Germany, Villmar
...Kettner TerraSafe is a modular plastic duct system. Various adapter plates allow for the implementation of a wide range of different sizes of the incoming cable protection pipes. The use of cable ducts saves space while ensuring accessibility to the network node for inspection and maintenance.
Türkiye, Çorum
...The Air Channel is used for cleaning wheat, barley, legumes, and soybeans. The machine separates all kinds of light materials that differ aerodynamically from grain kernels: waste, straw and spike fragments, various seeds, peeled husks, and dust through air flow. While the grain products are distributed homogeneously across the width of the Air Channel via the machine's feeding table or a vibrating feeder, the light particles are directed to the upper outlet channel by the upward air flow, while the cleaned product falls down and is transferred into the system.
Poland, Wola Mrokowska
...ILA maleend flexible duct connectors are used for joining two round SPIRAL or plain ducts. They are most often used for connecting air handling units, heat recuperation units, and duct fans. The flexible duct connector deadens the vibration generated by the equipment to prevent vibration and noise in the ductwork and ensure improved acoustic performance of the ventilation system. The flexible...
France, Ruelisheim
...The 90x40mm duct is a compact and versatile cable management system designed to organize and protect cables, electrical wires, and fiber optics. Made from PVC, this duct features a sturdy construction that ensures durability, wear resistance, and temperature resistance (-15 to +60 °C). The bottom of the duct is pre-drilled to facilitate its attachment using knock-in anchors.
Sweden, Växjö
...A duct fan is an important component in a ventilation system and is used to circulate air through ventilation ducts. The fans are often compact solutions available in both rectangular (box) and circular designs. Of course, there are a variety of material options tailored to application needs. Some duct fans are also specially soundproofed for very quiet operation for installation in, for...
Germany, Minden
...-considered details that provide clear added value to the customer and make work much easier. The visually appealing and intelligent solution for BLOCAN® cable management offers ample space for all types of video, data, audio, control, or power cables as well as hoses. The aluminum cable duct is available in sizes 40, 40x80, 80x40, and 80x80 [mm] and is supplied as bar stock (max. 6m, can be cut to size...
Germany, Hückeswagen
...Single-Wire-System as a safe guide for single cables If you want to group, stabilize, and guide different cables without using a channel, the Single Wire System (SWS) from PFLITSCH is the best alternative to clamps, ties, flexible tubes, or Velcro strips. Its advantages: - Flexible VA rod for stable and flexible guiding - Corrosion-resistant system - Open guide for cables, easy to clean...
Bulgaria, Veliko-Tarnovo
...the diameter must not be less than 3.5 mm; 2. it is made of polyvinyl chloride; 3. The air duct, consisting of a metal needle and an air filter, is made of metal and polypropylene; 4. Filter to prevent the penetration of unwanted particles; 5. Drip chamber with filter provides visually controlled filling; 6. Connection type: Luer Slip or Luer Lock; 7. A metal atraumatic injection needle with a triangular blade, coated with silicone for ease of insertion, with a size of at least 0.8*38 mm (available with and witout a needle . There is a roller regulator for the flow rate. ...
France, Chatillon St-Jean
... 1 mm to 3 mm in diameter) - A band uncoiler that forms the duct - A coating band uncoiler - A hot air welding machine with two heads - A set of guides to shape the metal wire in the duct - A tool for manufacturing the duct with the specified diameter - A set of welding guides - A conveyor belt for evacuating the duct...
France, Poissy
...Controller-based filter dust leakage monitoring system (0 – 100 %) for monitoring filter emissions after bag filters, cartridge filters, cyclones (without TÜV certification). Material to be measured: Dust Technology: ElectroDynamic (latest influence principle) Measuring/monitoring capacity: 0 – 500 mg/m³ Chimney/duct diameter: up to 6 m Process temperature: up to 400 °C...
Türkiye, Istanbul
...Roll Forming Lines can produce a wide range of products. Some of the products you can produce using roll forming machines; Highway Acoustic Barriers, Gypsum Profiles, Cable Trays, Scaffolding profiles, Storage rack profiles, Market shelf profiles, Suspended ceilings, Guard rails, Trapezoidal profiles, Shutters, Hose and duct clamps.
Lithuania, Ilgakiemis
...Company produce flat ventilation system that is easy to mount and hide in wall as well in ceilings. The flat ventilation ducts are made of galvanized sheet metal, heat and damp resistant.
United Kingdom, Manchester
...DuctSeal HG (Water & Gas) is a NEW re-enterable duct sealing system that is extremely flexible in its ability to seal large, heavy cables & pipes in ducted networks to protect and stop the ingress of harmful or flammable gases, liquids, smoke, and vermin. DuctSeal HG comes complete with our PATENT PENDING unique tubular rubber backing system that can be joined together in a long continuous...
United Kingdom, Braintree
...Ductwork Design & Installation - Onsite Ductwork Fabrication A Fume Cupboard Extraction System. should be designed, installed to run efficiently, safely and with the minimum of noise levels. To achieve these requirements all our extract and duct work systems are designed, installed, and commissioned to meet the requirements of H.V.A.C. DW154 (Plastic duct work specification), and B.S. E.N. 14175...
Türkiye, Trabzon
...allowing them to function in various partially open positions. The variability in damper functionality caters to different operating scenarios and provides flexibility in managing the flow of air or flue-gas through the duct system.
...The rectangular duct with a length of 100 cm is an element designed to form a straight section of the rectangular duct system. Rectangular ducts with a cross-section of 150 x 50 mm made of galvanized sheet metal are intended for the construction of a system for distributing warm air from a fireplace or for supplying cool air to a fireplace insert. They are also used in ventilation systems. Ducts...
