuring complete sealing. Each fan or extractor cell features a special observation window on the service door and also includes a lighting fixture inside the cell.
...GENERAL DESCRIPTION MAKS FAN COIL TABLET is a slow dissolving biocide tablet that scientifically developed to control slime forming bacterias and other undesired biological growths (Fungea, algea, mildew, virus, etc…) in air conditioning systems. PRINCIPAL USES MAKS FAN COIL TABLET is used as part of a planned maintenance program for air handling units in industrial, commercial and medical...
France, Paris
...6 low-energy Plasma coils combined with a three-stage filter system from Camfil® and a five-speed fan. The unit is portable on wheels for spot disinfection protocols. Standalone unit ideal for ultra-rapid sanitation in large high-risk areas. Operating rooms Intensive care units Emergency rooms In vitro fertilization laboratories Patient services Construction projects Childcare / schools Facilities for the elderly...
... drawer model • Front loading • Made of AISI 304 stainless steel • Temperature Scale: -5°/+10°C • Operating Temperature: +2°/+4°C • Power: 800 - 1600 W • Illumination: 36 W fluorescent • Defrost: Fully automatic • Air Flow: Fan controlled • Temperature Isolation: PU Isolation • Voltage: 220-240 V/50-60 Hz • Dimensions of the Double unit (WxHxL): 845 x 2410 x 1970 mm • Dimensions of the Triple unit (WxHxL): 845 x 2410 x 2740 mm -- For more details about this or other morgue units or products, please send us an email or give us a call.
Slovenia, Šempeter v Sav. Dolini
... underfloor heating, radiator or fan-coils. They can be fitted into older and new buildings. You can also combine them with a domestic hot water system and an air ventilation system. TermoPlus produces two ranges of geothermal heat pumps: Terrapump, for use with soil and Aquapump, for use with underground water. Our heat pumps typically pay for themselves within 3.5 years or even less if you receive government subsidies or a grant for the system. Benefits: 1) Incredible efficiency and savings. 2) Function-packed but easy to use 3) Reliable, durable and environmentally friendly...
Italy, Lipomo
...Technical features: forced ventilation and cooling system for warehouse Autonomous ventilation and air supply units complete with: - external air louver section - supply air fan section for ventilation - section prepared for post-heating expansion - filtering section - special version with ATEX components for explosion-risk areas - power and electronic control panel - digital central unit for...
...Liquefaction Unit JDK JHE-D-09, Compressor SC15DLX Danfoss, Refrigerant R404a, Condenser Type KN09 Airflow 1,200 m³/h Fan 1x300 mm Noise Level 55 dB Max. Operating Current 3.7 A Voltage 230V/1F/50Hz Dimensions (AxBxC) 385x540x360 mm Mounting Dimensions (DxE) 355x390 mm and 4 holes x 7 mm Connections 1/2"x1/4" (12x6 mm) Weight 39 kg Cooling capacity measured for condensation temperature/ambient temperature 32°C, Refrigerant R404A, Measurement conditions: EN13215 Cooling capacity (W) at To - 10 °C - 15 °C - 20 °C - 5 °C 0 °C 1150 950 770 1380 1620...
Belgium, Naninne
...The MiNi-SMMs eco combines compactness, performance, and installation flexibility to meet the demands of both the residential and tertiary markets, providing a high level of comfort while controlling energy consumption. Commercial Documentation French Installation Manual French User Manual French Design Manual English Service Manual English Compact dual-fan outdoor units offering up to...
Germany, Eschbach
...Together with a matching Kühligel® the flat cooling units have a height of approx. 12 mm. In other words, they are ideal for compact applications. In order to achieve the optimum size and heat dissipation, customized dimensions and shapes can be realized. The new model with its 0.15 W power input during operation, is extremely economical with regard to its diverse application possibilities. And that’s not all, the new RaAxial fan has aerodynamically optimized blades that have a significant effect on the noise behaviour. The LF40E05 is thus exceptionally quiet. ...
France, Brest Cedex 2
... to water (kW) 62.5 Combustion air flow (L/s) 123 Engine and radiator capacity (L) 27.60 Max water temperature (°C) 110 Fan power (kW) 10.80 Fan air flow Dp=0 (m3/s) 4.30 Available back pressure on air (mm H2O) 12.50 Refrigerant type Glycol-Ethylene ALTERNATOR FEATURES General data Other data Alternator ref. AT01430T Number of phases Three-phase Power factor (cos Phi) 0.80 Altitude (m) 0 to...
Ukraine, Ternopil
...CWT series tanks store chilled water for refrigeration systems, heat pumps, fan coil units, and cooling chambers, especially in systems with limited water content or where production and consumption of cold are time-separated. Some models can alternate between cold and hot water storage for seasonal use in reversible systems. CWT series tanks from Teplobak come in the following versions...