United Kingdom, Settle
... time with the UV Energy. In addition to the lamp array the Bio-Wall is equipped with a ballast housing which is usually located on the outside of the duct adjacent to the Biowall array on the inside. The ballast box has contacts enabling connection to a BMS system for remote monitoring and switching.
...Interior deck system for the RheinRuhr Express (RRX) The highcapacity, doubledecker local trains developed by Siemens are fitted with an interior deck system from TC. All of the components – middle deck, lowfloor and highfloor haunches, inner side deck and cold air duct – are based on GRP pultruded profiles.
United Kingdom, Birmingham
...AJS supply the highest quality fittings and fixtures needed to complete a full heating, ventilation and air conditioning system. All products are supplied are manufactured by reputable companies who we have built a solid working relationship with and are safe in the knowledge that all products supplied by AJS will be safe and meet all specifications set by regulations such as HVAC DW144. Duct fixtures and fittings stocked include spiral tubing T & Y pieces, bends, branch saddles, cap ends, flanges and couplers to manage the air flow through the ducting and connecting elements of ducting systems.
Spain, Nigrán-Pontevedra
...Tailored to meet the specific production needs of clients, the Tuna Cooking Blancher is an advanced machine designed for the optimal cooking of tuna. It features a lid closure system operated by a hydraulic cylinder, ensuring a watertight seal with a water gutter that prevents steam from escaping, except through a designated duct at the rear. This design not only prevents steam buildup in the...
Poland, Świątniki Górne
... mounting range: The adjustable system allows for installation on openings with diameters from 90 mm to 160 mm, providing great flexibility of use. Slanted protective ribs: Effectively protect against rain, dust, and wind, supporting proper air flow. Insect mesh: Provides additional protection against insects and debris, enhancing comfort and cleanliness in the rooms. Durable and...
United Kingdom, Ilminster
Türkiye, Istanbul
...Omnibus Bar Duct for Lighting (25A) The E-Line KY-S lighting bar duct systems have been designed for buildings and industrial installations that have lighting and power circuits with small machines and electrical equipment requiring three-phase and/or single-phase power with 25A. The KY-S Lighting Ducts, with their 10 to 16 A sockets and 32 A junction boxes, are manufactured by fully automated...
Austria, Aurolzmünster
... concept from Scheuch COMPONENTS reduces odours and significantly contributes to complying with and even undershooting the legal regulations and permissible limits for odour emissions. Depending on the intensity of the odour emissions and the size of the hall, the Scheuch OEC system is equipped with one or more biofilters which extract and clean the polluted air. Microorganisms contained in the filter’s bulk material ensure that odours are eliminated and the air is dehumidified. In a second step, a downstream duct filter removes dust and other particles from the air.
Germany, Weil Der Stadt
...max. size 74 x 106 cm age 2014 5 printing units + coating unit (chamber duct) + extended delivery chamber duct system Harris + Bruno max. 18.000 cycles / h (off-load) Colortronic ink remote control motoric height adjustment with memory QualiTronic ColorControl - inline colour densitiy control QualiTronic Live View QualiTronic small density control strip ErgoTronic Color Control...
Italy, Campo San Martino
... Automatic defrosting and condensation water evaporation. High-seal gaskets, fan stop during door openings. LED light, lock, air duct, multipoint core probe (4 reading points). Multilevel function, SD CARD with video tutorial and USB port for HACCP data export. Optional: Tracer, Supervisor. Range: -10/+45 °C Coating: INOX AISI 304 Gas: R452a Dimensions mm: 803x1016x2090 Maximum shelves: 36 EN600x800 H20 Number of guides: 18 (EN 800×600)...
Spain, Manlleu-Barcelona
... heated. The main advantages compared to other heating systems are: - They do not take up floor space. - Reduced acquisition and installation costs. - Very fast heating system. - Air distribution can be direct, or a duct network can be applied to channel air into adjacent areas where the equipment has been installed. - Combustion efficiency greater than 90%.
... nm, 340 nm, 420 nm, or Lux Refrigeration coils installed in air duct (does not include required refrigeration unit) S 3T Specific Specimen Surface Temperature system WXView (Weather View) Data Acquisition System LiquiAir TM self contained xenon lamp cooling system (top or wall mount available) Chamber air and DI water refrigeration XenoCal irradiance calibration device for independent irradiance calibration and measurement at the sample plane High Irradiance capabilities available with custom rack designs (Ci5000 HE)...
... system components e.g. STRATE AWAaerob ventilation systems, operating data recording and remote transmission etc. One-piece pre-fabricated concrete building, suitable for road and crane transport with four threaded attachment and transport sleeves Re-siting of the service building is possible Inside walls: exposed concrete, painted with washable dispersion paint, colour according to customer wishes Outside walls: textured render, painted in colour according to customer wishes Floor: smooth concrete floor plate with openings for shaft cover, cable duct etc. Housing:Concrete B45, DIN 1045...
United Kingdom, Birmingham
...Duct sanitization system that reduces the microbial load in the air and on surfaces, using tested and certified Bioxigen® technology. Air ducts, and in particular the most critical sections (bends, changes in direction, corners, etc.) are susceptible to accumulation of dust, stagnant moisture, condensate and mucilage that create the perfect conditions for biofilm to form. The consequence is...

The europages app is here!

Use our improved supplier search or create inquiries on the go with the new europages app.

Download in the App Store

App StoreGoogle Play