Germany, Wadern
... its screen surface, it is impact-resistant and prevents injuries to athletes. - Cabin with an advanced locking system, signal and power connection, saving labor costs. - The cabin stands upright and is graduated on the ground thanks to its legs, - 4 Fast Fan Cooling units - Low power consumption, Image - Wide viewing angle - Clear image with camera - Advanced high refresh rate, "The image used...
...DITTEN Air Technology Components: Trading company with its own product development and manufacturing. The use of fans and units is something that really needs to be calculated. If the fan performance is too high, you may struggle with drafts. If the units are too weak, there will be uneven air distribution, and you won't be able to supply the desired amount of fresh air to the rear areas of the...
... panels: 2x sliding lock and a key lock and easily detachable Swing handle lock fitted to glass front door and solid metal rear door Full height front and rear adjustable galvanized steel 19” profiles 19” profiles marked with U height position Large cut out in base and roof for cable entry Roof is prepared for fan units (punched out entries)...
... your needs. This equipment is available in standard or ATEX versions. The main advantage of these units is that they comply with current regulations for indoor installation. Equipped with multiple options such as explosion-proof vents, frequency converters, fire prevention systems, remote start controls, machine interlocks, etc...
Germany, Nettetal
...Chilled Water Climate Systems: Chillers, Heat Pumps, and Free Cooling in Combination with Water-Driven Fan Coils Chilled water air conditioning systems as an alternative to direct expansion systems. Respond to rising refrigerant prices and stricter regulations with alternative solutions. With MTA chillers and compatible indoor units (fan coils), you benefit in terms of the amount of refrigerant...
France, Bondoufle
...CORAL produces a wide range of air treatment devices. The air handling units stand out for their quality and cutting-edge technology. The air treatment units are suitable for multiple applications, including: - Pressurization with or without heating of painting rooms, drying, maturation, etc. - Supply of clean air / pressurization of sealed rooms and chambers (dust-free) - Heating / cooling...
...Industrial fans as inline blowers for industrial drying, ATEX or recirculation units Fan unit with free-running wheel Designed for pressures from 500 to 3,800 Pa Impeller diameter from 355 to 1,250 mm Variants: - as inline fan - as pull-out - as swing-out - for device installation - special solutions for high-temperature areas in ATEX design...
Germany, Friedrichsdorf
...The units are supplied by a silent, maintenance-free three-phase fan, a cyclone dust filter with a collection container, and a PLC system. This can control up to 8 METRO SG HOS feeders, 8 mixers, and 4 vacuum suction valves. Area: plastics industry Application: plastic granulate How it works: Central transport system Fan capacity: 0.85-4.3 kWh...
ufs.country_names.RU, Moscow
...Electrical and electronic equipment mounted inside a cabinet generate heat that raises the temperature internal air. Over time, the ever increasing heat can cause sensitive devices to malfunctions. Additionally, heat accumulation can cause circuit breakers to trip which can result in system shut down. Fan filter units are used for enclosure climate control to dissipate heat from within the...
Germany, Reutlingen
...Flexible and proven ceiling system with maximum design freedom. All functional elements, such as lighting and filter fan units (FFUs), can be easily integrated. High-quality ceiling system from ap-systems based on the patented aluminum carrier profile. The profile is smooth all around and not pre-perforated. Together with the high-quality sandwich panels and a self-supporting cleanroom wall, it...
Italy, Fraz. Mollaro-Predaia
... flows can be achieved, up to a maximum of 48,000 m³/h. The filters in the Electrostatic Line, model AR, are designed with a robust structure made of bent sheet metal, suitable for floor installation. The units are equipped with an inlet flange for coupling with a fitting to connect to the system's ductwork. The filter also includes an electrical control panel for managing the electrostatic part and, in the case of models with a fan, also the start/stop controls for the suction unit.

The europages app is here!

Use our improved supplier search or create inquiries on the go with the new europages app.

Download in the App Store

App StoreGoogle Play